Note that "immediate" doesn't mean quite the same thing: while it will
enter the tool immediately, it won't necessarily finish the tool during
the call if the tool has an event loop. So for something like Rotate
"immediate" and "synchronous" have the same behaviour, but for something
like Move they do not.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/15085
Using a boolean argument just leads to a lot of trailing booleans in the
function calls and is not user friendly. Instead, introduce PostAction()
to send an action that runs after the coroutine (equivalent to passing
false or the default argument), and leave RunAction as the immediate
execution function.
Also fixes a bug where Convert Symbol wasn't undoable.
Also cleans up some SetModified() call no longer needed with SCH_COMMIT.
Also fixes bug where revert of a modification didn't update the screen's
RTree.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/15030
The connection graph should only be updated within the commit structure
because this is the only time the connectivity should be changed. We
want any connectivity changes to be included in the commit as well, so
this should be stored prior to the undo/redo list mods
Use COMPARE_FLAGS::EQUALITY and COMPARE_FLAGS::ERC when doing
library diffs.
Also fixes a few more cases where we weren't checking for -1 when
doing a fieldID < MANDATORY_FIELDS.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/14830
SCH_CONNECTION objects are temporary and can become stale any time the
connectivity is updated. Keeping them around to reference later is a
bad idea. Even if the object pointer is still valid in an SCH_ITEM in
the undo/redo buffers, comparing the pointer against another pointer as
a test to see if they are the same connection is not valid. Saving the
connection name is safe and ensures the connection is the same even if
the pointers differ.
- Ensure the first field in m_fields has id = 0 to be seen has hypertext
(it was not the case after reading a .kicad_sch file)
- when converting this item to another label/text, remove this special Field
from the copied field list to the converted label.
SCH_EDIT_FRAME::RecalculateConnections() calls SchematicCleanup and then
resets the connectivity graph and recalculates it. OnModify() also
calls RecalculateConnections(). For long calculation schematics, this
can impact usability
1) Copy label fields when converting.
2) Don't assume netclass directive should be net name -- this is very
unlikely.
3) Don't show font controls in Netclass Directive Properties dialog --
there's no basic text associated witha Directive Label.
We're getting segfaults in places where this isn't checked. Also, add
some asserts so we can catch bad tool push/pop.
Removes all uses of GetCommandStr() and makes it private.
dropping files to Kicad manager :
*.kicad_pro, *.pro -> open project;
gerber and job files -> open in Gerbview editor;
Eagle and Cadstar files -> open project.
dropping file to schematic editor -> append schematic;
dropping library file to Symbol editor -> add library;
dropping board file to PCB editor -> append board;
dropping library or footprint file to Footprint editor -> add library or import footprint;
dropping ZIP file or gerber files to Gerbview editor -> open files;
dropping sheet file to Drawing Sheet editor -> open sheet.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11638