/* * This program source code file is part of KiCad, a free EDA CAD application. * * Copyright (C) 2013 Jean-Pierre Charras, jp.charras at wanadoo.fr * Copyright (C) 2013 Wayne Stambaugh * Copyright (C) 2013 CERN (www.cern.ch) * Copyright (C) 1992-2020 KiCad Developers, see AUTHORS.txt for contributors. * * This program is free software; you can redistribute it and/or * modify it under the terms of the GNU General Public License * as published by the Free Software Foundation; either version 2 * of the License, or (at your option) any later version. * * This program is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the * GNU General Public License for more details. * * You should have received a copy of the GNU General Public License * along with this program; if not, you may find one here: * http://www.gnu.org/licenses/old-licenses/gpl-2.0.html * or you may search the http://www.gnu.org website for the version 2 license, * or you may write to the Free Software Foundation, Inc., * 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA */ #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include bool SCH_EDIT_FRAME::SaveEEFile( SCH_SCREEN* aScreen, bool aSaveUnderNewName, bool aCreateBackupFile ) { wxString msg; wxFileName schematicFileName; bool success; if( aScreen == NULL ) aScreen = GetScreen(); // If no name exists in the window yet - save as new. if( aScreen->GetFileName().IsEmpty() ) aSaveUnderNewName = true; // Construct the name of the file to be saved schematicFileName = Prj().AbsolutePath( aScreen->GetFileName() ); if( aSaveUnderNewName ) { wxString wildcards = LegacySchematicFileWildcard(); wildcards += "|" + KiCadSchematicFileWildcard(); wxFileDialog dlg( this, _( "Schematic Files" ), wxPathOnly( Prj().GetProjectFullName() ), schematicFileName.GetFullName(), wildcards, wxFD_SAVE | wxFD_OVERWRITE_PROMPT ); if( dlg.ShowModal() == wxID_CANCEL ) return false; schematicFileName = dlg.GetPath(); if( dlg.GetFilterIndex() == 0 && schematicFileName.GetExt() != LegacySchematicFileExtension ) schematicFileName.SetExt( LegacySchematicFileExtension ); else if( dlg.GetFilterIndex() == 1 && schematicFileName.GetExt() != KiCadSchematicFileExtension ) schematicFileName.SetExt( KiCadSchematicFileExtension ); } if( !IsWritable( schematicFileName ) ) return false; // Create backup if requested if( aCreateBackupFile && schematicFileName.FileExists() ) { wxFileName backupFileName = schematicFileName; // Rename the old file to a '-bak' suffixed one: backupFileName.SetExt( schematicFileName.GetExt() + GetBackupSuffix() ); if( backupFileName.FileExists() ) wxRemoveFile( backupFileName.GetFullPath() ); if( !wxRenameFile( schematicFileName.GetFullPath(), backupFileName.GetFullPath() ) ) { msg.Printf( _( "Could not save backup of file \"%s\"" ), GetChars( schematicFileName.GetFullPath() ) ); DisplayError( this, msg ); } } // Save wxLogTrace( traceAutoSave, wxT( "Saving file <" ) + schematicFileName.GetFullPath() + wxT( ">" ) ); SCH_IO_MGR::SCH_FILE_T pluginType = SCH_IO_MGR::GuessPluginTypeFromSchPath( schematicFileName.GetFullPath() ); SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( pluginType ) ); try { pi->Save( schematicFileName.GetFullPath(), aScreen, &Kiway() ); success = true; } catch( const IO_ERROR& ioe ) { msg.Printf( _( "Error saving schematic file \"%s\".\n%s" ), GetChars( schematicFileName.GetFullPath() ), GetChars( ioe.What() ) ); DisplayError( this, msg ); msg.Printf( _( "Failed to save \"%s\"" ), GetChars( schematicFileName.GetFullPath() ) ); AppendMsgPanel( wxEmptyString, msg, CYAN ); success = false; } if( success ) { // Delete auto save file. wxFileName autoSaveFileName = schematicFileName; autoSaveFileName.SetName( GetAutoSaveFilePrefix() + schematicFileName.GetName() ); if( autoSaveFileName.FileExists() ) { wxLogTrace( traceAutoSave, wxT( "Removing auto save file <" ) + autoSaveFileName.GetFullPath() + wxT( ">" ) ); wxRemoveFile( autoSaveFileName.GetFullPath() ); } // Update the screen and frame info and reset the lock file. if( aSaveUnderNewName ) { aScreen->SetFileName( schematicFileName.GetFullPath() ); LockFile( schematicFileName.GetFullPath() ); } aScreen->ClrSave(); aScreen->ClrModify(); msg.Printf( _( "File %s saved" ), GetChars( aScreen->GetFileName() ) ); SetStatusText( msg, 0 ); } else { DisplayError( this, _( "File write operation failed." ) ); } return success; } void SCH_EDIT_FRAME::Save_File( bool doSaveAs ) { if( doSaveAs ) { if( SaveEEFile( NULL, true ) ) CreateArchiveLibraryCacheFile( true ); } else { SaveEEFile( NULL ); } UpdateTitle(); } bool SCH_EDIT_FRAME::OpenProjectFiles( const std::vector& aFileSet, int aCtl ) { // implement the pseudo code from KIWAY_PLAYER.h: wxString msg; // This is for python: if( aFileSet.size() != 1 ) { msg.Printf( "Eeschema:%s() takes only a single filename.", __WXFUNCTION__ ); DisplayError( this, msg ); return false; } wxString fullFileName( aFileSet[0] ); // We insist on caller sending us an absolute path, if it does not, we say it's a bug. wxASSERT_MSG( wxFileName( fullFileName ).IsAbsolute(), wxT( "Path is not absolute!" ) ); if( !LockFile( fullFileName ) ) { msg.Printf( _( "Schematic file \"%s\" is already open." ), fullFileName ); DisplayError( this, msg ); return false; } if( !AskToSaveChanges() ) return false; wxFileName pro = fullFileName; pro.SetExt( ProjectFileExtension ); bool is_new = !wxFileName::IsFileReadable( fullFileName ); // If its a non-existent schematic and caller thinks it exists if( is_new && !( aCtl & KICTL_CREATE ) ) { // notify user that fullFileName does not exist, ask if user wants to create it. msg.Printf( _( "Schematic \"%s\" does not exist. Do you wish to create it?" ), fullFileName ); if( !IsOK( this, msg ) ) return false; } // unload current project file before loading new { SetScreen( nullptr ); delete g_RootSheet; if( g_CurrentSheet ) g_CurrentSheet->clear(); g_RootSheet = nullptr; CreateScreens(); } GetScreen()->SetFileName( fullFileName ); g_RootSheet->SetFileName( fullFileName ); SetStatusText( wxEmptyString ); ClearMsgPanel(); // PROJECT::SetProjectFullName() is an impactful function. It should only be // called under carefully considered circumstances. // The calling code should know not to ask me here to change projects unless // it knows what consequences that will have on other KIFACEs running and using // this same PROJECT. It can be very harmful if that calling code is stupid. // Don't reload the symbol libraries if we are just launching Eeschema from KiCad again. // They are already saved in the kiface project object. if( pro.GetFullPath() != Prj().GetProjectFullName() || !Prj().GetElem( PROJECT::ELEM_SCH_PART_LIBS ) ) { Prj().SetProjectFullName( pro.GetFullPath() ); // load the libraries here, not in SCH_SCREEN::Draw() which is a context // that will not tolerate DisplayError() dialog since we're already in an // event handler in there. // And when a schematic file is loaded, we need these libs to initialize // some parameters (links to PART LIB, dangling ends ...) Prj().SetElem( PROJECT::ELEM_SCH_PART_LIBS, NULL ); Prj().SchLibs(); } LoadProjectFile(); // Load the symbol library table, this will be used forever more. Prj().SetElem( PROJECT::ELEM_SYMBOL_LIB_TABLE, NULL ); Prj().SchSymbolLibTable(); SetShutdownBlockReason( _( "Schematic file changes are unsaved" ) ); if( is_new ) { // mark new, unsaved file as modified. GetScreen()->SetModify(); } else { SetScreen( nullptr ); delete g_RootSheet; // Delete the current project. g_RootSheet = NULL; // Force CreateScreens() to build new empty project on load failure. SCH_IO_MGR::SCH_FILE_T schFileType = SCH_IO_MGR::GuessPluginTypeFromSchPath( fullFileName ); SCH_PLUGIN* plugin = SCH_IO_MGR::FindPlugin( schFileType ); SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( plugin ); // This will rename the file if there is an autosave and the user want to recover CheckForAutoSaveFile( fullFileName ); try { g_RootSheet = pi->Load( fullFileName, &Kiway() ); g_CurrentSheet = new SCH_SHEET_PATH(); g_CurrentSheet->clear(); g_CurrentSheet->push_back( g_RootSheet ); if( !pi->GetError().IsEmpty() ) { DisplayErrorMessage( this, _( "The entire schematic could not be loaded. Errors " "occurred attempting to load \nhierarchical sheet " "schematics." ), pi->GetError() ); } } catch( const IO_ERROR& ioe ) { // Do not leave g_RootSheet == NULL because it is expected to be // a valid sheet. Therefore create a dummy empty root sheet and screen. CreateScreens(); m_toolManager->RunAction( ACTIONS::zoomFitScreen, true ); msg.Printf( _( "Error loading schematic file \"%s\".\n%s" ), GetChars( fullFileName ), GetChars( ioe.What() ) ); DisplayError( this, msg ); msg.Printf( _( "Failed to load \"%s\"" ), GetChars( fullFileName ) ); AppendMsgPanel( wxEmptyString, msg, CYAN ); return false; } // It's possible the schematic parser fixed errors due to bugs so warn the user // that the schematic has been fixed (modified). SCH_SHEET_LIST sheetList( g_RootSheet ); if( sheetList.IsModified() ) { DisplayInfoMessage( this, _( "An error was found when loading the schematic that has " "been automatically fixed. Please save the schematic to " "repair the broken file or it may not be usable with other " "versions of KiCad." ) ); } UpdateFileHistory( fullFileName ); SCH_SCREENS schematic; // Convert old projects over to use symbol library table. if( schematic.HasNoFullyDefinedLibIds() ) { DIALOG_SYMBOL_REMAP dlgRemap( this ); dlgRemap.ShowQuasiModal(); } else { // Double check to ensure no legacy library list entries have been // added to the projec file symbol library list. wxString paths; wxArrayString libNames; PART_LIBS::LibNamesAndPaths( &Prj(), false, &paths, &libNames ); if( !libNames.IsEmpty() ) { if( eeconfig()->m_Appearance.show_illegal_symbol_lib_dialog ) { wxRichMessageDialog invalidLibDlg( this, _( "Illegal entry found in project file symbol library list." ), _( "Project Load Warning" ), wxOK | wxCENTER | wxICON_EXCLAMATION ); invalidLibDlg.SetExtendedMessage( _( "Symbol libraries defined in the project file symbol library list " "are no longer supported and will be\nremoved. This may cause " "broken symbol library links under certain conditions." ) ); invalidLibDlg.ShowCheckBox( _( "Do not show this dialog again." ) ); invalidLibDlg.ShowModal(); eeconfig()->m_Appearance.show_illegal_symbol_lib_dialog = !invalidLibDlg.IsCheckBoxChecked(); } libNames.Clear(); paths.Clear(); PART_LIBS::LibNamesAndPaths( &Prj(), true, &paths, &libNames ); } // Check to see whether some old library parts need to be rescued // Only do this if RescueNeverShow was not set. auto cfg = dynamic_cast( Kiface().KifaceSettings() ); if( !cfg || !cfg->m_RescueNeverShow ) RescueSymbolLibTableProject( false ); } schematic.UpdateSymbolLinks( true ); // Update all symbol library links for all sheets. g_ConnectionGraph->Reset(); RecalculateConnections( GLOBAL_CLEANUP ); SetScreen( g_CurrentSheet->LastScreen() ); // Migrate conflicting bus definitions // TODO(JE) This should only run once based on schematic file version if( g_ConnectionGraph->GetBusesNeedingMigration().size() > 0 ) { DIALOG_MIGRATE_BUSES dlg( this ); dlg.ShowQuasiModal(); OnModify(); } GetScreen()->TestDanglingEnds(); // Only perform the dangling end test on root sheet. RecalculateConnections( GLOBAL_CLEANUP ); GetScreen()->ClearUndoORRedoList( GetScreen()->m_UndoList, 1 ); GetScreen()->m_Initialized = true; } GetScreen()->SetGrid( ID_POPUP_GRID_LEVEL_1000 + m_LastGridSizeId ); m_toolManager->RunAction( ACTIONS::zoomFitScreen, true ); SetSheetNumberAndCount(); // re-create junctions if needed. Eeschema optimizes wires by merging // colinear segments. If a schematic is saved without a valid // cache library or missing installed libraries, this can cause connectivity errors // unless junctions are added. FixupJunctions(); SyncView(); GetScreen()->ClearDrawingState(); UpdateTitle(); // If requested, generate a netlist and exit immediately. // NOTE: This is intended as a developer-only feature for now, and can be removed in lieu of // Python scripting once that is possible. if( m_generateNetlistAndExit ) { wxLogDebug( wxT( "Writing netlist to %s and exiting..." ), m_netlistFilename ); NETLIST_OBJECT_LIST* netlist = CreateNetlist( false, false ); WriteNetListFile( netlist, NET_TYPE_PCBNEW, m_netlistFilename, 0, nullptr ); Close( false ); } return true; } bool SCH_EDIT_FRAME::AppendSchematic() { wxString fullFileName; SCH_SCREEN* screen = GetScreen(); if( !screen ) { wxLogError( wxT( "Document not ready, cannot import" ) ); return false; } // open file chooser dialog wxString path = wxPathOnly( Prj().GetProjectFullName() ); wxFileDialog dlg( this, _( "Append Schematic" ), path, wxEmptyString, LegacySchematicFileWildcard(), wxFD_OPEN | wxFD_FILE_MUST_EXIST ); if( dlg.ShowModal() == wxID_CANCEL ) return false; fullFileName = dlg.GetPath(); if( !LoadSheetFromFile( GetCurrentSheet().Last(), &GetCurrentSheet(), fullFileName ) ) return false; SCH_SCREENS screens( GetCurrentSheet().Last() ); screens.TestDanglingEnds(); GetScreen()->SetGrid( ID_POPUP_GRID_LEVEL_1000 + m_LastGridSizeId ); m_toolManager->RunAction( ACTIONS::zoomFitScreen, true ); SetSheetNumberAndCount(); SyncView(); HardRedraw(); // Full reinit of the current screen and the display. OnModify(); return true; } void SCH_EDIT_FRAME::OnAppendProject( wxCommandEvent& event ) { if( GetScreen() && GetScreen()->IsModified() ) { wxString msg = _( "This operation cannot be undone.\n\n" "Do you want to save the current document before proceeding?" ); if( IsOK( this, msg ) ) SaveProject(); } AppendSchematic(); } void SCH_EDIT_FRAME::OnImportProject( wxCommandEvent& aEvent ) { if( !AskToSaveChanges() ) return; // Set the project location if none is set bool setProject = Prj().GetProjectFullName().IsEmpty(); wxString path = wxPathOnly( Prj().GetProjectFullName() ); wxFileDialog dlg( this, _( "Import Schematic" ), path, wxEmptyString, EagleSchematicFileWildcard(), wxFD_OPEN | wxFD_FILE_MUST_EXIST ); if( dlg.ShowModal() == wxID_CANCEL ) return; if( setProject ) { wxFileName projectFn( dlg.GetPath() ); projectFn.SetExt( ProjectFileExtension ); Prj().SetProjectFullName( projectFn.GetFullPath() ); } // For now there is only one import plugin importFile( dlg.GetPath(), SCH_IO_MGR::SCH_EAGLE ); } bool SCH_EDIT_FRAME::SaveProject() { SCH_SCREEN* screen; SCH_SCREENS screenList; bool success = true; // I want to see it in the debugger, show me the string! Can't do that with wxFileName. wxString fileName = Prj().AbsolutePath( g_RootSheet->GetFileName() ); wxFileName fn = fileName; if( !fn.IsDirWritable() ) { wxString msg = wxString::Format( _( "Directory \"%s\" is not writable." ), fn.GetPath() ); DisplayError( this, msg ); return false; } for( screen = screenList.GetFirst(); screen; screen = screenList.GetNext() ) success &= SaveEEFile( screen ); CreateArchiveLibraryCacheFile(); // Save the sheet name map to the project file wxString configFile = Prj().GetProjectFullName(); wxConfigBase* config = new wxFileConfig( wxEmptyString, wxEmptyString, configFile ); int index = 1; config->DeleteGroup( GROUP_SHEET_NAMES ); config->SetPath( GROUP_SHEET_NAMES ); SCH_SHEET_LIST sheetList( g_RootSheet ); for( SCH_SHEET_PATH& sheetPath : sheetList ) { SCH_SHEET* sheet = sheetPath.Last(); config->Write( wxString::Format( "%d", index++ ), wxString::Format( "%s:%s", sheet->m_Uuid.AsString(), sheet->GetName() ) ); } config->Flush(); delete config; UpdateTitle(); return success; } bool SCH_EDIT_FRAME::doAutoSave() { wxFileName tmpFileName = g_RootSheet->GetFileName(); wxFileName fn = tmpFileName; wxFileName tmp; SCH_SCREENS screens; bool autoSaveOk = true; tmp.AssignDir( fn.GetPath() ); if( !tmp.IsOk() ) return false; if( !IsWritable( tmp ) ) return false; for( SCH_SCREEN* screen = screens.GetFirst(); screen; screen = screens.GetNext() ) { // Only create auto save files for the schematics that have been modified. if( !screen->IsSave() ) continue; tmpFileName = fn = screen->GetFileName(); // Auto save file name is the normal file name prefixed with GetAutoSavePrefix(). fn.SetName( GetAutoSaveFilePrefix() + fn.GetName() ); screen->SetFileName( fn.GetFullPath() ); if( SaveEEFile( screen, false, NO_BACKUP_FILE ) ) screen->SetModify(); else autoSaveOk = false; screen->SetFileName( tmpFileName.GetFullPath() ); } if( autoSaveOk ) m_autoSaveState = false; return autoSaveOk; } bool SCH_EDIT_FRAME::importFile( const wxString& aFileName, int aFileType ) { wxString projectpath; wxFileName newfilename; SCH_SHEET_LIST sheetList( g_RootSheet ); switch( (SCH_IO_MGR::SCH_FILE_T) aFileType ) { case SCH_IO_MGR::SCH_EAGLE: // We insist on caller sending us an absolute path, if it does not, we say it's a bug. wxASSERT_MSG( wxFileName( aFileName ).IsAbsolute(), wxT( "Import eagle schematic caller didn't send full filename" ) ); if( !LockFile( aFileName ) ) { wxString msg = wxString::Format( _( "Schematic file \"%s\" is already open." ), aFileName ); DisplayError( this, msg ); return false; } try { delete g_RootSheet; g_RootSheet = nullptr; SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( SCH_IO_MGR::SCH_EAGLE ) ); g_RootSheet = pi->Load( aFileName, &Kiway() ); // Eagle sheets do not use a worksheet frame by default, so set it to an empty one WS_DATA_MODEL& pglayout = WS_DATA_MODEL::GetTheInstance(); pglayout.SetEmptyLayout(); BASE_SCREEN::m_PageLayoutDescrFileName = "empty.kicad_wks"; wxFileName layoutfn( Prj().GetProjectPath(), BASE_SCREEN::m_PageLayoutDescrFileName ); wxFile layoutfile; if( layoutfile.Create( layoutfn.GetFullPath() ) ) { layoutfile.Write( WS_DATA_MODEL::EmptyLayout() ); layoutfile.Close(); } projectpath = Prj().GetProjectPath(); newfilename.SetPath( projectpath ); newfilename.SetName( projectpath ); newfilename.SetExt( LegacySchematicFileExtension ); g_CurrentSheet->clear(); g_CurrentSheet->push_back( g_RootSheet ); SetScreen( g_CurrentSheet->LastScreen() ); g_RootSheet->SetFileName( newfilename.GetFullPath() ); GetScreen()->SetFileName( newfilename.GetFullPath() ); GetScreen()->SetModify(); SaveProjectSettings(); UpdateFileHistory( aFileName ); SCH_SCREENS schematic; schematic.UpdateSymbolLinks(); // Update all symbol library links for all sheets. GetScreen()->m_Initialized = true; SCH_SCREENS allScreens; for( SCH_SCREEN* screen = allScreens.GetFirst(); screen; screen = allScreens.GetNext() ) { for( auto item : screen->Items().OfType( SCH_COMPONENT_T ) ) { std::vector pts; SCH_COMPONENT* cmp = static_cast( item ); // Update footprint LIB_ID to point to the imported Eagle library auto fpField = cmp->GetField( FOOTPRINT ); if( !fpField->GetText().IsEmpty() ) { LIB_ID fpId; fpId.Parse( fpField->GetText(), LIB_ID::ID_SCH, true ); fpId.SetLibNickname( newfilename.GetName() ); fpField->SetText( fpId.Format() ); } } } // Only perform the dangling end test on root sheet. GetScreen()->TestDanglingEnds(); RecalculateConnections( GLOBAL_CLEANUP ); GetScreen()->ClearUndoORRedoList( GetScreen()->m_UndoList, 1 ); GetScreen()->SetGrid( ID_POPUP_GRID_LEVEL_1000 + m_LastGridSizeId ); m_toolManager->RunAction( ACTIONS::zoomFitScreen, true ); SetSheetNumberAndCount(); SyncView(); UpdateTitle(); } catch( const IO_ERROR& ioe ) { // Do not leave g_RootSheet == NULL because it is expected to be // a valid sheet. Therefore create a dummy empty root sheet and screen. CreateScreens(); m_toolManager->RunAction( ACTIONS::zoomFitScreen, true ); wxString msg; msg.Printf( _( "Error loading schematic \"%s\".\n%s" ), aFileName, ioe.What() ); DisplayError( this, msg ); msg.Printf( _( "Failed to load \"%s\"" ), aFileName ); AppendMsgPanel( wxEmptyString, msg, CYAN ); return false; } return true; default: return false; } } bool SCH_EDIT_FRAME::AskToSaveChanges() { SCH_SCREENS screenList; // Save any currently open and modified project files. for( SCH_SCREEN* screen = screenList.GetFirst(); screen; screen = screenList.GetNext() ) { if( screen->IsModify() ) { if( !HandleUnsavedChanges( this, _( "The current schematic has been modified. " "Save changes?" ), [&]()->bool { return SaveProject(); } ) ) { return false; } } } return true; }