We fake the alpha channel by pre-multiplying but we forgot to account
for the downscaling of the input channel value in addition to correcting
the alpha * white. This led to clipping when the values overflowed
Fixes https://gitlab.com/kicad/code/kicad/issues/14238
(cherry picked from commit d405fff1d8)
A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
(cherry picked from commit b41d446f58)
Old PLOTTER::Text is not (yet) removed, but it use negative text size
to mirrored text, which is not really compatible with some plotters (especially PDF).
Using TEXT_ATTRIBUTES is much easy and much better,
so PLOTTER::PlotText() is added.
Note: "old" PLOTTER::Text() is not removed yet.
From master, commit 51d46c0e73
Rather than hiding a single line at once, we align each word in the
string with the approximate location of the output word. This allows
better selecting text in the output pdf
Fixes https://gitlab.com/kicad/code/kicad/issues/12159
It might make sense to do that with board and/or schematic items for
hit-testing or something, but it definitely doesn't make any sense for
the drawing sheet border.
Also, when reading in items with a transparent fill, treat them as
unfilled (otherwise we get filled with layer colour in at least PCBNew).
Using arc angles to plot an arc is really error prone due to different
options between plotters, and angles defined in Kicad, using this version of
arc plotting from Kicad is no longer allowed in Kicad code.
Arcs are really error prone, due to different Y axis orientation, and geometry transforms.
Probably we should remove plot and print functions using arc angles as parameters
that are a can of worms.
Fixes#12465https://gitlab.com/kicad/code/kicad/issues/12465
(Not sure if it solves the MSW issues yet, but at least it highlights
the items in the dropdown on rollover on OSX.)
Also added some text to the dropdown menu for intersheet references in
the PDF.
Also moves most navigation code to SCH_NAVIGATION_TOOL.
Also changes page number href to anchor syntax ('#foo').
Also adds hypertext processing to SCH_TEXTBOXes.
Also adds combobox with schematic pages to text properties dialog.
The problem is that "real" page numbers can be duplicated, so we work around it
by using virtual page numbers instead which are guaranteed unique.
Example "goto:3" will go to page 3. If customised page numbers are used such as
a, b, c, then to go to page b, we should specify goto:2 (i.e. the virtual page
number).
Found via `codespell -q 3 -S *.po,./thirdparty,./Documentation/changelogs -L aactual,acount,aline,alocation,alog,anormal,anumber,aother,apoints,aparent,aray,ba,busses,dout,einstance,leaded,modul,ontext,ot,overide,serie,te,,tesselate,tesselator,tht`
The start/end point plotting is not reliable for eeschema. We need to
preconvert to angles to get the correct winding as the default plotter
conversion in the PLOTTER class makes pcbnew-based assumptions
Fixes https://gitlab.com/kicad/code/kicad/issues/11885