The BuildSteps folder now contains the CMake scripts that are
called during the build process as individual stages, while
the root CMakeModules directory contains the CMake files used
during the configuration phase.
This unifies everything under a single architecture with a "don't
show again" dialog. Since everything now goes through the same
path it should be reasonably easy to make it do whatever we want
in the future.
Right now it presents 3 options: modify only unlocked items, override
locks and modify all items, or cancel command.
This commit adds the PCB_ORIGIN_TRANSFORMS class, which is derived
from the ORIGIN_TRANSFORMS class, and provides a set of templated
functions to convert PCB coordinates between internal representation
and display representation. It extends the ORIGIN_TRANSFORMS class
to understand the three user-selectable display origins and the
coordinate direction display options.
This commit adds the ORIGIN_TRANSFORMS class to support Display Origin
Transforms in all KiCad applications.
Functions are provided to perform four basic types of origin coordinate
transforms:
* Transform a relative coordinate from internal to display form
* Transform a relative coordinate from display to internal form
* Transform an absolute coordinate from internal to display form
* Transform an absolute coordinate from display to internal form
These functions are supported for data types "int", "long long int",
and "double". The default implementations for all but "int" simply
return their input unchanged; the implementation for "int" invokes
the implementation for "long long int".
The expectation is that the different KiCad applications will create
derived classes from this base class and override the functions as
needed. Protected template functions are provided for the standard
translations to maintain consistency within the derived classes.
Short net names are not unique; full names with paths must be used.
Added a grid cell renderer that does the escaping, to make it easier
to display net names in grid cells.
Once you unescape a net name, you can't go back to the escaped form
because you can't assume which `/` should be {slash} and which `/`
Because of this, we cannot use Unescape/Escape on the data model in
the netclass setup panel, and instead do the Unescape in the view.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/5331
* Frames moved: cvpcb, cvpcb footprints frame, gerbview, pagelayout editor
This also introduces new EDITOR_CONDITIONS that are used to set the
conditions of very common editor settings.
Also, some IDs were converted to tools in the pagelayout editor.