* Create single event handler for grid size events.
* Fix all frame windows to use new grid size event handler.
* Use offset relative to ID instead of ComboBox index to save last grid size.
* Move last grid size load/save setting into WinEDA_DrawFrame.
* Add equality and assignment operators the GRID_TYPE.
* Add current grid helper methods to BASE_SCREEN.
* Add GetPins helper to LIB_COMPONENT to replace GetNextPin where applicable.
* Add AppendMsgPanel helper to WinEDA_DrawFrame.
* Improve rounding for display of coordinates when millimeter units are selected.
* Split out application specific command IDs to prevent unnecessary rebuilding.
* Eliminate duplicate menu and tool bar command IDs.
* Split component library editor and viewer definitions to separate header files.
* More component library and document file merge code.
* A bunch of minor string readability and consistency fixes.
* Add methods to read and write project file parameters using dynamically defined list.
* Remove all global variables defined in CVPcb code.
* Dynamically define project file settings so class member variables can be used.
* Separate reading and writing application settings from project file settings.
* Make application UI objects and dialogs respect system UI font.
* Remove non-standard widget colors from CVPcb dialogs.
* Changed CVPcb object link list implementation to use wxList.
* Changed project library and path dialog to make OK button save project file instead of confusing "Save Cfg" button.
* Eliminate some duplicate file wildcard and extension definitions.
* The usual code reformatting, commenting, and spelling fixes.
caused by prematurely deleting the module editor's m_Pcb pointer, which has the same value (points to the same structure) as
g_ModuleEditor_Pcb hence should not be
deleted.
================================================================================
+eeschema
* commiting my changes to allow multiple instances of a given schematic file within
a hierarchy:
** internally, m_currentScreen has been replaced with m_currentSheet,
which is a list or 'path' of screens. The path of screens is used to
generate
a series of timestamps, which is converted to flat component reference via
a look-up
table in the schematic files.
** this means that m_currentScreen is no longer used -- use GetScreen().
** GetScreen is virtual, as some of the dialogs keep around a WinEDA_BaseScreen
pointer.
** all sub-sheets in a given schematic must have different names to generate a
meaningful netlist.