Please note that the symbol cache is not embedded in the schematic file
to allow for round robin testing with the existing file format. Once
the parser round robin testing is complete, the symbol cache will be
embedded in the schematic file.
Convert minimum sheet width and height definitions from mils to internal
units.
Add comment to sheet minimum width and height definitions to indicate
sizes are in mils.
Scope: NETLIST_ITEM, CONNECTION_TYPE, ELECTRICAL_PINTYPE,
NET_CONNECTION, NETLIST_ITEM, GRAPHIC_PINSHAPE
Note, the pin type enum had PT_ added to the front to prevent
shadowing of the INPUT symbol on msys2 (see discussion at
c17c9960d8)
This also removes vector cover types which do nothing except obfuscate
the underlying implementation.
Mainly changes SCH_SHEET_PINS and CONFIG_PARAM_ARRAY (which will soon
be replaced by Jon's new stuff).
This moves EESchema DLIST structures to rtree. These changes are more
fundamental than the pcbnew changes from 9163ac543888c01d11d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
* Split up the thirdparty code into the thirdparty folder (#3637)
* Create a new kimath static library containing all the math functions
This is part of cleaning the build system for #1906.
Add missing check for root sheet when searching sheet hierarchies for
already loaded schematics. This prevents the root sheet from being
omitted when adding new sheets using the root sheet file name.
CHANGED: Make file name tests case sensitive so that schematic sheet
file names on non-Windows systems can be uses as expected.
Warn users when attempting to use schematic file names that only vary
by case sensitivity that doing so will result in a project that is not
portable to Windows.
Fixes lp:1843415
https://bugs.launchpad.net/kicad/+bug/1843415
1) When sheet pins are on 3 or more sides there's no point in switching
the orientation to vertical.
2) Careful that we don't cause the sheet to walk when rotating and the
sheet-name or file-name is longer than the side it's on.
Fixes: lp:1841714
* https://bugs.launchpad.net/kicad/+bug/1841714
Prefix the sheet name with "Sheet: " and the sheet file name with "File: "
when plotting so that it matches the display sheet rendering.
Improve the root sheet plot file name.
Fixes lp:1832081
https://bugs.launchpad.net/kicad/+bug/1832081
Bus upgrades: core new connectivity code
Bus upgrades: eeschema integration and modifications
Bus upgrades: eeschema dialogs
Bus upgrades: netlist export
Bus upgrades: file format changes
No dangling symbol for text items with a NO-CONNECT.
DanglingStateChanged doesn't work with dangling flag aggregators
(which return true if any child is dangling).
Then again, we don't actually use any of the aggregators anyway
so I removed them.
Fixes: lp:1799589
* https://bugs.launchpad.net/kicad/+bug/1799589