Commit Graph

66 Commits

Author SHA1 Message Date
Wayne Stambaugh 0a62c17040 Remove schematic symbol value and footprint field instance data.
https://gitlab.com/kicad/code/kicad/-/issues/12933
2022-11-30 11:47:13 -05:00
Alex 58b03b0a1c Small optimizations. 2022-09-22 17:22:04 +00:00
Jeff Young 64a6fc0fd4 Push UNITS_PROVIDER down into a low-level mixin.
This allows us to also construct cheap UNIT_PROVIDERs for specific
tasks when necessary.
2022-09-19 17:10:59 +01:00
Mark Roszko b00178adb3 Nuke base_units from orbit 2022-09-16 04:38:10 +00:00
Seth Hillbrand 16479277cc Catch connection errors when stacked pins have NC flags
Don't flag the error as having a connected net with an NC flag.  Stacked
pins are not connected in that sense, so are allowed an NC flag
2022-09-09 17:21:57 -07:00
Jeff Young f17a865593 Move EDA_ITEM hitTest to BOX2I. 2022-08-31 17:18:45 +01:00
Jeff Young 2dc6300501 Move EDA_ITEM bounding boxes to BOX2I. 2022-08-31 10:16:55 +01:00
Marek Roszko bf964d8678 Commonize page_info by simply making the Iu scale a parameter on call. 2022-08-27 13:36:00 -04:00
Marek Roszko e0f28fc4e1 Replace wxFindReplaceData with our own container
By dropping the flags, we can be strict with options.
Also it makes future usage of search functionality a little more "UI" framework independent
2022-08-23 22:16:51 -04:00
Jeff Young 1f347582f8 Introduce new marker type so we can track DRC errors on the drawing sheet.
Fixes https://gitlab.com/kicad/code/kicad/issues/12221
2022-08-15 18:03:03 +01:00
jean-pierre charras b5c83ffd95 Eeschema, slash in power pin name: better fix than commit ba7a06f5.
ba7a06f5 tried to fix a (minor) issue in net names when the name was coming
from a input power pin having a '/' in name. But ba7a06f5 blindly escaped any '/'
in net name, and the hierarchy info was lost.
Now only the pin name is escaped (like any other pin name used in net names)
2022-08-10 11:00:19 +02:00
Jeff Young 3def3d659e Allow click-selection and greedy-drag selection of visible pin text.
Stingy drag still works only on the pin itself.

Fixes https://gitlab.com/kicad/code/kicad/issues/11723
2022-07-23 23:27:14 +01:00
Alex c6d9dcdad5 Schematic editor: allow box-selecting pins. 2022-07-18 18:51:52 +00:00
Jeff Young 45ab15dc95 Use unit references in status bar.
Fixes https://gitlab.com/kicad/code/kicad/issues/11854
2022-06-19 12:54:30 +01:00
jean-pierre charras 50b68df666 Eeschema, SCH_PIN: fix incorrect initialization of m_layer member (now is LAYER_PIN)
m_layer was not re-initialized in CTOR, so it was the default value (LAYER_WIRE)
This is incorrect for a pin, and can create errors in some functions (like IsType() )
Fixes #1818
https://gitlab.com/kicad/code/kicad/issues/1818
2022-06-17 11:01:49 +02:00
Jeff Young 6114a5d72c Escape pin names when used as netnames.
Fixes https://gitlab.com/kicad/code/kicad/issues/11687
2022-05-26 23:54:55 +01:00
Marek Roszko c4c56de708 Neurotically update position wxPoint usages 2022-01-01 11:55:51 -05:00
Jeff Young e48d4a653a Pick better auto-generated netnames.
Fixes https://gitlab.com/kicad/code/kicad/issues/4312
2021-12-24 18:13:16 +00:00
Jeff Young 8b52e969d6 Restore units to a bunch of wxGrids.
Fixes https://gitlab.com/kicad/code/kicad/issues/10063
2021-12-23 16:54:03 +00:00
Jeff Young 2e342ed8c9 Draw dangling symbols on a separate layer.
This allows us to draw them in front of wires, pins, and most
importantly, junction dots.

Fixes https://gitlab.com/kicad/code/kicad/issues/9667
2021-12-06 18:50:50 +00:00
Mikolaj Wielgus 71bfbfaa70 Test SCH_PIN rotation and mirroring 2021-11-28 19:37:13 +01:00
Jeff Young 7fc04c3cf2 Fixes for realtime connectivity being off.
Fixes https://gitlab.com/kicad/code/kicad/issues/9628
2021-11-24 13:20:44 +00:00
Jeff Young f73042fe24 Some minor performance enhancements. 2021-09-28 14:28:35 +01:00
Jeff Young 5f3c67bd2b Fill in some missing GetMsgPanelItems and make some others consistent.
Also expunges a std::vector<MSG_PANEL_ITEM> cover type.
2021-09-27 00:23:40 +01:00
Jeff Young a5c4bace60 Improve (and simplify) wire and pin hit-testing.
1) Expand the accuracy to at least the grid spacing
2) Move pin-selects-symbol logic to Selectable()
3) Recode pick-closest algorithm to handle exactHits and inexactHits
separately
4) Remove pin target from bounding box in favour of expanding it to
at least as wide as the pin decoration (this prevents the accuracy
off the end of the pin from growing too large)
2021-09-19 11:34:43 +01:00
Jeff Young 24e54178db Make sure pin hittest regions don't get too hard to hit.
Fixes https://gitlab.com/kicad/code/kicad/issues/8616
2021-07-01 15:43:19 +01:00
Jeff Young 0484ca5564 Separate LIB_PIN and SCH_PIN GetShownName/Number processing.
SCH_PIN wasn't handling the legacy empty string token (~), but
more importantly this will allow text variable resolution specific
to the schematic.

Fixes https://gitlab.com/kicad/code/kicad/issues/8625
2021-06-17 10:52:46 +01:00
Jeff Young bcdec0dea7 Move '~' pin name processing to LIB_PIN and SCH_PIN.
This will also allow us to do variable processing in the future if
desired.
2021-06-12 19:54:34 +01:00
Wayne Stambaugh fbc135e69f Rename SCH_COMPONENT to SCH_SYMBOL. 2021-06-10 10:34:49 -04:00
Wayne Stambaugh 1786ae8773 Eeschema: use symbol nomenclature for object file naming. 2021-02-24 08:48:02 -05:00
jean-pierre charras 658a5cf7ed SCH_PIN::GetMsgPanelInfo(): fix missing initialization of Pin Number string
The displayed string was a old value, not related to the Pin Nummber
Fixes #7414
https://gitlab.com/kicad/code/kicad/issues/7414
2021-02-04 11:14:46 +01:00
Jeff Young 0ba0160da9 Add a PT_NIC pin electrical type and a netlist token for SCH_NO_CONNECT.
ADDED a new pin electrical type "free" for internally unconnected pins.

CHANGED the "unconnected" pin electrical type is now represented by
"no_connect" in files and netlists.  (The legacy syntax is also accepted
in files.)
2021-01-23 00:10:01 +00:00
Jeff Young 10c6e0bc46 Cache entries are dependant on setting of aForceNoConnect
Don't use a result cached when aForceNoConnect was false when
aForceNoConnect is true.
2021-01-23 00:10:01 +00:00
Jon Evans 02681fcf0e Move no-connect processing to connection graph
This way the net names can be inspected in eeschema and cross-probing works.
Testcases updated for the name changes

CHANGED: all unconnected pins are now included in the netlist with no_connect_ prefixes
2021-01-14 20:55:49 -05:00
Dominik Wernberger ec0af24f13 Make wxFindReplaceData argument const 2021-01-12 20:51:31 +00:00
Jeff Young c1d1c12b41 Simplify message panel code.
We've had the colours turned off for two releases now without any
screaming or gnashing of teeth, so it's time to clean up the code.
2020-11-18 17:32:40 +00:00
Jeff Young c89676e39d Require client to specify whether they want resolved values or not.
Fixes https://gitlab.com/kicad/code/kicad/issues/6408
2020-11-17 21:36:48 +00:00
Jeff Young b227d2b910 More component -> symbol. 2020-11-15 20:23:15 +00:00
Jeff Young 6654c03041 Embarking on the next adventure: component -> symbol. 2020-11-15 20:23:15 +00:00
Jeff Young a6d4ce2a5c Finish impl of alternate pins.
It appears this got shelved while waiting for the sexpr format to be
firmed up, and then I forgot about it.

Fixes https://gitlab.com/kicad/code/kicad/issues/6189
2020-10-28 13:01:42 +00:00
Jeff Young 4565631728 Finish moving eeschema assigned netclasses to sheet-path-relative.
Also adds code for the case where a new label is created on a net
with an existing netclass assignment.

Fixes https://gitlab.com/kicad/code/kicad/issues/5886
2020-10-07 16:31:55 +01:00
Mikolaj Wielgus 400c15b8eb Add mils to units, remove useMils variables 2020-10-03 20:06:56 +00:00
Jeff Young 7b05e456cc Bug fixes for multiple symbol instances in complex hierarchies
1) use SCH_COMPONENT::GetRef(), GetValue() and GetFootprint() when
instance-specific info is needed
2) update UpdateAllScreenReferences() to handle value and footprint.
3) BACKANNO is CvPcb's handler, not back annotation's handler.  Which
means it needs GUI behaviour, not back annotation behaviour.

Fixes https://gitlab.com/kicad/code/kicad/issues/5520
2020-09-06 13:57:14 +01:00
Jeff Young 1ea08f27f8 Keep local number up-to-date so we don't have to look at libPin's.
The libPin, in particuar, may have been freed.

Fixes https://gitlab.com/kicad/code/kicad/issues/5399
2020-08-31 20:09:47 +01:00
Ian McInerney 750b186582 Return the type and shape for alternate pins
These return statements were missing from the original implementation,
so the alternate style was never being returned.
2020-08-24 01:18:46 +01:00
Jeff Young 97c34e2516 ADDED alternate pin definitions and assignments.
Fixes https://gitlab.com/kicad/code/kicad/issues/2002
2020-08-21 18:29:36 +01:00
Seth Hillbrand 275e810573 eeschema: Use recursive mutex for SCH_PIN
We need to be able to lock individual actions while keeping the code
modular.  The recursive mutex keeps this thread-local.

Fixes https://gitlab.com/kicad/code/kicad/issues/5186
2020-08-14 18:42:11 -07:00
Jeff Young 2b0b7a5153 Clear pin net-name-driving cache when changing annotation.
Also update connectivity after clear annotation, annotate or back
annotate.

Also update status bar for highlighted nets.

Fixes https://gitlab.com/kicad/code/kicad/issues/5170
2020-08-14 12:41:20 +01:00
Jeff Young dcd02539e3 Remove linked-pin processing from LIB_PIN's setters.
It belongs in the tool layer (specifically LIB_PIN_TOOL).
2020-08-03 22:21:35 +01:00
Jon Evans d8be5f9ecf Don't allow pins with NC electrical type to join other nets
Fixes https://gitlab.com/kicad/code/kicad/-/issues/1826
2020-07-06 20:27:38 -04:00