The default hotkey is Ctrl+L, as this is not bound by
default in the FP or symbol editor, and it is the hotkey
that is used to focus the address bar in web browsers,
which is a similar kind of action.
Previously, although the fp editor preferences has an option to select the canvas type,
it was read from the the PCBNEW_SETTINGS config, using Kiface().KifaceSettings().
When editing or viewing library symbols, the files are watched for
underlying changes. If any occur, the user is either prompted to reload
(if reloading would overwrite their current edits) or the file is
silently updated to the current version on disk.
This also sets a custom assertion handler to avoid unneeded crashes when
recieving invalid SAMBA packets and turns off assertions entirely when
running in release (non-debug) mode
As of wxWidgets 3.2, the wxWidgets event handler runs code after the
the client event handler that depends on the menu still existing.
Because there are potentially many paths to call ReCreateMenuBar from
within a menu event handler, let's just wrap this action in a CallAfter
to make sure it happens after the wx handler call completes.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/13149
The value of this rotation was store in 2 places: the config and the editor frame.
So after changing the rotation angle from the preferences, the value in editor
frames were not updated, and the rotation angle not modified.
Now only the config value is used.
This code was shared between the footprint frame and
pcb edit frame, so push it into the base edit frame.
Also remove the dummy wxUpdateUIEvents that weren't
actually being used.
One way to do this would have been to keep the Uuids in the editor
copy. However, this opens us up to errors if we forget a Save As or
export path and end up writing the Uuids out somewhere else.
In the end, it felt safer to store a map of the original Uuids and
restore them if we happen to save the editor footprint back to the
board.
Fixes https://gitlab.com/kicad/code/kicad/issues/7312
CHANGED: GetDocumentExtents() in 'eda_draw_frame.h' now has a bool
parameter "aIncludeAllVisible" with a default value "true" which makes
it behave as it did before adding parameter. If "aIncludeAllVisible"
is false, the returned bbox ignores some items depending on which
program it is running in.
CHANGED: Made "Zoom to Objects" use only PCB edge in Pcbnew. This
allows text, notes, etc outside the PCB edge to be excluded in the
zoom calculation.
CHANGED: Added "Zoom to Objects" to Pcbnew main menu, and to RMB context
menus for Eeschema and Pcbnew.
Fixes https://gitlab.com/kicad/code/kicad/issues/5787