Prior to fixing the schematic file change churn do to instance data
changing to the last selected sheet instance, the symbol instance data
was set rather than empty. This change allows for users to set the
default instance data which is used for every new instance of the
schematic.
ADDED: Default schematic symbol instance data (unit and reference, value,
and footprint fields) can be set to be used as the default settings
for all new instances of the schematic.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11113
Better to have both the single-pin error message and the non-driven
error message when an input pin is not connected than miss error
messages when the pin is connected to a blank net
Fixes https://gitlab.com/kicad/code/kicad/issues/10430
(cherry picked from commit e740db61f5)
Make "don't stroke" an explicit property in the GUI.
Silently enforce line width to >= 0 when stroking.
Make layouts between dialogs more consistent.
Interpret unspecified fill colour as layer colour.
Fixes https://gitlab.com/kicad/code/kicad/issues/11279
SIMULATOR has now an Attach() method, which should be called
with proper SIMULATION_MODEL that should be simulated, before calling Run()
Concrete class of SIMULATION_MODEL for ngspice is NGSPICE_CIRCUIT_MODEL,
renamed from NETLIST_EXPORTER_PSPICE_SIM. DIALOG_SIM_SETTINGS relies
on above mentioned object, so it was added as an argument of the constructor.
Do not use the symbol field string to populate the value and footprint
grid cells. The field strings may be empty because the symbol has not
been instantiated yet by entering a sheet. This fix makes an incorrect
assumption that the first instance value and footprint data in the symbol
is the same for all instances.
Note: this fix is incomplete because the value and footprint fields are
can now be different between sheet instances. The entire field
table editor design will need to be rethought because the current
grouping doesn't allow different value and footprint instance
changes.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11194
Also make sure that value field is updated from name changes when the
symbol is a power symbol (even if it's from the schematic instead of
the library).
Fixes https://gitlab.com/kicad/code/kicad/issues/11093
Double-calls are no longer needed when using settings. They can
interfere depending on how the system executes the commands.
Removing keeps the last used plugin as the default, rather than the last
selected
Fixes https://gitlab.com/kicad/code/kicad/issues/11094
(cherry picked from commit e8ef863861)
Adding a page in the ctor can generate events that change the default
page. Instead, we set the default after all pages have been added,
avoiding the reset
Fixes https://gitlab.com/kicad/code/kicad/issues/10910
(cherry picked from commit 5314ba6440)
It hasn't worked since we rejiggered the default grid selection mode
anyway, and for some reason it eats <esc> key events after the dialog
has been resized.
Fixes https://gitlab.com/kicad/code/kicad/issues/11015
Removes the ability to hide symbol units in file formats. This was
mostly the case for a while but there remained corner cases where we
left a default/hidden option
Fixes https://gitlab.com/kicad/code/kicad/issues/10888