Also removes the message bar display of assigned netclass for
buses and bus-to-bus entries.
Also fixes a bug where assigning a netclass via the canvas only
looked at the first level of bus members (and not any nested
members).
Also fixes a bug where the bus name validator tried to validate
a vector bus first -- which doesn't work as a vector bus may be
nested in a group bus.
Also fixes a bug where we were failing to check for illegal
chars in bus definitions which otherwise passed the bus parsers.
See additional comments in the bug report.
Fixes https://gitlab.com/kicad/code/kicad/issues/9160
1) Fix a couple of bugs in case processing
2) Make case processing more explicit to prevent more (1)
3) Move label processing to AltiumSpecialStringsToKiCadVariables
4) Strip double-quotes from special strings (and add test cases)
5) Change PROJECTNAME to just filename, not full path
6) PROJECTREV and REVISION are two different things
7) Add support for Altium's Application_BuildNumber
8) Fix some issues in trimming spaces around special strings
ADDED CURRENT_DATE titleblock token (to go with existing ISSUE_DATE)
ADDED PROJECTNAME schematic token (to go with FILENAME and SHEETNAME)
Converts other parameters to project text variables.
- new function SCH_SHEET_LIST::SortByPageNumbers() which uses SCH_SHEET::ComparePageNum for the sorting algorithm
- SortByPageNumbers() is called after every call to BuildSheetList()
The groundwork has now been laid for per sheet instance data. Initially
this only supports sheet page numbers but could be expanded to include
other per sheet instance information.
ADDED: Support for user defined schematic page numbers.
Short net names are not unique; full names with paths must be used.
Added a grid cell renderer that does the escaping, to make it easier
to display net names in grid cells.
Once you unescape a net name, you can't go back to the escaped form
because you can't assume which `/` should be {slash} and which `/`
Because of this, we cannot use Unescape/Escape on the data model in
the netclass setup panel, and instead do the Unescape in the view.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/5331
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of. Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.