A sheetpath is required to correctly resolve text variables.
Depending on currentSheet is rife with bugs.
There are many places where we do *not* want to be prepending
field names to the field values, such as netlisting,
building PDF hypertext menus, etc.
Also, Find/Replace needs to work on unresolved text, as
that's what we're going to display (and if replace nuked
your variable references you wouldn't be happy).
(cherry picked from commit b41d446f58)
The netlist exporter was never updated to exclude symbols that are
tagged as power symbols. Only the legacy power symbol name prefix
('#') was used as the power symbol check. Power symbols no longer
require the '#' name prefix.
(cherry picked from commit fb6b8eaeea)
The list of candidates (names) must be restricted to existing global labels
and symbols creating a global net name: power symbols having only one power
input pin (a power output does not create net name).
Fixes#14319https://gitlab.com/kicad/code/kicad/issues/14319
Also adds simulation model inference to Symbol Editor's Simulation Model
Editor, and adds write-back from both Simulation Model Editors to their
parent Symbol Fields Editor dialogs.
Fixes https://gitlab.com/kicad/code/kicad/issues/12505
This will make it possible to maintain sheet instance information when
copying and pasting from any sheet other that the root sheet of a
project.
Setting and getting sheet page numbers must now be performed using a
sheet path. This was done to ensure that the instance paths were not
getting changed unexpectedly from different code paths.
Eeschema shows background fills on a different z-level than the rest of
the symbols/elements. Print the backgrounds prior to the foregrounds in
order to preserve this view for print output
Fixes https://gitlab.com/kicad/code/kicad/issues/12559
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Added project name to instance data to improve the readability of the
schematic file format. It also creates an opportunity to remove orphaned
instance data by project name rather than cryptic UUIDs.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
This change reverts the storage of all symbol instance data in the root
schematic. This was done because it's not possible to reuse instance
data when importing from sub-sheets.
There has been a fundamental change in how sheet paths are store in the
instance data. The root schematic UUID is always used when saving the
instance data. To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project. This provides a way
to determine the project that stored the instance data. All uses of paths
without root sheet have been expunged from the code.
The sheet instance data is still saved only in the root sheet for the
time being. New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number. Sheet page
numbers will not be imported.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
Pass the current SCHEMATIC object pointer in SCH_SYMBOL ctor so that
newly created symbols will update the current instance data on creation
when the current sheet instance is being displayed.
This is a better fix for the master branch and cherry-picking from 6.0
was a mess.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/12190
This change removes the incorrect assumption that symbol pin numbers are
integers and are the same as indexes in the vector storing the symbol
pins.
"~" is now used to denote a floating sim model pin.
Implemented serialization and deserialization of models in symbol fields
through the SIM_VALUE class. We don't carry the Spice legacy of
case-insensitive suffixes, instead we conform to the SI standard (i.e. M
is Mega, not milli, P is peta, p is pico).
Parameter grid value validation is implemented by simply not allowing
any characters that will make the value invalid (instead of highlighting
the field in a red color). This will likely be changed at some point in
the future.
Prior to fixing the schematic file change churn do to instance data
changing to the last selected sheet instance, the symbol instance data
was set rather than empty. This change allows for users to set the
default instance data which is used for every new instance of the
schematic.
ADDED: Default schematic symbol instance data (unit and reference, value,
and footprint fields) can be set to be used as the default settings
for all new instances of the schematic.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11113
Removes the ability to hide symbol units in file formats. This was
mostly the case for a while but there remained corner cases where we
left a default/hidden option
Fixes https://gitlab.com/kicad/code/kicad/issues/10888
ADDED arc, circle and rectangle shapes for schematic. Shapes support
line styles and fill colors.
CHANGED sheet background color in Edit Text & Graphics Properties to
fill color (and it now affects shapes).
Pushed STROKE_PARAMS down into common and moved all shapes to using it
for stroke descriptions.