Commit Graph

317 Commits

Author SHA1 Message Date
dickelbeck 3bb1764dff delete track uses dirty rect 2008-03-10 15:00:22 +00:00
lifekidyeaa 0dc3be8806 added an option to enable/disable magnetic tracks in the general options dialog of PCBnew (same as the magnetic
pads option.)  Haven't fixed the via issue 
(since I don't quite understand why it is doing this, nor does it occur in 100% of the cases), but now you can just 
turn 
off magnetic tracks when I desire to move vias by small increments.  Magnetic tracks are on by default.  Original 
via complaint here: 
http://tech.groups.yahoo.com/group/kicad-devel/message/1155

Also mostly gotten rid of the annoying "Unable to drag this segment: two collinear segments" error.  Now, if two 
(or more) segments are collinear, they are merged into one equivalent segment when you try to drag them while 
maintaining slope.  I can't imagine any cases where this would be a bad thing (and I have plenty of experience where 
the error was not desired!).  Note I say *mostly* because there still seem to be some length=1 (e.g. 0.003mm) segments 
at the end of valid-length segments.  I do not want to remove them because this would change the board layout, though 
in a basically imperceptible way.  We could maybe have an option to clean & remove these minimal-length segments, but 
I worry that they serve to connect things slightly off grid & those things on-grid; also, removal may cause DRC 
errors. It would be good if we could avoid their creation.(?)
2008-03-04 05:40:15 +00:00
dickelbeck 10e13ae50a layer names in *.brd file 2008-03-04 04:22:27 +00:00
lifekidyeaa c5cd85027b 2008-Feb-12 UPDATE Tim Hanson sideskate@gmail.com
================================================================================
+eeschema
        * commiting my changes to allow multiple instances of a given schematic file within 
a hierarchy:
        ** internally, m_currentScreen has been replaced with m_currentSheet,
                which is a list or 'path' of screens.  The path of screens is used to 
generate
                a series of timestamps, which is converted to flat component reference via 
a look-up
                table in the schematic files.
        ** this means that m_currentScreen is no longer used -- use GetScreen().
        ** GetScreen is virtual, as some of the dialogs keep around a WinEDA_BaseScreen 
pointer.
        ** all sub-sheets in a given schematic must have different names to generate a 
meaningful netlist.
2008-02-12 21:12:46 +00:00
dickelbeck cf460637b2 beginnings of the 2 specctra imports 2008-02-06 22:32:15 +00:00
CHARRAS 7055a2bc47 zone outlines edition: added drag outline edge 2008-02-01 21:30:45 +00:00
CHARRAS af445e70ea remove the old EDGEZONE class. Cleaning code in polyline.x 2008-01-31 20:53:44 +00:00
CHARRAS 9ba9be706e void Change_Side_Module( MODULE* Module, wxDC* DC ) is now member of class BOARD (as asked in todo list) 2008-01-25 13:16:24 +00:00
CHARRAS bbae2b12b1 Plot option in GERBER format Plot (Exclude Edge Pcb layer) modification (now, default = off, and saved in config) 2008-01-23 08:01:38 +00:00
dickelbeck 8d79a82b3d specctra export support 2008-01-21 22:16:45 +00:00
CHARRAS e9b3322fc0 On line DRC when creating a zone outline 2008-01-20 19:55:22 +00:00
CHARRAS f85ade75d8 see changelog 2008-01-16 20:37:50 +00:00
CHARRAS 0120f07d54 code cleaning 2008-01-06 17:19:36 +00:00
CHARRAS 97be005035 Added: Delete cutout outline in zone popup menu 2008-01-05 13:37:51 +00:00
CHARRAS ffd3a7133a more about zones. current No DRC for outlines 2008-01-04 12:27:16 +00:00
raburton ed4b90151c set eol-style native on new files 2008-01-01 11:58:14 +00:00
CHARRAS 62a28440e0 wxstruct modified and wxPcbStuct.h added. some minor other changes 2008-01-01 11:46:47 +00:00