2021-10-14 13:20:54 +00:00
|
|
|
E-series are defined in IEC 60063.
|
2020-09-15 14:03:07 +00:00
|
|
|
|
2021-10-14 13:20:54 +00:00
|
|
|
Available values are approximately equally spaced in a logarithmic scale.
|
2020-11-03 04:03:36 +00:00
|
|
|
|
2021-10-14 13:20:54 +00:00
|
|
|
E24(5%): 1.0 1.1 1.2 1.3 1.5 1.6 1.8 2.0 2.2 2.4 2.7 3.0 3.3 3.6 3.9 4.3 4.7 5.1 5.6 6.2 6.8 7.5 8.2 9.1
|
|
|
|
E12(10%): 1.0 1.2 1.5 1.8 2.2 2.7 3.3 3.9 4.7 5.6 6.8 8.2
|
|
|
|
E6(20%): 1.0 - 1.5 - 2.2 - 3.3 - 4.7 - 6.8 -
|
|
|
|
E3(50%): 1.0 - - - 2.2 - - - 4.7 - - -
|
|
|
|
E1 : 1.0 - - - - - - - - - - -
|
|
|
|
|
|
|
|
- This calculator finds combinations of standard E-series (between 10Ω and 1MΩ) to create arbitrary values.
|
|
|
|
- You can enter the required resistance from 0.0025 to 4000 kΩ.
|
|
|
|
- Solutions using up to 4 components are given.
|
2020-11-03 04:03:36 +00:00
|
|
|
|
2021-10-23 07:44:47 +00:00
|
|
|
The requested value is always excluded from the solution set.<br>
|
|
|
|
Optionally up to two additional values can be excluded in case of component availability problems.
|
2020-09-15 14:03:07 +00:00
|
|
|
|
|
|
|
Solutions are given in the following formats:
|
|
|
|
|
|
|
|
R1 + R2 +...+ Rn resistors in series
|
|
|
|
R1 | R2 |...| Rn resistors in parallel
|
|
|
|
R1 + (R2|R3)... any combination of the above
|