jean-pierre charras 96a77d7618 Pcbnew: Add a min width parameter to plot solder mask layers.
* If this param is set to 0, the previous behavior is used.
* Else the solder mask is plotted as polygon, with shapes near than  this min width value are  merged.
Pcbnew in nanometer version: fix a serious rounding issue due to the fact dialogs were using 4 digits for mantissa.
* This is not enough for nanometer coordinates ( 8 are needed to display a value in inches),
*  so sometimes after closing a dialog, some coordinates were modified, although no new value was entered.
Minor other bug fixed.
2012-11-06 18:58:53 +01:00
Miguel Angel Ajo 9259b21ffa Footprint wizard converts from user units to internal units back and forth, so user can type in mm or mils now 2012-07-23 00:23:17 +02:00
jean-pierre charras e96f1aeb3d Remove valeur_param(), that does not work in Kicad Nanometer 2012-04-27 16:15:11 +02:00
jean-pierre charras fa3ebc4043 Define MM_TO_IU_SCALING_FACTOR (scaling factor from mm to internal units) only in convert_to_biu.h
Other scaling factors (MILS_TO_IU_SCALING_FACTOR and DECIMILS_TO_IU_SCALING_FACTOR)
also defined only in convert_to_biu.h.
Allows different scaling value for Gerbview.
Needs more tests.
2012-04-25 21:33:24 +02:00
Wayne Stambaugh bf5802f1f7 Removal of internal units.
* Remove internal units from BASE_SCREEN and it's derivatives.
* Remove internal units from EDA_DRAW_FRAME and it's derivatives.
* Use build time code to replace internal units conversions.
* Fix scaling bug in page layout sample window that I created in my
  last commit.
2012-04-16 19:31:29 -04:00
Wayne Stambaugh 6468805c27 More internal unit improvements.
* Move all convert from user to internal units into base_units.cpp.
* Remove internal units parameters from all moved conversion functions.
* Revise all source code that calls the moved conversion functions.
* Remove internal units from all dialog text control helper classes.
2012-04-16 13:39:32 -04:00
Wayne Stambaugh 8c0dc01fdd Pcbnew nanometer internal unit fixes.
* Scale page reference border and title block, grid sizes, and zoom factors
  correctly for nanometers.
2012-04-15 21:25:26 -04:00
Wayne Stambaugh 57d75a75a8 More internal unit improvements.
* Move all convert from internal to user units functions into separate file.
* Remove internal units parameter from all moved conversion functions.
* Revise all source code that calls the moved conversion functions.
* Compile these conversion routines separately for the appropriate pcb or
  schematic internal units.
* Move internal units specific status bar update code into the appropriate
  application for updating the status bar.
* Move millimeter user units rounding function to common.cpp.