kicad/eeschema/files-io.cpp

1684 lines
57 KiB
C++
Raw Normal View History

/*
* This program source code file is part of KiCad, a free EDA CAD application.
*
* Copyright (C) 2013 Jean-Pierre Charras, jp.charras at wanadoo.fr
* Copyright (C) 2013 Wayne Stambaugh <stambaughw@gmail.com>
* Copyright (C) 2013-2023 CERN (www.cern.ch)
* Copyright (C) 1992-2023 KiCad Developers, see AUTHORS.txt for contributors.
*
* This program is free software; you can redistribute it and/or
* modify it under the terms of the GNU General Public License
* as published by the Free Software Foundation; either version 2
* of the License, or (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program; if not, you may find one here:
* http://www.gnu.org/licenses/old-licenses/gpl-2.0.html
* or you may search the http://www.gnu.org website for the version 2 license,
* or you may write to the Free Software Foundation, Inc.,
* 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA
*/
#include <symbol_library.h>
#include <confirm.h>
#include <common.h>
#include <connection_graph.h>
#include <dialog_migrate_buses.h>
#include <dialog_symbol_remap.h>
#include <dialog_import_choose_project.h>
#include <eeschema_settings.h>
#include <id.h>
2021-09-14 22:45:14 +00:00
#include <kiface_base.h>
#include <kiplatform/app.h>
#include <lockfile.h>
#include <pgm_base.h>
2023-09-07 11:22:10 +00:00
#include <core/profile.h>
#include <project/project_file.h>
#include <project_rescue.h>
#include <project_sch.h>
#include <dialog_HTML_reporter_base.h>
#include <plugins/common/plugin_common_choose_project.h>
#include <reporter.h>
#include <richio.h>
#include <sch_bus_entry.h>
#include <sch_commit.h>
#include <sch_edit_frame.h>
#include <sch_plugins/legacy/sch_legacy_plugin.h>
#include <sch_file_versions.h>
#include <sch_line.h>
#include <sch_sheet.h>
#include <sch_sheet_path.h>
#include <schematic.h>
#include <settings/settings_manager.h>
#include <sim/simulator_frame.h>
#include <tool/actions.h>
#include <tool/tool_manager.h>
#include <tools/sch_editor_control.h>
#include <tools/sch_navigate_tool.h>
#include <trace_helpers.h>
2022-12-28 22:03:03 +00:00
#include <widgets/wx_infobar.h>
#include <wildcards_and_files_ext.h>
2021-02-22 23:47:17 +00:00
#include <drawing_sheet/ds_data_model.h>
#include <wx/app.h>
#include <wx/ffile.h>
2021-06-07 21:56:43 +00:00
#include <wx/filedlg.h>
#include <wx/log.h>
#include <wx/stdpaths.h>
#include <tools/ee_inspection_tool.h>
2021-01-23 04:17:32 +00:00
#include <paths.h>
#include <wx_filename.h> // For ::ResolvePossibleSymlinks
#include <widgets/wx_progress_reporters.h>
#include <widgets/wx_html_report_box.h>
#include <kiplatform/io.h>
#include "widgets/filedlg_hook_save_project.h"
bool SCH_EDIT_FRAME::OpenProjectFiles( const std::vector<wxString>& aFileSet, int aCtl )
{
// ensure the splash screen does not obscure any dialog at startup
Pgm().HideSplash();
// implement the pseudo code from KIWAY_PLAYER.h:
wxString msg;
EESCHEMA_SETTINGS* cfg = dynamic_cast<EESCHEMA_SETTINGS*>( Kiface().KifaceSettings() );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
// This is for python:
if( aFileSet.size() != 1 )
{
msg.Printf( "Eeschema:%s() takes only a single filename.", __WXFUNCTION__ );
DisplayError( this, msg );
return false;
}
wxString fullFileName( aFileSet[0] );
wxFileName wx_filename( fullFileName );
// We insist on caller sending us an absolute path, if it does not, we say it's a bug.
wxASSERT_MSG( wx_filename.IsAbsolute(), wxS( "Path is not absolute!" ) );
2014-09-07 19:01:26 +00:00
if( !LockFile( fullFileName ) )
{
msg.Printf( _( "Schematic '%s' is already open by '%s' at '%s'." ), fullFileName,
m_file_checker->GetUsername(), m_file_checker->GetHostname() );
if( !AskOverrideLock( this, msg ) )
return false;
m_file_checker->OverrideLock();
}
2017-09-20 14:20:38 +00:00
if( !AskToSaveChanges() )
return false;
#ifdef PROFILE
PROF_TIMER openFiles( "OpenProjectFile" );
#endif
wxFileName pro = fullFileName;
pro.SetExt( ProjectFileExtension );
2008-03-20 01:50:21 +00:00
bool is_new = !wxFileName::IsFileReadable( fullFileName );
2008-03-20 01:50:21 +00:00
// If its a non-existent schematic and caller thinks it exists
if( is_new && !( aCtl & KICTL_CREATE ) )
2008-03-20 01:50:21 +00:00
{
// notify user that fullFileName does not exist, ask if user wants to create it.
msg.Printf( _( "Schematic '%s' does not exist. Do you wish to create it?" ),
fullFileName );
if( !IsOK( this, msg ) )
return false;
2008-03-20 01:50:21 +00:00
}
// unload current project file before loading new
2008-03-20 01:50:21 +00:00
{
ClearUndoRedoList();
SetScreen( nullptr );
m_toolManager->GetTool<EE_INSPECTION_TOOL>()->Reset( TOOL_BASE::SUPERMODEL_RELOAD );
CreateScreens();
2008-03-20 01:50:21 +00:00
}
SetStatusText( wxEmptyString );
m_infoBar->Dismiss();
2008-03-20 01:50:21 +00:00
WX_PROGRESS_REPORTER progressReporter( this, is_new ? _( "Creating Schematic" )
: _( "Loading Schematic" ), 1 );
bool differentProject = pro.GetFullPath() != Prj().GetProjectFullName();
if( differentProject )
{
if( !Prj().IsNullProject() )
GetSettingsManager()->SaveProject();
Schematic().SetProject( nullptr );
GetSettingsManager()->UnloadProject( &Prj(), false );
GetSettingsManager()->LoadProject( pro.GetFullPath() );
wxFileName legacyPro( pro );
legacyPro.SetExt( LegacyProjectFileExtension );
// Do not allow saving a project if one doesn't exist. This normally happens if we are
// standalone and opening a schematic that has been moved from its project folder.
if( !pro.Exists() && !legacyPro.Exists() && !( aCtl & KICTL_CREATE ) )
Prj().SetReadOnly();
CreateScreens();
}
SCH_IO_MGR::SCH_FILE_T schFileType = SCH_IO_MGR::GuessPluginTypeFromSchPath( fullFileName );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
if( schFileType == SCH_IO_MGR::SCH_LEGACY )
{
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
// Don't reload the symbol libraries if we are just launching Eeschema from KiCad again.
// They are already saved in the kiface project object.
if( differentProject || !Prj().GetElem( PROJECT::ELEM_SCH_SYMBOL_LIBS ) )
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
{
// load the libraries here, not in SCH_SCREEN::Draw() which is a context
// that will not tolerate DisplayError() dialog since we're already in an
// event handler in there.
// And when a schematic file is loaded, we need these libs to initialize
// some parameters (links to PART LIB, dangling ends ...)
Prj().SetElem( PROJECT::ELEM_SCH_SYMBOL_LIBS, nullptr );
PROJECT_SCH::SchLibs( &Prj() );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
}
}
else
{
// No legacy symbol libraries including the cache are loaded with the new file format.
Prj().SetElem( PROJECT::ELEM_SCH_SYMBOL_LIBS, nullptr );
}
// Load the symbol library table, this will be used forever more.
Prj().SetElem( PROJECT::ELEM_SYMBOL_LIB_TABLE, nullptr );
PROJECT_SCH::SchSymbolLibTable( &Prj() );
// Load project settings after schematic has been set up with the project link, since this will
// update some of the needed schematic settings such as drawing defaults
LoadProjectSettings();
wxFileName rfn( GetCurrentFileName() );
rfn.MakeRelativeTo( Prj().GetProjectPath() );
LoadWindowState( rfn.GetFullPath() );
2020-09-01 10:14:51 +00:00
KIPLATFORM::APP::SetShutdownBlockReason( this, _( "Schematic file changes are unsaved" ) );
if( Kiface().IsSingle() )
{
KIPLATFORM::APP::RegisterApplicationRestart( fullFileName );
}
if( is_new || schFileType == SCH_IO_MGR::SCH_FILE_T::SCH_FILE_UNKNOWN )
2008-03-20 01:50:21 +00:00
{
// mark new, unsaved file as modified.
GetScreen()->SetContentModified();
GetScreen()->SetFileName( fullFileName );
if( schFileType == SCH_IO_MGR::SCH_FILE_T::SCH_FILE_UNKNOWN )
{
msg.Printf( _( "Unsupported schematic file '%s'." ), fullFileName );
progressReporter.Hide();
DisplayErrorMessage( this, msg );
}
2008-03-20 01:50:21 +00:00
}
else
{
wxFileName autoSaveFn = fullFileName;
autoSaveFn.SetName( getAutoSaveFileName() );
autoSaveFn.ClearExt();
if( ( aCtl & KICTL_REVERT ) )
{
DeleteAutoSaveFile( autoSaveFn );
}
else
{
// This will rename the file if there is an autosave and the user wants to recover
CheckForAutoSaveFile( autoSaveFn );
}
SetScreen( nullptr );
SCH_PLUGIN* plugin = SCH_IO_MGR::FindPlugin( schFileType );
SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( plugin );
pi->SetProgressReporter( &progressReporter );
bool failedLoad = false;
try
{
{
wxBusyCursor busy;
Schematic().SetRoot( pi->LoadSchematicFile( fullFileName, &Schematic() ) );
}
if( !pi->GetError().IsEmpty() )
{
DisplayErrorMessage( this, _( "The entire schematic could not be loaded. Errors "
"occurred attempting to load hierarchical sheets." ),
pi->GetError() );
}
}
catch( const FUTURE_FORMAT_ERROR& ffe )
{
msg.Printf( _( "Error loading schematic '%s'." ), fullFileName);
progressReporter.Hide();
DisplayErrorMessage( this, msg, ffe.Problem() );
failedLoad = true;
}
catch( const IO_ERROR& ioe )
{
msg.Printf( _( "Error loading schematic '%s'." ), fullFileName);
progressReporter.Hide();
DisplayErrorMessage( this, msg, ioe.What() );
failedLoad = true;
}
catch( const std::bad_alloc& )
{
msg.Printf( _( "Memory exhausted loading schematic '%s'." ), fullFileName );
progressReporter.Hide();
DisplayErrorMessage( this, msg, wxEmptyString );
failedLoad = true;
}
// This fixes a focus issue after the progress reporter is done on GTK. It shouldn't
// cause any issues on macOS and Windows. If it does, it will have to be conditionally
// compiled.
Raise();
if( failedLoad )
{
// Do not leave g_RootSheet == NULL because it is expected to be
// a valid sheet. Therefore create a dummy empty root sheet and screen.
CreateScreens();
m_toolManager->RunAction( ACTIONS::zoomFitScreen );
msg.Printf( _( "Failed to load '%s'." ), fullFileName );
SetMsgPanel( wxEmptyString, msg );
return false;
}
// It's possible the schematic parser fixed errors due to bugs so warn the user
// that the schematic has been fixed (modified).
SCH_SHEET_LIST sheetList = Schematic().GetSheets();
if( sheetList.IsModified() )
{
DisplayInfoMessage( this,
_( "An error was found when loading the schematic that has "
"been automatically fixed. Please save the schematic to "
"repair the broken file or it may not be usable with other "
"versions of KiCad." ) );
}
2008-03-20 01:50:21 +00:00
if( sheetList.AllSheetPageNumbersEmpty() )
sheetList.SetInitialPageNumbers();
UpdateFileHistory( fullFileName );
SCH_SCREENS schematic( Schematic().Root() );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
// LIB_ID checks and symbol rescue only apply to the legacy file formats.
if( schFileType == SCH_IO_MGR::SCH_LEGACY )
{
// Convert any legacy bus-bus entries to just be bus wires
for( SCH_SCREEN* screen = schematic.GetFirst(); screen; screen = schematic.GetNext() )
{
std::vector<SCH_ITEM*> deleted;
for( SCH_ITEM* item : screen->Items() )
{
if( item->Type() == SCH_BUS_BUS_ENTRY_T )
{
SCH_BUS_BUS_ENTRY* entry = static_cast<SCH_BUS_BUS_ENTRY*>( item );
std::unique_ptr<SCH_LINE> wire = std::make_unique<SCH_LINE>();
wire->SetLayer( LAYER_BUS );
wire->SetStartPoint( entry->GetPosition() );
wire->SetEndPoint( entry->GetEnd() );
screen->Append( wire.release() );
deleted.push_back( item );
}
}
for( SCH_ITEM* item : deleted )
screen->Remove( item );
}
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
// Convert old projects over to use symbol library table.
if( schematic.HasNoFullyDefinedLibIds() )
{
DIALOG_SYMBOL_REMAP dlgRemap( this );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
dlgRemap.ShowQuasiModal();
}
else
{
// Double check to ensure no legacy library list entries have been
// added to the project file symbol library list.
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
wxString paths;
wxArrayString libNames;
2022-10-11 10:22:09 +00:00
SYMBOL_LIBS::GetLibNamesAndPaths( &Prj(), &paths, &libNames );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
if( !libNames.IsEmpty() )
{
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
if( eeconfig()->m_Appearance.show_illegal_symbol_lib_dialog )
{
wxRichMessageDialog invalidLibDlg(
this,
_( "Illegal entry found in project file symbol library list." ),
_( "Project Load Warning" ),
wxOK | wxCENTER | wxICON_EXCLAMATION );
invalidLibDlg.ShowDetailedText(
_( "Symbol libraries defined in the project file symbol library "
"list are no longer supported and will be removed.\n\n"
"This may cause broken symbol library links under certain "
"conditions." ) );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
invalidLibDlg.ShowCheckBox( _( "Do not show this dialog again." ) );
invalidLibDlg.ShowModal();
eeconfig()->m_Appearance.show_illegal_symbol_lib_dialog =
!invalidLibDlg.IsCheckBoxChecked();
}
libNames.Clear();
paths.Clear();
2022-10-11 10:22:09 +00:00
SYMBOL_LIBS::SetLibNamesAndPaths( &Prj(), paths, libNames );
}
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
if( !cfg || !cfg->m_RescueNeverShow )
{
SCH_EDITOR_CONTROL* editor = m_toolManager->GetTool<SCH_EDITOR_CONTROL>();
editor->RescueSymbolLibTableProject( false );
}
}
// Ensure there is only one legacy library loaded and that it is the cache library.
SYMBOL_LIBS* legacyLibs = PROJECT_SCH::SchLibs( &Schematic().Prj() );
if( legacyLibs->GetLibraryCount() == 0 )
{
wxString extMsg;
wxFileName cacheFn = pro;
cacheFn.SetName( cacheFn.GetName() + "-cache" );
cacheFn.SetExt( LegacySymbolLibFileExtension );
msg.Printf( _( "The project symbol library cache file '%s' was not found." ),
cacheFn.GetFullName() );
extMsg = _( "This can result in a broken schematic under certain conditions. "
"If the schematic does not have any missing symbols upon opening, "
"save it immediately before making any changes to prevent data "
"loss. If there are missing symbols, either manual recovery of "
"the schematic or recovery of the symbol cache library file and "
"reloading the schematic is required." );
wxMessageDialog dlgMissingCache( this, msg, _( "Warning" ),
wxOK | wxCANCEL | wxICON_EXCLAMATION | wxCENTER );
dlgMissingCache.SetExtendedMessage( extMsg );
dlgMissingCache.SetOKCancelLabels(
wxMessageDialog::ButtonLabel( _( "Load Without Cache File" ) ),
wxMessageDialog::ButtonLabel( _( "Abort" ) ) );
if( dlgMissingCache.ShowModal() == wxID_CANCEL )
{
Schematic().Reset();
CreateScreens();
return false;
}
}
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
// Update all symbol library links for all sheets.
schematic.UpdateSymbolLinks();
m_infoBar->RemoveAllButtons();
m_infoBar->AddCloseButton();
m_infoBar->ShowMessage( _( "This file was created by an older version of KiCad. "
"It will be converted to the new format when saved." ),
2021-02-16 23:42:39 +00:00
wxICON_WARNING, WX_INFOBAR::MESSAGE_TYPE::OUTDATED_SAVE );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
// Legacy schematic can have duplicate time stamps so fix that before converting
// to the s-expression format.
schematic.ReplaceDuplicateTimeStamps();
for( SCH_SCREEN* screen = schematic.GetFirst(); screen; screen = schematic.GetNext() )
screen->FixLegacyPowerSymbolMismatches();
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
// Allow the schematic to be saved to new file format without making any edits.
OnModify();
}
else // S-expression schematic.
{
if( schematic.GetFirst()->GetFileFormatVersionAtLoad() < SEXPR_SCHEMATIC_FILE_VERSION )
{
m_infoBar->RemoveAllButtons();
m_infoBar->AddCloseButton();
m_infoBar->ShowMessage( _( "This file was created by an older version of KiCad. "
"It will be converted to the new format when saved." ),
2021-02-16 23:42:39 +00:00
wxICON_WARNING, WX_INFOBAR::MESSAGE_TYPE::OUTDATED_SAVE );
}
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
for( SCH_SCREEN* screen = schematic.GetFirst(); screen; screen = schematic.GetNext() )
screen->UpdateLocalLibSymbolLinks();
// Restore all of the loaded symbol and sheet instances from the root sheet.
if( Schematic().RootScreen()->GetFileFormatVersionAtLoad() < 20221002 )
sheetList.UpdateSymbolInstanceData( Schematic().RootScreen()->GetSymbolInstances());
if( Schematic().RootScreen()->GetFileFormatVersionAtLoad() < 20221110 )
sheetList.UpdateSheetInstanceData( Schematic().RootScreen()->GetSheetInstances());
if( Schematic().RootScreen()->GetFileFormatVersionAtLoad() < 20230221 )
for( SCH_SCREEN* screen = schematic.GetFirst(); screen; screen = schematic.GetNext() )
screen->FixLegacyPowerSymbolMismatches();
for( SCH_SCREEN* screen = schematic.GetFirst(); screen; screen = schematic.GetNext() )
screen->MigrateSimModels();
if( schematic.GetFirst()->GetFileFormatVersionAtLoad() < SEXPR_SCHEMATIC_FILE_VERSION )
{
// Allow the schematic to be saved to new file format without making any edits.
OnModify();
}
}
Schematic().ConnectionGraph()->Reset();
SetScreen( GetCurrentSheet().LastScreen() );
// Migrate conflicting bus definitions
// TODO(JE) This should only run once based on schematic file version
if( Schematic().ConnectionGraph()->GetBusesNeedingMigration().size() > 0 )
{
DIALOG_MIGRATE_BUSES dlg( this );
dlg.ShowQuasiModal();
OnModify();
}
SCH_COMMIT dummy( this );
RecalculateConnections( &dummy, GLOBAL_CLEANUP );
}
// Load any exclusions from the project file
Schematic().ResolveERCExclusionsPostUpdate();
Mark null project initial screen as zoom-initialized The variable `m_Initialized` in `BASE_SCREEN` is used by `SCH_EDIT_FRAME` to mark whether a screen had its zoom level initialized by the "zoom to fit screen" action. When this variable is `false`, the function `SCH_EDIT_FRAME::DisplayCurrentSheet()` performs "zoom to fit screen", modifying the zoom level. This function is indirectly called in the undo routines, so if `m_Initialized` is not set to `true`, a zoom change will occur when the user undoes an operation, a behavior that is undesired. `m_Initialized` was not initialized to `true` for the null schematic (the schematic that is loaded if no project is loaded), causing the aforementioned undesired behavior. To prevent this, I've changed the `SCH_EDIT_FRAME` constructor to set `m_Initialized` to `true`, since it zooms to fit screen already. I've moved `m_Initialized` from `BASE_SCREEN` to `SCH_SCREEN`, as it is used only in Eeschema, and renamed it to `m_zoomInitialized`, a name I believe that better describes what this variable does. I've also introduced the function `SCH_EDIT_FRAME::initScreenZoom()` to group the "zoom to fit screen" action with setting `m_Initialized` to `true`, as they often should occur together. I'd also like to say that I'm not confident whether `SCH_EDIT_FRAME::DisplayCurrentSheet()` should perform the zoom level initialization at this point, but I have decided to not change this behavior for now, as the commit history suggests it's several years old. Fixes https://gitlab.com/kicad/code/kicad/issues/7343
2021-01-30 22:47:39 +00:00
initScreenZoom();
SetSheetNumberAndCount();
RecomputeIntersheetRefs();
GetCurrentSheet().UpdateAllScreenReferences();
2022-08-18 21:19:28 +00:00
// Re-create junctions if needed. Eeschema optimizes wires by merging
// colinear segments. If a schematic is saved without a valid
// cache library or missing installed libraries, this can cause connectivity errors
// unless junctions are added.
2022-08-18 21:19:28 +00:00
//
// TODO: (RFB) This really needs to be put inside the Load() function of the SCH_LEGACY_PLUGIN
// I can't put it right now because of the extra code that is above to convert legacy bus-bus
// entries to bus wires
if( schFileType == SCH_IO_MGR::SCH_LEGACY )
2022-08-18 21:19:28 +00:00
Schematic().FixupJunctions();
SyncView();
GetScreen()->ClearDrawingState();
TestDanglingEnds();
UpdateHierarchyNavigator();
wxCommandEvent e( EDA_EVT_SCHEMATIC_CHANGED );
ProcessEventLocally( e );
for( wxEvtHandler* listener : m_schematicChangeListeners )
{
wxCHECK2( listener, continue );
// Use the windows variant when handling event messages in case there is any special
// event handler pre and/or post processing specific to windows.
wxWindow* win = dynamic_cast<wxWindow*>( listener );
if( win )
win->HandleWindowEvent( e );
else
listener->SafelyProcessEvent( e );
}
updateTitle();
m_toolManager->GetTool<SCH_NAVIGATE_TOOL>()->ResetHistory();
wxFileName fn = Prj().AbsolutePath( GetScreen()->GetFileName() );
if( fn.FileExists() && !fn.IsFileWritable() )
{
m_infoBar->RemoveAllButtons();
m_infoBar->AddCloseButton();
m_infoBar->ShowMessage( _( "Schematic is read only." ),
wxICON_WARNING, WX_INFOBAR::MESSAGE_TYPE::OUTDATED_SAVE );
}
#ifdef PROFILE
openFiles.Show();
#endif
return true;
}
Use legacy schematic plugin for loading schematics in all code paths. Use the legacy plugin schematic loader in the sheet edit and append schematic code paths. Check for fully qualified LIB_ID objects (must have library nickname) when loading existing schematics when edit sheets. Rewrite append schematic feature to handle import issues rather than change the name and file name of all of the sheets in the imported schematic. This includes the following: - Load the schematic into a temporary SCH_SHEET object. - Make sure the imported schematic does not cause any hierarchy recursion issues. - Verify the imported schematic uses fully qualified #LIB_ID objects (symbol library table). - Check to see if any symbol libraries need to be added to the current project's symbol library table. This includes: - Check if the symbol library already exists in the project or global symbol library table. - Convert symbol library URLS that use the ${KIPRJMOD} environment variable to absolute paths. ${KIPRJMOD} will not be the same for this project. - Check for duplicate symbol library nicknames and change the new symbol library nickname to prevent library name clashes. - Update all schematic symbol LIB_ID object library nicknames when the library nickname was changed to prevent clashes. - Check for duplicate sheet names which is illegal and automatically rename any duplicate sheets in the imported schematic. - Clear all of the annotation in the imported schematic to prevent clashes. - Append the objects from the temporary sheet to the current page. - Replace any duplicate time stamps. - Refresh the symbol library links. Add support code to SCH_SCREEN object to assist with schematic import. Doxygen comment cleaning. Fixes lp:1731760 https://bugs.launchpad.net/kicad/+bug/1731760
2017-11-17 17:00:04 +00:00
bool SCH_EDIT_FRAME::AppendSchematic()
{
SCH_SCREEN* screen = GetScreen();
if( !screen )
{
wxLogError( wxS( "Document not ready, cannot import" ) );
return false;
}
// open file chooser dialog
wxString path = wxPathOnly( Prj().GetProjectFullName() );
wxFileDialog dlg( this, _( "Insert Schematic" ), path, wxEmptyString,
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
KiCadSchematicFileWildcard(), wxFD_OPEN | wxFD_FILE_MUST_EXIST );
if( dlg.ShowModal() == wxID_CANCEL )
return false;
return AddSheetAndUpdateDisplay( dlg.GetPath() );
}
bool SCH_EDIT_FRAME::AddSheetAndUpdateDisplay( const wxString aFullFileName )
{
if( !LoadSheetFromFile( GetCurrentSheet().Last(), &GetCurrentSheet(), aFullFileName ) )
Use legacy schematic plugin for loading schematics in all code paths. Use the legacy plugin schematic loader in the sheet edit and append schematic code paths. Check for fully qualified LIB_ID objects (must have library nickname) when loading existing schematics when edit sheets. Rewrite append schematic feature to handle import issues rather than change the name and file name of all of the sheets in the imported schematic. This includes the following: - Load the schematic into a temporary SCH_SHEET object. - Make sure the imported schematic does not cause any hierarchy recursion issues. - Verify the imported schematic uses fully qualified #LIB_ID objects (symbol library table). - Check to see if any symbol libraries need to be added to the current project's symbol library table. This includes: - Check if the symbol library already exists in the project or global symbol library table. - Convert symbol library URLS that use the ${KIPRJMOD} environment variable to absolute paths. ${KIPRJMOD} will not be the same for this project. - Check for duplicate symbol library nicknames and change the new symbol library nickname to prevent library name clashes. - Update all schematic symbol LIB_ID object library nicknames when the library nickname was changed to prevent clashes. - Check for duplicate sheet names which is illegal and automatically rename any duplicate sheets in the imported schematic. - Clear all of the annotation in the imported schematic to prevent clashes. - Append the objects from the temporary sheet to the current page. - Replace any duplicate time stamps. - Refresh the symbol library links. Add support code to SCH_SCREEN object to assist with schematic import. Doxygen comment cleaning. Fixes lp:1731760 https://bugs.launchpad.net/kicad/+bug/1731760
2017-11-17 17:00:04 +00:00
return false;
Mark null project initial screen as zoom-initialized The variable `m_Initialized` in `BASE_SCREEN` is used by `SCH_EDIT_FRAME` to mark whether a screen had its zoom level initialized by the "zoom to fit screen" action. When this variable is `false`, the function `SCH_EDIT_FRAME::DisplayCurrentSheet()` performs "zoom to fit screen", modifying the zoom level. This function is indirectly called in the undo routines, so if `m_Initialized` is not set to `true`, a zoom change will occur when the user undoes an operation, a behavior that is undesired. `m_Initialized` was not initialized to `true` for the null schematic (the schematic that is loaded if no project is loaded), causing the aforementioned undesired behavior. To prevent this, I've changed the `SCH_EDIT_FRAME` constructor to set `m_Initialized` to `true`, since it zooms to fit screen already. I've moved `m_Initialized` from `BASE_SCREEN` to `SCH_SCREEN`, as it is used only in Eeschema, and renamed it to `m_zoomInitialized`, a name I believe that better describes what this variable does. I've also introduced the function `SCH_EDIT_FRAME::initScreenZoom()` to group the "zoom to fit screen" action with setting `m_Initialized` to `true`, as they often should occur together. I'd also like to say that I'm not confident whether `SCH_EDIT_FRAME::DisplayCurrentSheet()` should perform the zoom level initialization at this point, but I have decided to not change this behavior for now, as the commit history suggests it's several years old. Fixes https://gitlab.com/kicad/code/kicad/issues/7343
2021-01-30 22:47:39 +00:00
initScreenZoom();
SetSheetNumberAndCount();
SyncView();
OnModify();
HardRedraw(); // Full reinit of the current screen and the display.
UpdateHierarchyNavigator();
Use legacy schematic plugin for loading schematics in all code paths. Use the legacy plugin schematic loader in the sheet edit and append schematic code paths. Check for fully qualified LIB_ID objects (must have library nickname) when loading existing schematics when edit sheets. Rewrite append schematic feature to handle import issues rather than change the name and file name of all of the sheets in the imported schematic. This includes the following: - Load the schematic into a temporary SCH_SHEET object. - Make sure the imported schematic does not cause any hierarchy recursion issues. - Verify the imported schematic uses fully qualified #LIB_ID objects (symbol library table). - Check to see if any symbol libraries need to be added to the current project's symbol library table. This includes: - Check if the symbol library already exists in the project or global symbol library table. - Convert symbol library URLS that use the ${KIPRJMOD} environment variable to absolute paths. ${KIPRJMOD} will not be the same for this project. - Check for duplicate symbol library nicknames and change the new symbol library nickname to prevent library name clashes. - Update all schematic symbol LIB_ID object library nicknames when the library nickname was changed to prevent clashes. - Check for duplicate sheet names which is illegal and automatically rename any duplicate sheets in the imported schematic. - Clear all of the annotation in the imported schematic to prevent clashes. - Append the objects from the temporary sheet to the current page. - Replace any duplicate time stamps. - Refresh the symbol library links. Add support code to SCH_SCREEN object to assist with schematic import. Doxygen comment cleaning. Fixes lp:1731760 https://bugs.launchpad.net/kicad/+bug/1731760
2017-11-17 17:00:04 +00:00
return true;
}
void SCH_EDIT_FRAME::OnAppendProject( wxCommandEvent& event )
{
Use legacy schematic plugin for loading schematics in all code paths. Use the legacy plugin schematic loader in the sheet edit and append schematic code paths. Check for fully qualified LIB_ID objects (must have library nickname) when loading existing schematics when edit sheets. Rewrite append schematic feature to handle import issues rather than change the name and file name of all of the sheets in the imported schematic. This includes the following: - Load the schematic into a temporary SCH_SHEET object. - Make sure the imported schematic does not cause any hierarchy recursion issues. - Verify the imported schematic uses fully qualified #LIB_ID objects (symbol library table). - Check to see if any symbol libraries need to be added to the current project's symbol library table. This includes: - Check if the symbol library already exists in the project or global symbol library table. - Convert symbol library URLS that use the ${KIPRJMOD} environment variable to absolute paths. ${KIPRJMOD} will not be the same for this project. - Check for duplicate symbol library nicknames and change the new symbol library nickname to prevent library name clashes. - Update all schematic symbol LIB_ID object library nicknames when the library nickname was changed to prevent clashes. - Check for duplicate sheet names which is illegal and automatically rename any duplicate sheets in the imported schematic. - Clear all of the annotation in the imported schematic to prevent clashes. - Append the objects from the temporary sheet to the current page. - Replace any duplicate time stamps. - Refresh the symbol library links. Add support code to SCH_SCREEN object to assist with schematic import. Doxygen comment cleaning. Fixes lp:1731760 https://bugs.launchpad.net/kicad/+bug/1731760
2017-11-17 17:00:04 +00:00
if( GetScreen() && GetScreen()->IsModified() )
{
wxString msg = _( "This operation cannot be undone.\n\n"
"Do you want to save the current document before proceeding?" );
Use legacy schematic plugin for loading schematics in all code paths. Use the legacy plugin schematic loader in the sheet edit and append schematic code paths. Check for fully qualified LIB_ID objects (must have library nickname) when loading existing schematics when edit sheets. Rewrite append schematic feature to handle import issues rather than change the name and file name of all of the sheets in the imported schematic. This includes the following: - Load the schematic into a temporary SCH_SHEET object. - Make sure the imported schematic does not cause any hierarchy recursion issues. - Verify the imported schematic uses fully qualified #LIB_ID objects (symbol library table). - Check to see if any symbol libraries need to be added to the current project's symbol library table. This includes: - Check if the symbol library already exists in the project or global symbol library table. - Convert symbol library URLS that use the ${KIPRJMOD} environment variable to absolute paths. ${KIPRJMOD} will not be the same for this project. - Check for duplicate symbol library nicknames and change the new symbol library nickname to prevent library name clashes. - Update all schematic symbol LIB_ID object library nicknames when the library nickname was changed to prevent clashes. - Check for duplicate sheet names which is illegal and automatically rename any duplicate sheets in the imported schematic. - Clear all of the annotation in the imported schematic to prevent clashes. - Append the objects from the temporary sheet to the current page. - Replace any duplicate time stamps. - Refresh the symbol library links. Add support code to SCH_SCREEN object to assist with schematic import. Doxygen comment cleaning. Fixes lp:1731760 https://bugs.launchpad.net/kicad/+bug/1731760
2017-11-17 17:00:04 +00:00
if( IsOK( this, msg ) )
SaveProject();
Use legacy schematic plugin for loading schematics in all code paths. Use the legacy plugin schematic loader in the sheet edit and append schematic code paths. Check for fully qualified LIB_ID objects (must have library nickname) when loading existing schematics when edit sheets. Rewrite append schematic feature to handle import issues rather than change the name and file name of all of the sheets in the imported schematic. This includes the following: - Load the schematic into a temporary SCH_SHEET object. - Make sure the imported schematic does not cause any hierarchy recursion issues. - Verify the imported schematic uses fully qualified #LIB_ID objects (symbol library table). - Check to see if any symbol libraries need to be added to the current project's symbol library table. This includes: - Check if the symbol library already exists in the project or global symbol library table. - Convert symbol library URLS that use the ${KIPRJMOD} environment variable to absolute paths. ${KIPRJMOD} will not be the same for this project. - Check for duplicate symbol library nicknames and change the new symbol library nickname to prevent library name clashes. - Update all schematic symbol LIB_ID object library nicknames when the library nickname was changed to prevent clashes. - Check for duplicate sheet names which is illegal and automatically rename any duplicate sheets in the imported schematic. - Clear all of the annotation in the imported schematic to prevent clashes. - Append the objects from the temporary sheet to the current page. - Replace any duplicate time stamps. - Refresh the symbol library links. Add support code to SCH_SCREEN object to assist with schematic import. Doxygen comment cleaning. Fixes lp:1731760 https://bugs.launchpad.net/kicad/+bug/1731760
2017-11-17 17:00:04 +00:00
}
Use legacy schematic plugin for loading schematics in all code paths. Use the legacy plugin schematic loader in the sheet edit and append schematic code paths. Check for fully qualified LIB_ID objects (must have library nickname) when loading existing schematics when edit sheets. Rewrite append schematic feature to handle import issues rather than change the name and file name of all of the sheets in the imported schematic. This includes the following: - Load the schematic into a temporary SCH_SHEET object. - Make sure the imported schematic does not cause any hierarchy recursion issues. - Verify the imported schematic uses fully qualified #LIB_ID objects (symbol library table). - Check to see if any symbol libraries need to be added to the current project's symbol library table. This includes: - Check if the symbol library already exists in the project or global symbol library table. - Convert symbol library URLS that use the ${KIPRJMOD} environment variable to absolute paths. ${KIPRJMOD} will not be the same for this project. - Check for duplicate symbol library nicknames and change the new symbol library nickname to prevent library name clashes. - Update all schematic symbol LIB_ID object library nicknames when the library nickname was changed to prevent clashes. - Check for duplicate sheet names which is illegal and automatically rename any duplicate sheets in the imported schematic. - Clear all of the annotation in the imported schematic to prevent clashes. - Append the objects from the temporary sheet to the current page. - Replace any duplicate time stamps. - Refresh the symbol library links. Add support code to SCH_SCREEN object to assist with schematic import. Doxygen comment cleaning. Fixes lp:1731760 https://bugs.launchpad.net/kicad/+bug/1731760
2017-11-17 17:00:04 +00:00
AppendSchematic();
}
2017-09-20 14:20:38 +00:00
void SCH_EDIT_FRAME::OnImportProject( wxCommandEvent& aEvent )
{
if( Schematic().RootScreen() && !Schematic().RootScreen()->Items().empty() )
{
wxString msg = _( "This operation replaces the contents of the current schematic, "
"which will be permanently lost.\n\n"
"Do you want to proceed?" );
if( !IsOK( this, msg ) )
return;
}
// Set the project location if none is set or if we are running in standalone mode
bool setProject = Prj().GetProjectFullName().IsEmpty() || Kiface().IsSingle();
2017-09-20 14:20:38 +00:00
wxString path = wxPathOnly( Prj().GetProjectFullName() );
wxString fileFiltersStr;
wxString allWildcardsStr;
for( const SCH_IO_MGR::SCH_FILE_T& fileType : SCH_IO_MGR::SCH_FILE_T_vector )
{
if( fileType == SCH_IO_MGR::SCH_KICAD || fileType == SCH_IO_MGR::SCH_LEGACY )
continue; // this is "Import non-KiCad schematic"
SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( fileType ) );
if( !pi )
continue;
const PLUGIN_FILE_DESC& desc = pi->GetSchematicFileDesc();
if( desc.m_FileExtensions.empty() )
continue;
if( !fileFiltersStr.IsEmpty() )
fileFiltersStr += wxChar( '|' );
fileFiltersStr += desc.FileFilter();
for( const std::string& ext : desc.m_FileExtensions )
allWildcardsStr << wxS( "*." ) << formatWildcardExt( ext ) << wxS( ";" );
}
fileFiltersStr = _( "All supported formats" ) + wxS( "|" ) + allWildcardsStr + wxS( "|" )
+ fileFiltersStr;
wxFileDialog dlg( this, _( "Import Schematic" ), path, wxEmptyString, fileFiltersStr,
wxFD_OPEN | wxFD_FILE_MUST_EXIST ); // TODO
2017-09-20 14:20:38 +00:00
if( dlg.ShowModal() == wxID_CANCEL )
return;
// Don't leave dangling pointers to previously-opened document.
m_toolManager->GetTool<EE_SELECTION_TOOL>()->ClearSelection();
ClearUndoRedoList();
if( setProject )
{
Schematic().SetProject( nullptr );
GetSettingsManager()->UnloadProject( &Prj(), false );
// Clear view before destroying schematic as repaints depend on schematic being valid
SetScreen( nullptr );
Schematic().Reset();
wxFileName projectFn( dlg.GetPath() );
projectFn.SetExt( ProjectFileExtension );
GetSettingsManager()->LoadProject( projectFn.GetFullPath() );
Schematic().SetProject( &Prj() );
}
wxFileName fn = dlg.GetPath();
SCH_IO_MGR::SCH_FILE_T pluginType = SCH_IO_MGR::SCH_FILE_T::SCH_FILE_UNKNOWN;
for( const SCH_IO_MGR::SCH_FILE_T& fileType : SCH_IO_MGR::SCH_FILE_T_vector )
{
SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( fileType ) );
if( !pi )
continue;
if( pi->CanReadSchematicFile( fn.GetFullPath() ) )
{
pluginType = fileType;
break;
}
}
if( pluginType == SCH_IO_MGR::SCH_FILE_T::SCH_FILE_UNKNOWN )
{
wxLogError( _( "No loader can read the specified file: '%s'." ), fn.GetFullPath() );
return;
}
importFile( dlg.GetPath(), pluginType );
RefreshCanvas();
2017-09-20 14:20:38 +00:00
}
bool SCH_EDIT_FRAME::saveSchematicFile( SCH_SHEET* aSheet, const wxString& aSavePath )
{
wxString msg;
wxFileName schematicFileName;
wxFileName oldFileName;
bool success;
SCH_SCREEN* screen = aSheet->GetScreen();
wxCHECK( screen, false );
// Cannot save to nowhere
wxCHECK( !aSavePath.IsEmpty(), false );
// Construct the name of the file to be saved
schematicFileName = Prj().AbsolutePath( aSavePath );
oldFileName = schematicFileName;
// Write through symlinks, don't replace them
WX_FILENAME::ResolvePossibleSymlinks( schematicFileName );
if( !IsWritable( schematicFileName ) )
return false;
wxFileName projectFile( schematicFileName );
projectFile.SetExt( ProjectFileExtension );
if( projectFile.FileExists() )
{
// Save various ERC settings, such as violation severities (which may have been edited
// via the ERC dialog as well as the Schematic Setup dialog), ERC exclusions, etc.
saveProjectSettings();
}
2023-01-22 14:41:33 +00:00
wxString tempFile = wxFileName::CreateTempFileName( wxS( "eeschema" ) );
// Save
2023-01-22 14:41:33 +00:00
wxLogTrace( traceAutoSave, wxS( "Saving file " ) + schematicFileName.GetFullPath() );
if( m_infoBar->GetMessageType() == WX_INFOBAR::MESSAGE_TYPE::OUTDATED_SAVE )
m_infoBar->Dismiss();
SCH_IO_MGR::SCH_FILE_T pluginType = SCH_IO_MGR::GuessPluginTypeFromSchPath(
schematicFileName.GetFullPath() );
if( pluginType == SCH_IO_MGR::SCH_FILE_UNKNOWN )
pluginType = SCH_IO_MGR::SCH_KICAD;
SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( pluginType ) );
try
{
pi->SaveSchematicFile( tempFile, aSheet, &Schematic() );
success = true;
}
catch( const IO_ERROR& ioe )
{
msg.Printf( _( "Error saving schematic file '%s'.\n%s" ),
schematicFileName.GetFullPath(),
ioe.What() );
DisplayError( this, msg );
msg.Printf( _( "Failed to create temporary file '%s'." ),
tempFile );
SetMsgPanel( wxEmptyString, msg );
// In case we started a file but didn't fully write it, clean up
wxRemoveFile( tempFile );
success = false;
}
if( success )
{
// Preserve the permissions of the current file
KIPLATFORM::IO::DuplicatePermissions( schematicFileName.GetFullPath(), tempFile );
// Replace the original with the temporary file we just wrote
success = wxRenameFile( tempFile, schematicFileName.GetFullPath() );
if( !success )
{
msg.Printf( _( "Error saving schematic file '%s'.\n"
"Failed to rename temporary file '%s'." ),
schematicFileName.GetFullPath(),
tempFile );
DisplayError( this, msg );
msg.Printf( _( "Failed to rename temporary file '%s'." ),
tempFile );
SetMsgPanel( wxEmptyString, msg );
}
}
if( success )
{
// Delete auto save file.
wxFileName autoSaveFileName = schematicFileName;
autoSaveFileName.SetName( GetAutoSaveFilePrefix() + schematicFileName.GetName() );
if( autoSaveFileName.FileExists() )
{
wxLogTrace( traceAutoSave,
wxS( "Removing auto save file <" ) + autoSaveFileName.GetFullPath() +
wxS( ">" ) );
wxRemoveFile( autoSaveFileName.GetFullPath() );
}
screen->SetContentModified( false );
msg.Printf( _( "File '%s' saved." ), screen->GetFileName() );
SetStatusText( msg, 0 );
}
else
{
DisplayError( this, _( "File write operation failed." ) );
}
return success;
}
bool SCH_EDIT_FRAME::SaveProject( bool aSaveAs )
{
wxString msg;
SCH_SCREEN* screen;
SCH_SCREENS screens( Schematic().Root() );
bool saveCopy = aSaveAs && !Kiface().IsSingle();
bool success = true;
bool updateFileHistory = false;
bool createNewProject = false;
// I want to see it in the debugger, show me the string! Can't do that with wxFileName.
wxString fileName = Prj().AbsolutePath( Schematic().Root().GetFileName() );
wxFileName fn = fileName;
// Path to save each screen to: will be the stored filename by default, but is overwritten by
// a Save As Copy operation.
std::unordered_map<SCH_SCREEN*, wxString> filenameMap;
// Handle "Save As" and saving a new project/schematic for the first time in standalone
if( Prj().IsNullProject() || aSaveAs )
{
// Null project should only be possible in standalone mode.
wxCHECK( Kiface().IsSingle() || aSaveAs, false );
wxFileName newFileName;
wxFileName savePath( Prj().GetProjectFullName() );
if( !savePath.IsOk() || !savePath.IsDirWritable() )
{
savePath = GetMruPath();
if( !savePath.IsOk() || !savePath.IsDirWritable() )
savePath = PATHS::GetDefaultUserProjectsPath();
}
if( savePath.HasExt() )
savePath.SetExt( KiCadSchematicFileExtension );
else
savePath.SetName( wxEmptyString );
wxFileDialog dlg( this, _( "Schematic Files" ), savePath.GetPath(),
savePath.GetFullName(), KiCadSchematicFileWildcard(),
wxFD_SAVE | wxFD_OVERWRITE_PROMPT );
FILEDLG_HOOK_SAVE_PROJECT newProjectHook;
// Add a "Create a project" checkbox in standalone mode and one isn't loaded
if( Kiface().IsSingle() || aSaveAs )
{
dlg.SetCustomizeHook( newProjectHook );
}
if( dlg.ShowModal() == wxID_CANCEL )
return false;
newFileName = EnsureFileExtension( dlg.GetPath(), KiCadSchematicFileExtension );
if( ( !newFileName.DirExists() && !newFileName.Mkdir() ) ||
!newFileName.IsDirWritable() )
{
msg.Printf( _( "Folder '%s' could not be created.\n\n"
"Make sure you have write permissions and try again." ),
newFileName.GetPath() );
wxMessageDialog dlgBadPath( this, msg, _( "Error" ),
wxOK | wxICON_EXCLAMATION | wxCENTER );
dlgBadPath.ShowModal();
return false;
}
if( newProjectHook.IsAttachedToDialog() )
createNewProject = newProjectHook.GetCreateNewProject();
if( !saveCopy )
{
Schematic().Root().SetFileName( newFileName.GetFullName() );
Schematic().RootScreen()->SetFileName( newFileName.GetFullPath() );
updateFileHistory = true;
}
else
{
filenameMap[Schematic().RootScreen()] = newFileName.GetFullPath();
}
// Set the base path to all new sheets.
for( size_t i = 0; i < screens.GetCount(); i++ )
{
screen = screens.GetScreen( i );
wxCHECK2( screen, continue );
// The root screen file name has already been set.
if( screen == Schematic().RootScreen() )
continue;
wxFileName tmp = screen->GetFileName();
// Assume existing sheet files are being reused and do not save them to the new
// path. Maybe in the future, add a user option to copy schematic files to the
// new project path.
if( tmp.FileExists() )
continue;
if( tmp.GetPath().IsEmpty() )
{
tmp.SetPath( newFileName.GetPath() );
}
else if( tmp.GetPath() == fn.GetPath() )
{
tmp.SetPath( newFileName.GetPath() );
}
else if( tmp.GetPath().StartsWith( fn.GetPath() ) )
{
// NOTE: this hasn't been tested because the sheet properties dialog no longer
// allows adding a path specifier in the file name field.
wxString newPath = newFileName.GetPath();
newPath += tmp.GetPath().Right( fn.GetPath().Length() );
tmp.SetPath( newPath );
}
wxLogTrace( tracePathsAndFiles,
wxS( "Moving schematic from '%s' to '%s'." ),
screen->GetFileName(),
tmp.GetFullPath() );
if( !tmp.DirExists() && !tmp.Mkdir() )
{
msg.Printf( _( "Folder '%s' could not be created.\n\n"
"Make sure you have write permissions and try again." ),
newFileName.GetPath() );
wxMessageDialog dlgBadFilePath( this, msg, _( "Error" ),
wxOK | wxICON_EXCLAMATION | wxCENTER );
dlgBadFilePath.ShowModal();
return false;
}
if( saveCopy )
filenameMap[screen] = tmp.GetFullPath();
else
screen->SetFileName( tmp.GetFullPath() );
}
// Attempt to make sheet file name paths relative to the new root schematic path.
SCH_SHEET_LIST sheets = Schematic().GetSheets();
for( SCH_SHEET_PATH& sheet : sheets )
{
if( sheet.Last()->IsRootSheet() )
continue;
sheet.MakeFilePathRelativeToParentSheet();
}
}
else if( !fn.FileExists() )
{
// File doesn't exist yet; true if we just imported something
updateFileHistory = true;
}
else if( !Schematic().GetSheets().IsModified() )
{
return true;
}
if( filenameMap.empty() || !saveCopy )
{
for( size_t i = 0; i < screens.GetCount(); i++ )
filenameMap[screens.GetScreen( i )] = screens.GetScreen( i )->GetFileName();
}
// Warn user on potential file overwrite. This can happen on shared sheets.
wxArrayString overwrittenFiles;
wxArrayString lockedFiles;
for( size_t i = 0; i < screens.GetCount(); i++ )
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
{
screen = screens.GetScreen( i );
wxCHECK2( screen, continue );
// Convert legacy schematics file name extensions for the new format.
wxFileName tmpFn = filenameMap[screen];
if( !tmpFn.IsOk() )
continue;
if( tmpFn.FileExists() && !tmpFn.IsFileWritable() )
lockedFiles.Add( tmpFn.GetFullPath() );
if( tmpFn.GetExt() == KiCadSchematicFileExtension )
continue;
tmpFn.SetExt( KiCadSchematicFileExtension );
if( tmpFn.FileExists() )
overwrittenFiles.Add( tmpFn.GetFullPath() );
}
if( !lockedFiles.IsEmpty() )
{
for( const wxString& lockedFile : lockedFiles )
{
if( msg.IsEmpty() )
msg = lockedFile;
else
msg += "\n" + lockedFile;
}
wxRichMessageDialog dlg( this, wxString::Format( _( "Failed to save %s." ),
Schematic().Root().GetFileName() ),
_( "Locked File Warning" ),
wxOK | wxICON_WARNING | wxCENTER );
dlg.SetExtendedMessage( _( "You do not have write permissions to:\n\n" ) + msg );
dlg.ShowModal();
return false;
}
if( !overwrittenFiles.IsEmpty() )
{
for( const wxString& overwrittenFile : overwrittenFiles )
{
if( msg.IsEmpty() )
msg = overwrittenFile;
else
msg += "\n" + overwrittenFile;
}
wxRichMessageDialog dlg( this, _( "Saving will overwrite existing files." ),
_( "Save Warning" ),
wxOK | wxCANCEL | wxCANCEL_DEFAULT | wxCENTER |
wxICON_EXCLAMATION );
dlg.ShowDetailedText( _( "The following files will be overwritten:\n\n" ) + msg );
dlg.SetOKCancelLabels( wxMessageDialog::ButtonLabel( _( "Overwrite Files" ) ),
wxMessageDialog::ButtonLabel( _( "Abort Project Save" ) ) );
if( dlg.ShowModal() == wxID_CANCEL )
return false;
}
screens.BuildClientSheetPathList();
for( size_t i = 0; i < screens.GetCount(); i++ )
{
screen = screens.GetScreen( i );
wxCHECK2( screen, continue );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
// Convert legacy schematics file name extensions for the new format.
wxFileName tmpFn = filenameMap[screen];
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
if( tmpFn.IsOk() && tmpFn.GetExt() != KiCadSchematicFileExtension )
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
{
updateFileHistory = true;
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
tmpFn.SetExt( KiCadSchematicFileExtension );
2022-07-29 21:02:35 +00:00
for( EDA_ITEM* item : screen->Items().OfType( SCH_SHEET_T ) )
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
{
SCH_SHEET* sheet = static_cast<SCH_SHEET*>( item );
wxFileName sheetFileName = sheet->GetFileName();
if( !sheetFileName.IsOk() || sheetFileName.GetExt() == KiCadSchematicFileExtension )
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
continue;
sheetFileName.SetExt( KiCadSchematicFileExtension );
sheet->SetFileName( sheetFileName.GetFullPath() );
UpdateItem( sheet );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
}
filenameMap[screen] = tmpFn.GetFullPath();
if( !saveCopy )
screen->SetFileName( tmpFn.GetFullPath() );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
}
// Do not save sheet symbols with no valid filename set
if( !tmpFn.IsOk() )
continue;
std::vector<SCH_SHEET_PATH>& sheets = screen->GetClientSheetPaths();
if( sheets.size() == 1 )
screen->SetVirtualPageNumber( 1 );
else
screen->SetVirtualPageNumber( 0 ); // multiple uses; no way to store the real sheet #
// This is a new schematic file so make sure it has a unique ID.
if( !saveCopy && tmpFn.GetFullPath() != screen->GetFileName() )
screen->AssignNewUuid();
success &= saveSchematicFile( screens.GetSheet( i ), tmpFn.GetFullPath() );
Make the new schematic and symbol library file formats the default. This is a very large and potentially disruptive change so this will be an unusually long and detailed commit message. The new file formats are now the default in both the schematic and symbol library editors. Existing symbol libraries will be saved in their current format until new features are added to library symbols. Once this happens, both the legacy schematic and symbol file formats will be no longer be savable and existing libraries will have to be converted. Saving to the legacy file formats is still available for round robin testing and should not be used for normal editing. When loading the legacy schematic file, it is imperative that the schematic library symbols are rescued and/or remapped to valid library identifiers. Otherwise, there will be no way to link to the original library symbol and the user will be required manually set the library identifier. The cached symbol will be saved in the schematic file so the last library symbol in the cache will still be used but there will be no way to update it from the original library. The next save after loading a legacy schematic file will be converted to the s-expression file format. Schematics with hierarchical sheets will automatically have all sheet file name extensions changed to .kicad_sym and saved to the new format as well. Appending schematics requires that the schematic to append has already been converted to the new file format. This is required to ensure that library symbols are guaranteed to be valid for the appended schematic. The schematic symbol library symbol link resolution has been moved out of the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the symbol. This was done to ensure that there is a single place where the library symbol links get resolved rather than the dozen or so different code paths that previously existed. It also removes the necessity of the SCH_COMPONENT object of requiring any knowledge of the symbol library table and/or the cache library. When opening an s-expression schematic, the legacy cache library is not loaded so any library symbols not rescued cannot be loaded. Broken library symbol links will have to be manually resolved by adding the cache library to the symbol library table and changing the links in the schematic symbol. Now that the library symbols are embedded in the schematic file, the SCH_SCREEN object maintains the list of library symbols for the schematic automatically. No external manipulation of this library cache should ever occur. ADDED: S-expression schematic and symbol library file formats.
2020-04-16 16:43:50 +00:00
}
if( success )
m_autoSaveRequired = false;
// One or more of the modified sheets did not save correctly so update the auto save file.
if( !aSaveAs && !success )
success &= updateAutoSaveFile();
if( aSaveAs && success )
LockFile( Schematic().RootScreen()->GetFileName() );
if( updateFileHistory )
UpdateFileHistory( Schematic().RootScreen()->GetFileName() );
// Save the sheet name map to the project file
2020-05-26 02:27:27 +00:00
std::vector<FILE_INFO_PAIR>& sheets = Prj().GetProjectFile().GetSheets();
sheets.clear();
for( SCH_SHEET_PATH& sheetPath : Schematic().GetSheets() )
{
SCH_SHEET* sheet = sheetPath.Last();
wxCHECK2( sheet, continue );
// Use the schematic UUID for the root sheet.
if( sheet->IsRootSheet() )
{
screen = sheet->GetScreen();
wxCHECK2( screen, continue );
sheets.emplace_back( std::make_pair( screen->GetUuid(), sheet->GetName() ) );
}
else
{
sheets.emplace_back( std::make_pair( sheet->m_Uuid, sheet->GetName() ) );
}
}
wxASSERT( filenameMap.count( Schematic().RootScreen() ) );
wxFileName projectPath( filenameMap.at( Schematic().RootScreen() ) );
projectPath.SetExt( ProjectFileExtension );
if( Prj().IsNullProject() || ( aSaveAs && !saveCopy ) )
{
Prj().SetReadOnly( !createNewProject );
GetSettingsManager()->SaveProjectAs( projectPath.GetFullPath() );
}
else if( saveCopy && createNewProject )
{
GetSettingsManager()->SaveProjectCopy( projectPath.GetFullPath() );
}
else
{
saveProjectSettings();
}
if( !Kiface().IsSingle() )
{
WX_STRING_REPORTER backupReporter( &msg );
if( !GetSettingsManager()->TriggerBackupIfNeeded( backupReporter ) )
SetStatusText( msg, 0 );
}
updateTitle();
if( m_infoBar->GetMessageType() == WX_INFOBAR::MESSAGE_TYPE::OUTDATED_SAVE )
m_infoBar->Dismiss();
2021-02-16 23:42:39 +00:00
return success;
}
bool SCH_EDIT_FRAME::doAutoSave()
{
wxFileName tmpFileName = Schematic().Root().GetFileName();
wxFileName fn = tmpFileName;
wxFileName tmp;
SCH_SCREENS screens( Schematic().Root() );
// Don't run autosave if content has not been modified
if( !IsContentModified() )
return true;
bool autoSaveOk = true;
if( fn.GetPath().IsEmpty() )
tmp.AssignDir( Prj().GetProjectPath() );
else
tmp.AssignDir( fn.GetPath() );
if( !tmp.IsOk() )
return false;
if( !IsWritable( tmp ) )
return false;
wxString title = GetTitle(); // Save frame title, that can be modified by the save process
for( size_t i = 0; i < screens.GetCount(); i++ )
{
// Only create auto save files for the schematics that have been modified.
if( !screens.GetScreen( i )->IsContentModified() )
continue;
tmpFileName = fn = screens.GetScreen( i )->GetFileName();
// Auto save file name is the normal file name prefixed with GetAutoSavePrefix().
fn.SetName( GetAutoSaveFilePrefix() + fn.GetName() );
if( saveSchematicFile( screens.GetSheet( i ), fn.GetFullPath() ) )
2022-10-10 11:04:19 +00:00
{
// This was only an auto-save, not a real save. Reset the modified flag.
screens.GetScreen( i )->SetContentModified();
2022-10-10 11:04:19 +00:00
}
else
2022-10-10 11:04:19 +00:00
{
autoSaveOk = false;
2022-10-10 11:04:19 +00:00
}
}
if( autoSaveOk && updateAutoSaveFile() )
{
m_autoSaveRequired = false;
2022-10-10 11:04:19 +00:00
m_autoSavePending = false;
if( !Kiface().IsSingle()
&& GetSettingsManager()->GetCommonSettings()->m_Backup.backup_on_autosave )
{
GetSettingsManager()->TriggerBackupIfNeeded( NULL_REPORTER::GetInstance() );
}
}
SetTitle( title );
return autoSaveOk;
}
bool SCH_EDIT_FRAME::importFile( const wxString& aFileName, int aFileType,
const STRING_UTF8_MAP* aProperties )
{
wxFileName filename( aFileName );
wxFileName newfilename;
SCH_SHEET_LIST sheetList = Schematic().GetSheets();
SCH_IO_MGR::SCH_FILE_T fileType = (SCH_IO_MGR::SCH_FILE_T) aFileType;
switch( fileType )
{
case SCH_IO_MGR::SCH_ALTIUM:
case SCH_IO_MGR::SCH_CADSTAR_ARCHIVE:
case SCH_IO_MGR::SCH_EAGLE:
case SCH_IO_MGR::SCH_LTSPICE:
case SCH_IO_MGR::SCH_EASYEDA:
case SCH_IO_MGR::SCH_EASYEDAPRO:
{
// We insist on caller sending us an absolute path, if it does not, we say it's a bug.
wxCHECK_MSG( filename.IsAbsolute(), false,
wxS( "Import schematic: path is not absolute!" ) );
try
{
SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( fileType ) );
DIALOG_HTML_REPORTER errorReporter( this );
WX_PROGRESS_REPORTER progressReporter( this, _( "Importing Schematic" ), 1 );
PROJECT_CHOOSER_PLUGIN* projectChooserPlugin =
dynamic_cast<PROJECT_CHOOSER_PLUGIN*>( (SCH_PLUGIN*) pi );
if( projectChooserPlugin )
{
projectChooserPlugin->RegisterChooseProjectCallback(
std::bind( DIALOG_IMPORT_CHOOSE_PROJECT::GetSelectionsModal, this,
std::placeholders::_1 ) );
}
pi->SetReporter( errorReporter.m_Reporter );
pi->SetProgressReporter( &progressReporter );
SCH_SHEET* loadedSheet =
pi->LoadSchematicFile( aFileName, &Schematic(), nullptr, aProperties );
if( loadedSheet )
{
Schematic().SetRoot( loadedSheet );
if( errorReporter.m_Reporter->HasMessage() )
{
errorReporter.m_Reporter->Flush(); // Build HTML messages
errorReporter.ShowModal();
}
// Non-KiCad schematics do not use a drawing-sheet (or if they do, it works differently
// to KiCad), so set it to an empty one
DS_DATA_MODEL& drawingSheet = DS_DATA_MODEL::GetTheInstance();
drawingSheet.SetEmptyLayout();
BASE_SCREEN::m_DrawingSheetFileName = "empty.kicad_wks";
newfilename.SetPath( Prj().GetProjectPath() );
newfilename.SetName( Prj().GetProjectName() );
newfilename.SetExt( KiCadSchematicFileExtension );
SetScreen( GetCurrentSheet().LastScreen() );
Schematic().Root().SetFileName( newfilename.GetFullName() );
GetScreen()->SetFileName( newfilename.GetFullPath() );
GetScreen()->SetContentModified();
RecalculateConnections( nullptr, GLOBAL_CLEANUP );
// Only perform the dangling end test on root sheet.
GetScreen()->TestDanglingEnds();
}
else
{
CreateScreens();
}
}
catch( const IO_ERROR& ioe )
{
// Do not leave g_RootSheet == NULL because it is expected to be
// a valid sheet. Therefore create a dummy empty root sheet and screen.
CreateScreens();
m_toolManager->RunAction( ACTIONS::zoomFitScreen );
wxString msg = wxString::Format( _( "Error loading schematic '%s'." ), aFileName );
DisplayErrorMessage( this, msg, ioe.What() );
msg.Printf( _( "Failed to load '%s'." ), aFileName );
SetMsgPanel( wxEmptyString, msg );
}
catch( const std::exception& exc )
{
CreateScreens();
m_toolManager->RunAction( ACTIONS::zoomFitScreen );
wxString msg = wxString::Format( _( "Unhandled exception occurred loading schematic "
"'%s'." ), aFileName );
DisplayErrorMessage( this, msg, exc.what() );
msg.Printf( _( "Failed to load '%s'." ), aFileName );
SetMsgPanel( wxEmptyString, msg );
}
ClearUndoRedoList();
initScreenZoom();
SetSheetNumberAndCount();
SyncView();
UpdateHierarchyNavigator();
wxCommandEvent e( EDA_EVT_SCHEMATIC_CHANGED );
ProcessEventLocally( e );
for( wxEvtHandler* listener : m_schematicChangeListeners )
{
wxCHECK2( listener, continue );
// Use the windows variant when handling event messages in case there is any
// special event handler pre and/or post processing specific to windows.
wxWindow* win = dynamic_cast<wxWindow*>( listener );
if( win )
win->HandleWindowEvent( e );
else
listener->SafelyProcessEvent( e );
}
updateTitle();
break;
}
default:
break;
}
return true;
}
2017-09-20 14:20:38 +00:00
bool SCH_EDIT_FRAME::AskToSaveChanges()
{
SCH_SCREENS screenList( Schematic().Root() );
2017-09-20 14:20:38 +00:00
// Save any currently open and modified project files.
for( SCH_SCREEN* screen = screenList.GetFirst(); screen; screen = screenList.GetNext() )
{
SIMULATOR_FRAME* simFrame = (SIMULATOR_FRAME*) Kiway().Player( FRAME_SIMULATOR, false );
// Simulator must be closed before loading another schematic, otherwise it may crash.
// If there are any changes in the simulator the user will be prompted to save them.
if( simFrame && !simFrame->Close() )
return false;
if( screen->IsContentModified() )
2017-09-20 14:20:38 +00:00
{
if( !HandleUnsavedChanges( this, _( "The current schematic has been modified. "
"Save changes?" ),
2021-10-01 20:49:14 +00:00
[&]() -> bool
{
return SaveProject();
} ) )
2017-09-20 14:20:38 +00:00
{
2018-08-11 20:46:03 +00:00
return false;
2017-09-20 14:20:38 +00:00
}
}
}
return true;
}
bool SCH_EDIT_FRAME::updateAutoSaveFile()
{
wxFileName tmpFn = Prj().GetProjectFullName();
wxFileName autoSaveFileName( tmpFn.GetPath(), getAutoSaveFileName() );
wxLogTrace( traceAutoSave, "Creating auto save file %s", autoSaveFileName.GetFullPath() );
wxCHECK( autoSaveFileName.IsDirWritable(), false );
wxFileName fn;
SCH_SCREENS screens( Schematic().Root() );
std::vector< wxString > autoSavedFiles;
for( size_t i = 0; i < screens.GetCount(); i++ )
{
// Only create auto save files for the schematics that have been modified.
if( !screens.GetScreen( i )->IsContentModified() )
continue;
fn = screens.GetScreen( i )->GetFileName();
// Auto save file name is the normal file name prefixed with GetAutoSavePrefix().
fn.SetName( GetAutoSaveFilePrefix() + fn.GetName() );
autoSavedFiles.emplace_back( fn.GetFullPath() );
}
wxTextFile autoSaveFile( autoSaveFileName.GetFullPath() );
if( autoSaveFileName.FileExists() && !wxRemoveFile( autoSaveFileName.GetFullPath() ) )
{
wxLogTrace( traceAutoSave, "Error removing auto save file %s",
autoSaveFileName.GetFullPath() );
return false;
}
// No modified sheet files to save.
if( autoSavedFiles.empty() )
return true;
if( !autoSaveFile.Create() )
return false;
2021-10-17 23:29:10 +00:00
for( const wxString& fileName : autoSavedFiles )
{
wxLogTrace( traceAutoSave, "Adding auto save file %s to %s",
fileName, autoSaveFileName.GetName() );
autoSaveFile.AddLine( fileName );
}
if( !autoSaveFile.Write() )
return false;
wxLogTrace( traceAutoSave, "Auto save file '%s' written", autoSaveFileName.GetFullName() );
return true;
}
void removeFile( const wxString& aFilename, wxArrayString& aUnremoved )
{
wxLogTrace( traceAutoSave, wxS( "Removing auto save file " ) + aFilename );
if( wxFileExists( aFilename ) && !wxRemoveFile( aFilename ) )
aUnremoved.Add( aFilename );
};
void SCH_EDIT_FRAME::CheckForAutoSaveFile( const wxFileName& aFileName )
{
if( !Pgm().IsGUI() )
return;
wxCHECK_RET( aFileName.IsOk(), wxS( "Invalid file name!" ) );
wxLogTrace( traceAutoSave,
wxS( "Checking for auto save file " ) + aFileName.GetFullPath() );
if( !aFileName.FileExists() )
return;
wxString msg = _(
"Well this is potentially embarrassing!\n"
"It appears that the last time you were editing one or more of the schematic files\n"
"were not saved properly. Do you wish to restore the last saved edits you made?" );
int response = wxMessageBox( msg, Pgm().App().GetAppDisplayName(), wxYES_NO | wxICON_QUESTION,
this );
wxTextFile fileList( aFileName.GetFullPath() );
if( !fileList.Open() )
{
msg.Printf( _( "The file '%s' could not be opened.\n"
"Manual recovery of automatically saved files is required." ),
aFileName.GetFullPath() );
wxMessageBox( msg, Pgm().App().GetAppDisplayName(), wxOK | wxICON_EXCLAMATION, this );
return;
}
if( response == wxYES )
{
wxArrayString unrecoveredFiles;
for( wxString fn = fileList.GetFirstLine(); !fileList.Eof(); fn = fileList.GetNextLine() )
{
wxFileName recoveredFn = fn;
wxString tmp = recoveredFn.GetName();
// Strip "_autosave-" prefix from the auto save file name.
tmp.Replace( GetAutoSaveFilePrefix(), wxS( "" ), false );
recoveredFn.SetName( tmp );
wxFileName backupFn = recoveredFn;
backupFn.SetExt( backupFn.GetExt() + BackupFileSuffix );
wxLogTrace( traceAutoSave, wxS( "Recovering auto save file:\n"
" Original file: '%s'\n"
" Backup file: '%s'\n"
" Auto save file: '%s'" ),
recoveredFn.GetFullPath(), backupFn.GetFullPath(), fn );
if( !wxFileExists( fn ) )
{
unrecoveredFiles.Add( recoveredFn.GetFullPath() );
}
// Attempt to back up the last schematic file before overwriting it with the auto
// save file.
else if( !wxCopyFile( recoveredFn.GetFullPath(), backupFn.GetFullPath() ) )
{
unrecoveredFiles.Add( recoveredFn.GetFullPath() );
}
// Attempt to replace last saved file with auto save file
else if( !wxRenameFile( fn, recoveredFn.GetFullPath() ) )
{
unrecoveredFiles.Add( recoveredFn.GetFullPath() );
}
}
if( !unrecoveredFiles.IsEmpty() )
{
msg = _( "The following automatically saved file(s) could not be restored\n" );
for( size_t i = 0; i < unrecoveredFiles.GetCount(); i++ )
msg += unrecoveredFiles[i] + wxS( "\n" );
msg += _( "Manual recovery will be required to restore the file(s) above." );
wxMessageBox( msg, Pgm().App().GetAppDisplayName(), wxOK | wxICON_EXCLAMATION,
this );
}
wxArrayString unremovedFiles;
removeFile( aFileName.GetFullPath(), unremovedFiles );
if( !unremovedFiles.IsEmpty() )
{
msg.Printf( _( "The autosave file '%s' could not be removed.\n"
"Manual removal will be required." ),
unremovedFiles[0] );
wxMessageBox( msg, Pgm().App().GetAppDisplayName(), wxOK | wxICON_EXCLAMATION, this );
}
}
else
{
DeleteAutoSaveFile( aFileName );
}
}
void SCH_EDIT_FRAME::DeleteAutoSaveFile( const wxFileName& aFileName )
{
if( !Pgm().IsGUI() )
return;
wxCHECK_RET( aFileName.IsOk(), wxS( "Invalid file name!" ) );
if( !aFileName.FileExists() )
return;
wxTextFile fileList( aFileName.GetFullPath() );
wxArrayString unremovedFiles;
for( wxString fn = fileList.GetFirstLine(); !fileList.Eof(); fn = fileList.GetNextLine() )
removeFile( fn, unremovedFiles );
removeFile( aFileName.GetFullPath(), unremovedFiles );
if( !unremovedFiles.IsEmpty() )
{
wxString msg = _( "The following automatically saved file(s) could not be removed\n" );
for( size_t i = 0; i < unremovedFiles.GetCount(); i++ )
msg += unremovedFiles[i] + wxS( "\n" );
msg += _( "Manual removal will be required for the file(s) above." );
wxMessageBox( msg, Pgm().App().GetAppDisplayName(), wxOK | wxICON_EXCLAMATION, this );
}
}
const wxString& SCH_EDIT_FRAME::getAutoSaveFileName() const
{
static wxString autoSaveFileName( wxS( "#auto_saved_files#" ) );
return autoSaveFileName;
}