1) Don't plot all footprint texts for each footprint graphic item.
2) Enforce min web thickness around board shapes and board text.
3) Enforce min web thickness around footprint shapes
4) Correctly handle multi-layer zones.
(1) and (4) will get cherry-picked back to 6.0, so after rebasing
won't actually appear in this changelist anymore....
CHANGED: Settings are now stored in versioned sub-directories
ADDED: First-run dialog for migrating settings from a previous version
CHANGED: Settings are now stored as JSON files instead of wxConfig-style INI files
CHANGED: Color settings are now all stored in a separate settings file
CHANGED: The symbol editor and footprint editor now have their own settings files
CHANGED: Color settings are no longer exposed through BOARD object
CHANGED: Page layout editor now uses Eeschema's color scheme
Settings are now managed through a central SETTINGS_MANAGER held by PGM_BASE.
Existing settings will be migrated from the wxConfig format on first run of each application.
Per-application settings are now stored in one class for each application.
* Split up the thirdparty code into the thirdparty folder (#3637)
* Create a new kimath static library containing all the math functions
This is part of cleaning the build system for #1906.
eeschema now supports arbitrary colors for all object types, and
pcbnew does in GAL canvas. When switching from GAL to legacy canvas,
pcbnew will convert colors to the nearest legacy color.
This option is not yet activated because the net attributes are not yet fully fixed by Ucamco, in Gerber file format specifications.
(To activate it, see dialog_plot.cpp, line 43)
Pcbnew: Plot files: for copper layers, create suffix from user copper layer names instead of default copper layer names, like in last stable Kicad version (bzr 4022), to build the plot files filenames.
Better test of illegal chars in plot filename, both in plot dialog and functions aclled by Python scripts.
Fix a Plotcontroller issue to make SetUseGerberExtensions() work as expected from Python scripts ( from Henner Zeller'patch with a fix to be sure it works properly from a Python script)
Note also using Protel Gerber Extensions is now a bad practice, because the official Gerber extension is .gbr since X2 Gerber version. But some users still use them)
2) Change from legacy Cu stack to counting down from top=(F_Cu or 0).
The old Cu stack required knowing the count of Cu layers to make
sense of the layer number when converting to many exported file types.
The new Cu stack is more commonly used, although ours still gives
B_Cu a fixed number.
3) Introduce class LSET and enum LAYER_ID.
4) Change *.kicad_pcb file format version to 4 from 3.
5) Change fixed names Inner1_Cu-Inner14_Cu to In1_Cu-In30_Cu and their
meanings are typically flipped.
6) Moved the #define LAYER_N_* stuff into legacy_plugin.cpp where they
can die a quiet death, and switch to enum LAYER_ID symbols throughout.
7) Removed the LEGACY_PLUGIN::Save() and FootprintSave() functions.
You will need to convert to the format immediately, *.kicad_pcb and
*.kicad_mod (=pretty) since legacy format was never going to know
about 32 Cu layers and additional technical layers and the reversed Cu
stack.