/* * This program source code file is part of KiCad, a free EDA CAD application. * * Copyright (C) 2016 Jean-Pierre Charras, jp.charras at wanadoo.fr * Copyright (C) 2016 KiCad Developers, see AUTHORS.txt for contributors. * * This program is free software; you can redistribute it and/or * modify it under the terms of the GNU General Public License * as published by the Free Software Foundation; either version 2 * of the License, or (at your option) any later version. * * This program is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the * GNU General Public License for more details. * * You should have received a copy of the GNU General Public License * along with this program; if not, you may find one here: * http://www.gnu.org/licenses/old-licenses/gpl-2.0.html * or you may search the http://www.gnu.org website for the version 2 license, * or you may write to the Free Software Foundation, Inc., * 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA */ #ifndef GBR_NETLIST_METADATA_H #define GBR_NETLIST_METADATA_H /** this class handle info which can be added in a gerber P&P file as attribute * of a component * Only applicable to objects having the TA.AperFunction attribute "ComponentMain" * There are specific attributes defined attached to the component by the %TO command * %TO.CRot, The rotation angle of the component. * The rotation angle is consistent with the one for graphics objects. * Positive rotation is counter- clockwise as viewed from the top side, even if * the component is on the board side. * The base orientation of component – no rotation - on the top side is as in IPC-7351. * Components on the bottom side are of course mirrored. * The base orientation on the bottom side is the one on the top side * mirrored around the X axis. * %TO.CMfr, Manufacturer * %TO.CMPN, Manufacturer part number * %TO.Cpkg, Package, as per IPC-7351 * %TO.CVal, Value, a string. E.g. 220nF * %TO.CMnt, Mount type: (SMD|TH|Other) * %TO.CFtp, Footprint name, a string. E.g. LQFP-100_14x14mm_P0.5mm This is the footprint name coming from the CAD tool libraries. * %TO.CPgN, Package name, like the JEDEC JEP95 standard. * %TO.CPgD, Package description. * %TO.CHgt, Height, a decimal, in the unit of the file. * %TO.CLbN, Library name. * %TO.CLbD, Library description. * %TO.Sup,, SN is a field with the supppier name. * SPN is a field with the supppier part name */ class GBR_CMP_PNP_METADATA { public: enum MOUNT_TYPE { MOUNT_TYPE_UNSPECIFIED, MOUNT_TYPE_SMD, MOUNT_TYPE_TH }; double m_Orientation; // orientation in degree wxString m_Manufacturer; // Manufacturer name wxString m_MPN; // Manufacturer part number wxString m_Package; // Package, as per IPC-7351 wxString m_Footprint; // Footprint name, from library wxString m_LibraryName; // Library name, containing the footprint wxString m_LibraryDescr; // Library description wxString m_Value; // Component value MOUNT_TYPE m_MountType; // SMD|TH|Other GBR_CMP_PNP_METADATA() : m_Orientation( 0.0 ), m_MountType( MOUNT_TYPE_UNSPECIFIED ) {} void ClearData(); // Clear all strings /** * @return a string containing the formated metadata in X2 syntax. * one line by non empty data * the orientation is always generated */ wxString FormatCmpPnPMetadata(); }; /** this class handle info which can be added in a gerber file as attribute * of an object * the GBR_INFO_TYPE types can be OR'ed to add 2 (or more) attributes * There are only 3 net attributes defined attached to an object by the %TO command * %TO.P * %TO.N * %TO.C * the .P attribute can be used only for flashed pads (using the D03 command) * and only for external copper layers, if the component is on a external copper layer * for other copper layer items (pads on internal layers, tracks ... ), only .N and .C * can be used */ class GBR_NETLIST_METADATA { public: // This enum enables the different net attributes attache to the object // the values can be ORed for items which can have more than one attribute // (A flashed pad has all allowed attributes) enum GBR_NETINFO_TYPE { GBR_NETINFO_UNSPECIFIED, ///< idle command (no command) GBR_NETINFO_PAD = 1, ///< print info associated to a flashed pad (TO.P attribute) GBR_NETINFO_NET = 2, ///< print info associated to a net (TO.N attribute) GBR_NETINFO_CMP = 4 ///< print info associated to a component (TO.C attribute) }; // these members are used in the %TO object attributes command. int m_NetAttribType; ///< the type of net info ///< (used to define the gerber string to create) bool m_NotInNet; ///< true if a pad of a footprint cannot be connected ///< (for instance a mechanical NPTH, ot a not named pad) ///< in this case the pad net name is empty in gerber file wxString m_Padname; ///< for a flashed pad: the pad name ((TO.P attribute) wxString m_Cmpref; ///< the component reference parent of the data wxString m_Netname; ///< for items associated to a net: the netname wxString m_ExtraData; ///< a string to print after %TO object attributes, if not empty ///< it is printed "as this" /** If true, do not clear all attributes when a atribute has changed * Usefull when some attributes need to be persistant. * If false, attributes will be cleared if only one attribute cleared * This is a more secure way to set attributes, when all attribute changess are not safely managed */ bool m_TryKeepPreviousAttributes; GBR_NETLIST_METADATA(): m_NetAttribType( GBR_NETINFO_UNSPECIFIED ), m_NotInNet( false ), m_TryKeepPreviousAttributes( false ) { } /** Clear the extra data string printed at end of net attributes */ void ClearExtraData() { m_ExtraData.Clear(); } /** Set the extra data string printed at end of net attributes */ void SetExtraData( const wxString& aExtraData) { m_ExtraData = aExtraData; } /** * remove the net attribute specified by aName * If aName == NULL or empty, remove all attributes * @param aName is the name (.CN, .P .N or .C) of the attribute to remove */ void ClearAttribute( const wxString* aName ) { if( m_NetAttribType == GBR_NETINFO_UNSPECIFIED ) { m_Padname.clear(); m_Cmpref.clear(); m_Netname.clear(); return; } if( !aName || aName->IsEmpty() || *aName == ".CN" ) { m_NetAttribType = GBR_NETINFO_UNSPECIFIED; m_Padname.clear(); m_Cmpref.clear(); m_Netname.clear(); return; } if( *aName == ".C" ) { m_NetAttribType &= ~GBR_NETINFO_CMP; m_Cmpref.clear(); return; } if( *aName == ".N" ) { m_NetAttribType &= ~GBR_NETINFO_NET; m_Netname.clear(); return; } if( *aName == ".P" ) { m_NetAttribType &= ~GBR_NETINFO_PAD; m_Padname.clear(); return; } } }; // Flashed pads use the full attribute set: this is a helper for flashed pads #define GBR_NETINFO_ALL (GBR_NETLIST_METADATA::GBR_NETINFO_PAD\ | GBR_NETLIST_METADATA::GBR_NETINFO_NET\ | GBR_NETLIST_METADATA::GBR_NETINFO_CMP ) #endif // GBR_NETLIST_METADATA_H