/*
* This program source code file is part of KiCad, a free EDA CAD application.
*
* Copyright (C) 2020-2023 KiCad Developers, see AUTHORS.txt for contributors.
*
* This program is free software: you can redistribute it and/or modify it
* under the terms of the GNU General Public License as published by the
* Free Software Foundation, either version 3 of the License, or (at your
* option) any later version.
*
* This program is distributed in the hope that it will be useful, but
* WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
* General Public License for more details.
*
* You should have received a copy of the GNU General Public License along
* with this program. If not, see .
*/
#ifndef KICAD_SCHEMATIC_H
#define KICAD_SCHEMATIC_H
#include
#include
#include
class BUS_ALIAS;
class CONNECTION_GRAPH;
class EDA_BASE_FRAME;
class ERC_SETTINGS;
class PROJECT;
class SCH_SCREEN;
class SCH_SHEET;
class SCH_SHEET_LIST;
class SCH_GLOBALLABEL;
class SCHEMATIC_IFACE
{
public:
SCHEMATIC_IFACE() {};
virtual ~SCHEMATIC_IFACE() {};
virtual CONNECTION_GRAPH* ConnectionGraph() const = 0;
virtual SCH_SHEET_LIST BuildSheetListSortedByPageNumbers() const = 0;
virtual void SetCurrentSheet( const SCH_SHEET_PATH& aPath ) = 0;
virtual SCH_SHEET_PATH& CurrentSheet() const = 0;
virtual wxString GetFileName() const = 0;
virtual PROJECT& Prj() const = 0;
};
class SCHEMATIC;
class SCHEMATIC_LISTENER
{
public:
virtual ~SCHEMATIC_LISTENER() {}
virtual void OnSchItemsAdded( SCHEMATIC& aSch, std::vector& aSchItem ) {}
virtual void OnSchItemsRemoved( SCHEMATIC& aSch, std::vector& aSchItem ) {}
virtual void OnSchItemsChanged( SCHEMATIC& aSch, std::vector& aSchItem ) {}
// This is called when the user changes to a new sheet, not when a sheet is altered.
// Sheet alteration events will call OnSchItems*
virtual void OnSchSheetChanged( SCHEMATIC& aSch ) {}
};
/**
* Holds all the data relating to one schematic.
*
* A schematic may consist of one or more sheets (and one root sheet)
* Right now, Eeschema can have only one schematic open at a time, but this could change.
* Please keep this possibility in mind when adding to this object.
*/
class SCHEMATIC : public SCHEMATIC_IFACE, public EDA_ITEM
{
public:
SCHEMATIC( PROJECT* aPrj );
virtual ~SCHEMATIC();
virtual wxString GetClass() const override
{
return wxT( "SCHEMATIC" );
}
/// Initialize this schematic to a blank one, unloading anything existing.
void Reset();
/// Return a reference to the project this schematic is part of
PROJECT& Prj() const override { return *m_project; }
void SetProject( PROJECT* aPrj );
const std::map* GetProperties() { return &m_properties; }
SCH_SHEET_LIST BuildSheetListSortedByPageNumbers() const override
{
return SCH_SHEET_LIST( m_rootSheet );
}
SCH_SHEET_LIST BuildUnorderedSheetList() const
{
SCH_SHEET_LIST sheets;
sheets.BuildSheetList( m_rootSheet, false );
return sheets;
}
SCH_ITEM* GetItem( const KIID& aID, SCH_SHEET_PATH* aPathOut = nullptr ) const
{
return BuildUnorderedSheetList().GetItem( aID, aPathOut );
}
SCH_SHEET& Root() const
{
return *m_rootSheet;
}
/**
* Initialize the schematic with a new root sheet.
*
* This is typically done by calling a file loader that returns the new root sheet
* As a side-effect, takes care of some post-load initialization.
*
* @param aRootSheet is the new root sheet for this schematic.
*/
void SetRoot( SCH_SHEET* aRootSheet );
/// A simple test if the schematic is loaded, not a complete one
bool IsValid() const
{
return m_rootSheet != nullptr;
}
/// Helper to retrieve the screen of the root sheet
SCH_SCREEN* RootScreen() const;
void GetContextualTextVars( wxArrayString* aVars ) const;
bool ResolveTextVar( const SCH_SHEET_PATH* aSheetPath, wxString* token, int aDepth ) const;
/// Helper to retrieve the filename from the root sheet screen
wxString GetFileName() const override;
SCH_SHEET_PATH& CurrentSheet() const override
{
return *m_currentSheet;
}
void SetCurrentSheet( const SCH_SHEET_PATH& aPath ) override
{
*m_currentSheet = aPath;
}
CONNECTION_GRAPH* ConnectionGraph() const override
{
return m_connectionGraph;
}
SCHEMATIC_SETTINGS& Settings() const;
ERC_SETTINGS& ErcSettings() const;
std::vector ResolveERCExclusions();
/**
* Return a pointer to a bus alias object for the given label, or null if one
* doesn't exist.
*/
std::shared_ptr GetBusAlias( const wxString& aLabel ) const;
/**
* Return the set of netname candidates for netclass assignment. The list will include both
* composite names (buses) and atomic net names. Names are fetched from available labels,
* power pins, etc.
*/
std::set GetNetClassAssignmentCandidates();
/**
* Resolves text vars that refer to other items.
* Note that the actual resolve is delegated to the symbol/sheet in question. This routine
* just does the look-up and delegation.
*/
bool ResolveCrossReference( wxString* token, int aDepth ) const;
std::map>& GetPageRefsMap() { return m_labelToPageRefsMap; }
std::map GetVirtualPageToSheetNamesMap() const;
std::map GetVirtualPageToSheetPagesMap() const;
wxString ConvertRefsToKIIDs( const wxString& aSource ) const;
wxString ConvertKIIDsToRefs( const wxString& aSource ) const;
/**
* Return the full schematic flattened hierarchical sheet list.
*/
SCH_SHEET_LIST& GetFullHierarchy() const;
/**
* Update the symbol value and footprint instance data for legacy designs.
*
* Prior to schematic file format version 20200828 and legacy file format version, only
* symbol reference field and unit were saved in the instance data. The value and footprint
* fields must be carried forward from the original symbol to prevent data loss.
*/
void SetLegacySymbolInstanceData();
/**
* @return a filename that can be used in plot and print functions for the current screen
* and sheet path. This filename is unique and must be used instead of the screen filename
* when one must create files for each sheet in the hierarchy.
* Name is <root sheet filename>-<sheet path> and has no extension.
* However if filename is too long name is <sheet filename>-<sheet number>
*/
wxString GetUniqueFilenameForCurrentSheet();
/**
* Set the m_ScreenNumber and m_NumberOfScreens members for screens.
*
* @note This must be called after deleting or adding a sheet and when entering a sheet.
*/
void SetSheetNumberAndCount();
/**
* Update the schematic's page reference map for all global labels, and refresh the labels
* so that they are redrawn with up-to-date references.
*/
void RecomputeIntersheetRefs( const std::function& aItemCallback );
/**
* Clear operating points from a .op simulation.
*/
void ClearOperatingPoints()
{
m_operatingPoints.clear();
}
/**
* Set operating points from a .op simulation. Called after the simulation completes.
*/
void SetOperatingPoint( const wxString& aSignal, double aValue )
{
m_operatingPoints[ aSignal ] = aValue;
}
wxString GetOperatingPoint( const wxString& aNetName, int aPrecision, const wxString& aRange );
/**
* Add junctions to this schematic where required. This function is needed for some plugins
* (e.g. Legacy and Cadstar) in order to retain connectivity after loading.
*/
void FixupJunctions();
/**
* Scan existing markers and record data from any that are Excluded.
*/
void RecordERCExclusions();
/**
* Update markers to match recorded exclusions.
*/
void ResolveERCExclusionsPostUpdate();
/**
* Must be used if Add() is used using a BULK_x ADD_MODE to generate a change event for
* listeners.
*/
void OnItemsAdded( std::vector& aNewItems );
/**
* Must be used if Remove() is used using a BULK_x REMOVE_MODE to generate a change event
* for listeners.
*/
void OnItemsRemoved( std::vector& aRemovedItems );
/**
* Notify the schematic and its listeners that an item on the schematic has
* been modified in some way.
*/
void OnItemsChanged( std::vector& aItems );
/**
* Notify the schematic and its listeners that the current sheet has been changed.
* This is called when the user navigates to a different sheet, not when the sheet is
* altered.
*/
void OnSchSheetChanged();
/**
* Add a listener to the schematic to receive calls whenever something on the
* schematic has been modified. The schematic does not take ownership of the
* listener object. Make sure to call RemoveListener before deleting the
* listener object. The order of listener invocations is not guaranteed.
* If the specified listener object has been added before, it will not be
* added again.
*/
void AddListener( SCHEMATIC_LISTENER* aListener );
/**
* Remove the specified listener. If it has not been added before, it
* will do nothing.
*/
void RemoveListener( SCHEMATIC_LISTENER* aListener );
/**
* Remove all listeners
*/
void RemoveAllListeners();
/**
* True if a SCHEMATIC exists, false if not
*/
static bool m_IsSchematicExists;
#if defined(DEBUG)
void Show( int nestLevel, std::ostream& os ) const override {}
#endif
private:
friend class SCH_EDIT_FRAME;
template
void InvokeListeners( Func&& aFunc, Args&&... args )
{
for( auto&& l : m_listeners )
( l->*aFunc )( std::forward( args )... );
}
PROJECT* m_project;
/// The top-level sheet in this schematic hierarchy (or potentially the only one)
SCH_SHEET* m_rootSheet;
/**
* The sheet path of the sheet currently being edited or displayed.
* Note that this was moved here from SCH_EDIT_FRAME because currently many places in the code
* want to know the current sheet. Potentially this can be moved back to the UI code once
* the only places that want to know it are UI-related
*/
SCH_SHEET_PATH* m_currentSheet;
/// Holds and calculates connectivity information of this schematic
CONNECTION_GRAPH* m_connectionGraph;
/**
* Holds a map of labels to the page sequence (virtual page number) that they appear on. It is
* used for updating global label intersheet references.
*/
std::map> m_labelToPageRefsMap;
/**
* Properties for text variable substitution (and perhaps other uses in future).
*/
std::map m_properties;
/**
* Simulation operating points for text variable substitution.
*/
std::map m_operatingPoints;
/**
* Currently installed listeners
*/
std::vector m_listeners;
};
#endif