Prior to this change, the schematic connectivity was updated any time a
change was made to a connectable object. Now the connectivity is only
updated when an object change actually affects the connectivity. Other
properties like line width, fill type, custom fonts, etc. will not cause
the connectivity graph to be rebuilt.
The SCH_COMMIT flag SKIP_CONNECTIVITY has been removed. All schematic
objects can test if they are connectable and if there have been changes
to any connection properties that require a connectivity rebuild.
Remove duplicate rebuild connectivity calls from editor control tool.
This was causing the tangling end test to get called four times on every
undo and redo action because the dangling end test is already called in
the connectivity graph calculation code.
Update connectivity when changing label names which fixes an unreported
connectivity bug.
Avoid O(N^2) by spatial sorting, don't run checks if the bounding boxes
don't overlap.
A second copy is ordered by type to help classes that only want to check
a few types having to walk the whole list.
Also fixes a bug where ERC testing for text variables in sheet pins
would start with the wrong sheet.
Also fixes a bug where ERC testing of similar labels would use the
wrong sheet.
Also fixes a bug where ERC testing of bus-to-net conflicts would use
the wrong sheet.
Also fixes a bug where ERC didn't process variable references when
checking hierarchical labels against sheet pins.
Also fixes a bug where ERC multiple-drivers and netclass-conflicts
tests didn't set a sheetpath.
While it's a bit of an encapsulation leak (see comment in
CONNECTION_SUBGRAPH::driverName()), it more than doubles undo/redo
performance in documents with *lots* of nets.
This is required to keep selected and brightened state across undo.
It's also probably required for things like IS_SHOWN_AS_BITMAP and
possibly ENTERED. FWIW, most BOARD_ITEMs do a straight swap, including
the temp and edit flags. But that seems like a risky change....
Also removes SyncView() call from Undo/Redo as that does a MODEL_RELOAD
which clears the selection.
- honor mirroring of fields attached to labels (all types)
- fix incorrect orientation of the graphic shape of SCH_DIRECTIVE_LABEL items
after mirroring the item.
Fixes#14758https://gitlab.com/kicad/code/kicad/issues/14758
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
Old PLOTTER::Text is not (yet) removed, but it use negative text size
to mirrored text, which is not really compatible with some plotters (especially PDF).
Using TEXT_ATTRIBUTES is much easy and much better,
so PLOTTER::PlotText() is added.
Note: "old" PLOTTER::Text() is not removed yet.
EDA_ITEMs are responsible for giving their parent a crack at it if
they failed to resolve it. This recurses all the way up to the schematic/
board, and then to the project.
Cross-reference handling is also move to the EDA_ITEMs. It must be done
before bubbling up so that we don't end up in loops. (The aDepth parameter
will break the loop, but without having done anything useful.)
Fixes https://gitlab.com/kicad/code/kicad/issues/13541
This is a special field, always existing, that cannot be handled like other fields.
Also avoid using translated names when initializing the field name.
Translated names can be used only in UI, not in internal data.
fixes#13113fixes#13125