Commit Graph

41 Commits

Author SHA1 Message Date
Jeff Young be15053745 Allow back-annotation of differing values and footprints.
Also fixes a couple of bugs where resolving a textVar reference
to the refDes or unit wouldn't get the correct value in a
hierarchical schematic. (Unlogged.)

Fixes https://gitlab.com/kicad/code/kicad/issues/5397
2020-09-04 15:21:56 +00:00
Jeff Young c56599ab07 Allow ERC/DRC markers to be deleted without deleting exclusions.
Fixes https://gitlab.com/kicad/code/kicad/issues/4953
2020-08-02 22:45:48 +01:00
Jeff Young 7340c97ef9 Undo for schematic-wide operations.
Editing value/footprint fields of multi-unit components.
Find/Change.
Annotation.
Back annotation.

Fixes https://gitlab.com/kicad/code/kicad/issues/2122

Fixes https://gitlab.com/kicad/code/kicad/issues/4869

Fixes https://gitlab.com/kicad/code/kicad/issues/3933

Fixes https://gitlab.com/kicad/code/kicad/issues/4871

Fixes https://gitlab.com/kicad/code/kicad/issues/3899
2020-07-13 12:32:17 +01:00
Jeff Young 3939b31027 Integration of netclasses into Eeschema.
This is mostly architecture, with the hookup of the Schematic Setup
dialog's Net Classes page.  Things like assigning to a net on the
canvas to follow.

Fixes https://gitlab.com/kicad/code/kicad/issues/2132

Fixes https://gitlab.com/kicad/code/kicad/issues/4581
2020-07-06 20:00:50 +01:00
Jeff Young f84406009b Push a couple of layers of indirection out of grid settings. 2020-06-13 11:35:56 +01:00
Jon Evans f7578eb038 Implement new native netlist QA test 2020-05-23 21:04:11 -04:00
Jon Evans 7c7b7f41da Move SCH_SCREEN project access to SCHEMATIC
SCH_SCREEN no longer needs to be a KIWAY_HOLDER
2020-05-20 22:27:48 -04:00
Jon Evans d7bd4c9b04 Move Eeschema globals to new SCHEMATIC object
Set up a new lineage for SCH_ITEMS to get back to the SCHEMATIC
they live on: Items will all be parented to the SCH_SCREEN that
they are added to, and each SCH_SCREEN will point back to the
SCHEMATIC that it is part of.  Note that this hierarchy is not
the same as the actual schematic hierarchy, which continues to
be managed through SCH_SHEETs and SCH_SHEET_PATHS.
2020-05-18 13:04:56 -04:00
Wayne Stambaugh 169f63a6c0 Eeschema: make schematic sharing truly safe across all designs.
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects.  It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic).  This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet.  This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references.  It also allows the root schematic from one project
to be uses as a sub-sheet in another project.

When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs.  This is done to ensure there
are no sheet path instance clashes between projects.  That being said,
there are no checks for this.  It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
2020-05-04 12:40:03 +00:00
Wayne Stambaugh 7183e9f97e Make the new schematic and symbol library file formats the default.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.

The new file formats are now the default in both the schematic and symbol
library editors.  Existing symbol libraries will be saved in their current
format until new features are added to library symbols.  Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted.  Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.

When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier.  The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.

The next save after loading a legacy schematic file will be converted to
the s-expression file format.  Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.

Appending schematics requires that the schematic to append has already been
converted to the new file format.  This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.

The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol.  This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed.  It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.

When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded.  Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.

Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically.  No external manipulation of this library cache should ever
occur.

ADDED: S-expression schematic and symbol library file formats.
2020-05-04 12:40:03 +00:00
Jeff Young 0370eff7ba Add sheet number processing to sheet fields.
Also fixes a bug where we were depending on the old deque stuff's
deterministic traversal, which isn't provided by the new RTree stuff.

Fixes https://gitlab.com/kicad/code/kicad/issues/2433
2020-05-03 20:56:32 +01:00
Jon Evans 2eaefb4874 Improve performance of schematic load and connectivity
Store component paths and references efficiently
Remove redundant calls to RecalculateConnections
2020-04-30 19:53:25 +00:00
Jeff Young 2b6089240a Change super/subscript syntax to ^{foo} and _{foo}. 2020-04-18 21:04:41 +01:00
Jeff Young 9c8941e040 Remove a bunch of globals. 2020-04-16 17:34:46 +01:00
Jeff Young cee973dc04 Move ERC error reporting over to the new framework.
Fixes https://gitlab.com/kicad/code/kicad/issues/1989
2020-03-16 11:06:15 +00:00
Jeff Young 490f39a671 Remove obsolete code requiring unique sheet names. 2020-02-20 22:56:11 +00:00
Jon Evans ac875e26a8 Fix handling of SCH_PINs on multi-unit parts
Fixes https://gitlab.com/kicad/code/kicad/issues/3770
2020-02-04 11:51:29 +00:00
Seth Hillbrand b8920a9f5a Eeschema: Add protections to eeschema rtree
Prevents items from being mistakenly added to the tree that should not
be tracked in the tree.
2020-01-25 09:32:05 -08:00
Seth Hillbrand 6e5e453d0d Replace EESchema DLIST
This moves EESchema DLIST structures to rtree.  These changes are more
fundamental than the pcbnew changes from 9163ac543 888c01d11 d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
2020-01-10 06:37:08 -08:00
Wayne Stambaugh d4cea0f2b7 Eeschema: fix multiple sheet file name bugs.
Add missing check for root sheet when searching sheet hierarchies for
already loaded schematics.  This prevents the root sheet from being
omitted when adding new sheets using the root sheet file name.

CHANGED: Make file name tests case sensitive so that schematic sheet
file names on non-Windows systems can be uses as expected.

Warn users when attempting to use schematic file names that only vary
by case sensitivity that doing so will result in a project that is not
portable to Windows.

Fixes lp:1843415

https://bugs.launchpad.net/kicad/+bug/1843415
2019-11-18 07:59:30 -05:00
Seth Hillbrand 83b2332f1f eeschema: Check for proper type before dereference
When bundling a selection, we need to ensure that we have correct types
before attempting to dereference.

Fixes: lp:1841919
* https://bugs.launchpad.net/kicad/+bug/1841919
2019-08-29 08:47:26 -07:00
Jeff Young b4c8657904 Fix non-visible-part or conversion items from getting selected.
Also renames lib_draw_item to lib_item to match the class.

Fixes: lp:1840170
* https://bugs.launchpad.net/kicad/+bug/1840170
2019-08-15 10:00:23 +01:00
Wayne Stambaugh 9fae30162d Eeschema: fix many append schematic bugs.
Do not add cache library from another project to old library list.  This
is wrong and can cause all kinds of symbol library linking issues.  It's
better to force the user to fix broken symbol library links than the false
security of using multiple cache libraries.

Use correct paths when appending schematic outside of the current project
path when hierarchical sheets are appended.  If the path can be relative,
give the user the option to use either relative or absolute paths.

Do not change symbol library names in schematics appended from a source
outside the current project.  This will almost ensure the symbol library
links will be broken in the source project.

When the appended schematic is from another project, attempt to check all
of the possible combinations of symbol library table importing that could
cause broken symbol library links and give the user the option of canceling
the append operation or live with the possibility that there may be broken
symbol library links.

When the append schematic is in the current project path but not part of
the schematic, check to see if there are any library nicknames that do
no exist in the project symbol library table and give the user a chance
to cancel the append process.
2019-07-19 11:39:29 -04:00
Jeff Young 6025256e07 Push KIWAY_HOLDER down a level so we can move a bunch of stuff that doesn't belong there out. 2019-06-10 23:46:00 +01:00
Jeff Young d6e9bdf07b Convert remaining legacy drawing code to print code. 2019-05-31 21:54:22 +01:00
Jeff Young 792c4328aa Cleanup. 2019-05-10 21:40:08 +01:00
Jeff Young ea0941cab3 Implement modern tools for LibEdit. 2019-05-10 16:11:57 +01:00
Jeff Young 469231ae15 Move Pin, Symbol Text and Symbol Anchor to modern toolset. 2019-05-07 20:39:46 +01:00
Jeff Young f87d371b8b Move to shared COLLECTORS for sch and lib. 2019-05-06 15:31:23 +01:00
Jeff Young 423d430b58 Replace deleteNode and deleteConnection with selectNode and selectConnection. 2019-05-05 17:14:29 +01:00
Jeff Young 902be18a04 More modern toolset context menu work.
Text/label type changes and bus entry shape changes.  And some
context menu bug fixing.
2019-05-05 17:12:59 +01:00
Jeff Young de347998d1 Implement drag in modern toolset. 2019-05-05 17:12:59 +01:00
Wayne Stambaugh 7d803437e2 Eeschema: fix broken symbol library links.
Force the symbol library links whenever the symbol library table has been
modified.  This will use the cache as a fallback when a library has been
removed that contains links in the schematic rather than display.

Fix the SCH_COMPONENT symbol resolver when falling back to the cache.  The
resolver was using the LIB_ID ':' notation which was failing.  Replacing
':' with '_' fixed this issue.  This was also an issue when generating the
symbol message panel information.

Convert wxLogDebug to wxLogTrace in symbol resolver code path.  Add new
trace type KICAD_SYM_RESOLVE.

Fixes lp:1821606

https://bugs.launchpad.net/kicad/+bug/1821606
2019-04-30 13:05:27 -04:00
Jeff Young 2aad4a5e57 Remove dead code from removal of eeschema legacy canvas. 2019-04-05 15:54:31 +01:00
Jon Evans 83c7e7fc65 New connectivity algorithm and bus upgrades
Bus upgrades: core new connectivity code

Bus upgrades: eeschema integration and modifications

Bus upgrades: eeschema dialogs

Bus upgrades: netlist export

Bus upgrades: file format changes
2019-03-31 19:53:41 -04:00
Jeff Young cb8e6c0df5 Handle GAL view refresh for breaking wires. 2018-10-09 11:08:55 +01:00
Jeff Young c5330ac0bf Implement zoom for GAL canvas. 2018-10-09 11:08:55 +01:00
Tomasz Wlostowski 90c7c60471 eeschema-gal: initial GALified version. Lots of stuff still to do! 2018-10-09 11:08:52 +01:00
jean-pierre charras 181ce46b91 Eeschema: fix incorrect references clearing for shared sheet paths.
Previously, when creating a new instance of a sheet, the full set of references
was cleared.
Moreover, if this sheet has sub-sheets, the annotation was incorrectly handled

Now only (and all) new sheet path(s) created have a reference cleared, as expected.
(new sheet paths can be more than one, if the new instance of the sheet has sub-sheets)

Fixes: lp:1789048
https://bugs.launchpad.net/kicad/+bug/1789048
2018-09-04 12:36:38 +02:00
jean-pierre charras 795a36c9fe Fix code after renaming files, and a bit of code cleanup (remove useless includes and multiple includes of the same files) 2018-01-30 09:57:25 +01:00
jean-pierre charras 87a437c26e rename files in eeschema 2018-01-30 09:57:22 +01:00
Renamed from eeschema/class_sch_screen.h (Browse further)