Don't use the value field when adding Eagle part attributes to a symbol.
This issue was cause by using a mandatory symbol field ID instead of
using the next available field ID when adding new fields to as symbol.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13468
Earlier commit moved variable substition earlier (in loadSymbolText())
so we didn't have the correct info later when we tried to do the
special processing on it.
Fixes https://gitlab.com/kicad/code/kicad/issues/13541
We only need to parse the libraries for the Sim Model Editor dialog
(so that we can determine the models to put in the popup). Doing it
for netlisting just opens us up to incorrectly parsing the SPICE, and
returns no value.
This also means that a SIM_LIB_MGR manages a single library, and
never multiple libraries.
This also allows the tidying-up of some error reporting structures to
better inform the user what went wrong.
Fixes https://gitlab.com/kicad/code/kicad/issues/13431
Changes architecture of importer to use SHAPE_LINE_CHAIN.
For now lets just load symbol shapes like this, but we could update code
for all other loading operations (also in PCB).
FIxes https://gitlab.com/kicad/code/kicad/-/issues/8060
Eagle schematics do not show the value field when it's not defined or
when not package (footprint) is defined for the symbol which is the
case for power symbols. Don't show the value field in KiCad to bring
the view more in line with what Eagle displays.
Inspired by Stefan's merge request #13433.
Fixes: https://gitlab.com/kicad/code/kicad/-/issues/13433
Check for already loaded schematics in the current sheet path as well
as the current project root sheet path to prevent multiple loads of
shared schematic. This bug was causing shared sheets to be loaded more
than once which caused instance data to get separated by each copy rather
than saved in one copy of the schematic which would result in all instance
data being lost except the last saved copy of the schematic. This bug has
been around forever and may be the cause of some unexplained schematic
instance data corruption issues. This bug does not apply when opening
the full project.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11076
This is a special field, always existing, that cannot be handled like other fields.
Also avoid using translated names when initializing the field name.
Translated names can be used only in UI, not in internal data.
fixes#13113fixes#13125
Shared schematics can have a root sheet instance when opened with the
schematic editor in stand alone mode. This would cause a crash when
opening the shared schematic in a project where it was shared because
the root instance was trying to be saved in the normal sheet instance
data which is not valid.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13102
The crash was caused by an unhandled exception. The uncaught exception
caused a cacophony of null configuration setting pointers so guards were
added to prevent crashes should other exceptions occur that do not get
handled correctly.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13046
... to netclass flags. They're now directive labels and the netclass
field isn't auto-added anymore. However, we *do* auto-add an intersheet
refs field, and that's required.