In the component, an m_unit/m_convert element is 1-indexed as opposed to
the library where they are 0-indexed. The 0-index in the library is
reserved for those elements that are shared across all conversion/unit
whereas it is invalid for the component.
Fixes: lp:1824764
* https://bugs.launchpad.net/kicad/+bug/1824764
Uses existing grouping in SVG output. Sets schematic components as a
grouped element in SVG as well as pcbnew elements per layer.
Fixes: lp:1011754
* https://bugs.launchpad.net/kicad/+bug/1011754
No dangling symbol for text items with a NO-CONNECT.
DanglingStateChanged doesn't work with dangling flag aggregators
(which return true if any child is dangling).
Then again, we don't actually use any of the aggregators anyway
so I removed them.
Fixes: lp:1799589
* https://bugs.launchpad.net/kicad/+bug/1799589
Support all symbol orientations. (Yes, SCH_COMPONENT said only the
first 8 were used, but it lied.)
Fix cases where SetTextAttributes() was overwriting previously-
set justifications.
Correct rotation of vertical text.
Fix issue where bold global label would affect thickness of next
label's outline.
Previously, when creating a new instance of a sheet, the full set of references
was cleared.
Moreover, if this sheet has sub-sheets, the annotation was incorrectly handled
Now only (and all) new sheet path(s) created have a reference cleared, as expected.
(new sheet paths can be more than one, if the new instance of the sheet has sub-sheets)
Fixes: lp:1789048
https://bugs.launchpad.net/kicad/+bug/1789048
... and GetMsgPanelInfo.
Step 4 in the g_UserUnit eradication effort.
Also removes a couple of conversion routines that were close
enough to extinction.
(cherry picked from commit c75da51)
Clearing annotations should only clear the settings that can be set by
the matching annotate function. Even in components where the units are
functionally the same, the unit choice should be retained as there are
often other considerations when chosing the unit.
Fixes: lp:1769457
* https://bugs.launchpad.net/kicad/+bug/1769457
1) Commit in-progress edits before closing preferences.
2) Handle default fields in Symbol Fields Editor.
3) Save state of checkboxes in Symbol Fields Editor.
Nets assigned by power pins are weak, meaning they are valid
as long as there is nothing else attached to such pins. This patch
checks whether there are other wires or pins attached to a power pin
before placing a global net label.
Fixes: lp:1755191
* https://bugs.launchpad.net/kicad/+bug/1755191
When an attempt to resolve a library symbol link having a library
nickname that was no longer found in the symbol library table, the
symbol resolution was not falling back to the cache library due to
a silently handled exception. Add check for valid symbol library
table nickname before attempting to resolve symbol link to prevent
exception bypassing falling back to the cache library.
Fixes lp:1740609
https://bugs.launchpad.net/kicad/+bug/1740609
Pins are weak_ptrs to the library, so they require a lock() before
accessing. This imposes a performance hit on fast loops that access
the pin list repeatedly. This patch caches the pin position locally
for each component, updating only when needed.
Fixes: lp:1737363
* https://bugs.launchpad.net/kicad/+bug/1737363
Show the NC box only on pins connected via the same component,
indicating a stacked pin group. Do not show NC box on pins for
different components with the same symbol.
If a schematic contains two symbols with the same name from different
libraries, the cache will contain the last symbol saved with that name.
Prepend the library nickname with the original schematic symbol library
nickname when saving the cache library to prevent name collisions.
All of the schematic object load and save code is implemented in the
legacy schematic plugin so it is no longer required.
Remove unused file with old schematic file loader.
Doxygen comment cleaning.
Move FindAlias() inside a try/catch block as is can throw an exception.
Don't abort adding symbols to library when a symbol cannot be found in
the symbol library table or the cache library. Instead, queue up error
messages and display them after attempting to add all of the symbols.
Always save the library file even if some of the symbols could not be
archived.
Catch IO_ERRORs in SCH_COMPONENT resolve to prevent unhandled exceptions
further up the stack.
Refactor rescue objects so that they can support derivation.
Factor out legacy rescuer code to perform legacy project rescues.
Create new symbol library table rescuer for rescuing symbol library table
based projects.
Perform the correct rescue type on project load.
Add symbol library table remapping support to the tools menu for run on
demand as applicable.
Add flag to SCH_SCREENS::UpdateSymbolLinks() to allow forcing the symbol
link updates when the library modification hash has not changed.
Check the if the schematic being loaded has been remapped (no symbol
library table nicknames defined) and remap accordingly.
Fix issues when resolving the library symbol links in the schematic
symbols.
Add cache library fallback when resolving symbols that cannot be
remapped.
Add remap complete message to remap dialog.
Add HasLibrary() helper to LIB_TABLE_BASE.
Fix issues when loading library symbols using symbol library table.
Add hashing function to symbol library table.
Improve the symbol panel message to warn user when cache library is
used to resolve symbol.