Remove duplicate sheet instance page numbering. It's already done when
the sheet is loaded from an exiting file or an already loaded schematic.
Remove the unnecessary page update code from the drawing tool.
The courtyards are referenced by multiple calls and will be rebuilt on
command. If this happens during zone fill (because the board timestamp
has incremented since the start) multiple threads may generate the cache
at the same time, leaving one with an invalid pointer
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17791
The arraystring reference is lost when we don't keep the wxFileName
variable in scope.
This also adds removing invalid paths and checking for correct version
before sorting
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17749
Ignore bus member connection subgraphs. They do not have a valid net
name nor do they contain schematic items. This prevents empty nodes
from being added to the tree. They can be reintroduced in the future
if someone wants to pursue it.
Freeze the wxTreeCtrl while populating it and thaw when done to prevent
any unnecessary repainting.
Add profiling to test how long it takes to rebuild the net navigator.
The recently added populate the navigator with all nets when no net
is highlighted has exposed some potential performances issues with some
versions of wxWidgets on certain platforms. Namely wxWidgets 3.2.4 on
Linux GTK.
Fix an issue where a sheet name change would not update the highlighted
net navigator resulting in a stale human readable sheet path.
Prevent the highlighted net navigator from being rebuilt twice when
loading a schematic. SCH_EDIT_FRAME::RefreshNetNavigator() was being
called from both SCH_EDIT_FRAME::UpdateHierarchyNavigator() and
SCH_EDIT_FRAME::RecalculateConnectivity().
Add a new trace helper "KICAD_UI_PROFILE" to show trace output when
profiling user interface performance. It's used in the net navigator
profiling mentioned above.
Reuse PROF_TIMER::Show() to generate string for PROF_TIMER::to_string().
Previously, we only allowed pins of the same time as well as passive
pins to be stacked. This change allows NIC pins as well since they are
not internally connected, there is no reason that they cannot be tied to
another pin electrically
- Component name ref comes before pin ref
- OtherSideView is at the end of the package
- BOM defines the dictionary so we need all items in the BOM even if
marked "Exlude from BOM"
- Fix unique REFDES indicator to increment number rather than appending
additional numbers
Don't try to do too many things at once. Separate
out fooptrint-children handling, visibility-handling,
and footprintEditor vs boardEditor differences.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/17562
The schematic net names are fully unique but if we have multiple pads
that are mapped to a NC pin, they need to have unique net names so that
they do not get connected to each other in the ratsnest. This breaks
the schematic parity check as we have modified the netname for some
pads. To work around this, we first maintain the zero-th net without
suffix and then add an additional check in DRC to ensure that we allow
unconnected nets as long as the share a common prefix with the schematic
netname.