Scope: NETLIST_ITEM, CONNECTION_TYPE, ELECTRICAL_PINTYPE,
NET_CONNECTION, NETLIST_ITEM, GRAPHIC_PINSHAPE
Note, the pin type enum had PT_ added to the front to prevent
shadowing of the INPUT symbol on msys2 (see discussion at
c17c9960d8)
* Split up the thirdparty code into the thirdparty folder (#3637)
* Create a new kimath static library containing all the math functions
This is part of cleaning the build system for #1906.
* Fix not drawn shapes for clock low, inverted clock and broken shape for falling edge clock
* Especially, shape for falling edge clock was a not existing shape, therefore useless.
* now falling edge clock and clock low shape are similar.
Fixes: lp:1846901
https://bugs.launchpad.net/kicad/+bug/1846901
Bus upgrades: core new connectivity code
Bus upgrades: eeschema integration and modifications
Bus upgrades: eeschema dialogs
Bus upgrades: netlist export
Bus upgrades: file format changes
The standard DIM() macro was not typesafe as it happily deferred errors
to runtime that can be caught at compile time. Replacing it with a
generic C++11 constexpr allows for typecasting, comparison and compile
time error checking.
... and GetMsgPanelInfo.
Step 4 in the g_UserUnit eradication effort.
Also removes a couple of conversion routines that were close
enough to extinction.
(cherry picked from commit c75da51)
1) Edit Symbol gets similar fix as Place Symbol
2) progress dialog updating reduced to once every 50ms
3) SearchText gets lazy normalization
4) TypeNames get lazy translation
5) default fieldNames get translated a single time per language change
These fixes reduce first-load-time of both Edit Symbol and Place Symbol
by about 2/3, and second-load-time of Edit Symbol to near-instantaneous.
This is the last of the object save/load code that was not moved into
the SCH_LEGACY_PLUGIN object. All schematic and library I/O is now
performed in the SCH_LEGACY_PLUGIN object and as been removed from the
schematic and library objects.
The old single symbol file format has been replaced with the normal
symbol library file format since there was no difference between them
except the SYMBOL token. The SYMBOL token was no longer being read
since the introduction of the SCH_LEGACY_PLUGIN symbol library loader.
Update the Doxygen comments in all of the modified files.
This fixes a build error on MSVC. The code may actually be legal, but a
proof of that would require a lengthy dissertation on argument promotion
rules for the ternary operator, and the simplest rule of promoting both
cases to a wxString rvalue is not likely to be what is intended here.
Fortunately, this expression can be simplified.
- pad names are stored as wxString instead of a char[4] & integer union
- removed pad name to string conversion functions
- fixed pad & pin properties dialog restrictions regarding the name
length
eeschema now supports arbitrary colors for all object types, and
pcbnew does in GAL canvas. When switching from GAL to legacy canvas,
pcbnew will convert colors to the nearest legacy color.
Make all EDA_TEXT data private and rename accessors to avoid function
name collisions in derived classes.
Overload EDA_TEXT's SetTextAngle() and SetEffects() in TEXTE_PCB.
Add support for preserving Reference text position, size, orientation
during a netlist import into a BOARD, as well as the one off footprint
update dialog.