/* * This program source code file is part of KiCad, a free EDA CAD application. * * Copyright (C) 2013 Jean-Pierre Charras, jp.charras at wanadoo.fr * Copyright (C) 2013 Wayne Stambaugh * Copyright (C) 2013 CERN (www.cern.ch) * Copyright (C) 1992-2018 KiCad Developers, see AUTHORS.txt for contributors. * * This program is free software; you can redistribute it and/or * modify it under the terms of the GNU General Public License * as published by the Free Software Foundation; either version 2 * of the License, or (at your option) any later version. * * This program is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the * GNU General Public License for more details. * * You should have received a copy of the GNU General Public License * along with this program; if not, you may find one here: * http://www.gnu.org/licenses/old-licenses/gpl-2.0.html * or you may search the http://www.gnu.org website for the version 2 license, * or you may write to the Free Software Foundation, Inc., * 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA */ /** * @file eeschema/files-io.cpp */ #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include bool SCH_EDIT_FRAME::SaveEEFile( SCH_SCREEN* aScreen, bool aSaveUnderNewName, bool aCreateBackupFile ) { wxString msg; wxFileName schematicFileName; bool success; if( aScreen == NULL ) aScreen = GetScreen(); // If no name exists in the window yet - save as new. if( aScreen->GetFileName().IsEmpty() ) aSaveUnderNewName = true; // Construct the name of the file to be saved schematicFileName = Prj().AbsolutePath( aScreen->GetFileName() ); if( aSaveUnderNewName ) { wxFileDialog dlg( this, _( "Schematic Files" ), wxPathOnly( Prj().GetProjectFullName() ), schematicFileName.GetFullName(), SchematicFileWildcard(), wxFD_SAVE | wxFD_OVERWRITE_PROMPT ); if( dlg.ShowModal() == wxID_CANCEL ) return false; schematicFileName = dlg.GetPath(); if( schematicFileName.GetExt() != SchematicFileExtension ) schematicFileName.SetExt( SchematicFileExtension ); } if( !IsWritable( schematicFileName ) ) return false; // Create backup if requested if( aCreateBackupFile && schematicFileName.FileExists() ) { wxFileName backupFileName = schematicFileName; // Rename the old file to a '.bak' one: backupFileName.SetExt( SchematicBackupFileExtension ); if( backupFileName.FileExists() ) wxRemoveFile( backupFileName.GetFullPath() ); if( !wxRenameFile( schematicFileName.GetFullPath(), backupFileName.GetFullPath() ) ) { msg.Printf( _( "Could not save backup of file \"%s\"" ), GetChars( schematicFileName.GetFullPath() ) ); DisplayError( this, msg ); } } // Save wxLogTrace( traceAutoSave, wxT( "Saving file <" ) + schematicFileName.GetFullPath() + wxT( ">" ) ); SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( SCH_IO_MGR::SCH_LEGACY ) ); try { pi->Save( schematicFileName.GetFullPath(), aScreen, &Kiway() ); success = true; } catch( const IO_ERROR& ioe ) { msg.Printf( _( "Error saving schematic file \"%s\".\n%s" ), GetChars( schematicFileName.GetFullPath() ), GetChars( ioe.What() ) ); DisplayError( this, msg ); msg.Printf( _( "Failed to save \"%s\"" ), GetChars( schematicFileName.GetFullPath() ) ); AppendMsgPanel( wxEmptyString, msg, CYAN ); success = false; } if( success ) { // Delete auto save file. wxFileName autoSaveFileName = schematicFileName; autoSaveFileName.SetName( AUTOSAVE_PREFIX_FILENAME + schematicFileName.GetName() ); if( autoSaveFileName.FileExists() ) { wxLogTrace( traceAutoSave, wxT( "Removing auto save file <" ) + autoSaveFileName.GetFullPath() + wxT( ">" ) ); wxRemoveFile( autoSaveFileName.GetFullPath() ); } // Update the screen and frame info. if( aSaveUnderNewName ) aScreen->SetFileName( schematicFileName.GetFullPath() ); aScreen->ClrSave(); aScreen->ClrModify(); msg.Printf( _( "File %s saved" ), GetChars( aScreen->GetFileName() ) ); SetStatusText( msg, 0 ); } else { DisplayError( this, _( "File write operation failed." ) ); } return success; } void SCH_EDIT_FRAME::Save_File( wxCommandEvent& event ) { int id = event.GetId(); switch( id ) { case ID_UPDATE_ONE_SHEET: SaveEEFile( NULL ); break; case ID_SAVE_ONE_SHEET_UNDER_NEW_NAME: if( SaveEEFile( NULL, true ) ) { CreateArchiveLibraryCacheFile( true ); } break; } UpdateTitle(); } bool SCH_EDIT_FRAME::OpenProjectFiles( const std::vector& aFileSet, int aCtl ) { // implement the pseudo code from KIWAY_PLAYER.h: // This is for python: if( aFileSet.size() != 1 ) { UTF8 msg = StrPrintf( "Eeschema:%s() takes only a single filename.", __func__ ); DisplayError( this, msg ); return false; } wxString fullFileName( aFileSet[0] ); // We insist on caller sending us an absolute path, if it does not, we say it's a bug. wxASSERT_MSG( wxFileName( fullFileName ).IsAbsolute(), wxT( "Path is not absolute!" ) ); if( !LockFile( fullFileName ) ) { wxString msg = wxString::Format( _( "Schematic file \"%s\" is already open." ), fullFileName ); DisplayError( this, msg ); return false; } if( !AskToSaveChanges() ) return false; wxFileName pro = fullFileName; pro.SetExt( ProjectFileExtension ); bool is_new = !wxFileName::IsFileReadable( fullFileName ); // If its a non-existent schematic and caller thinks it exists if( is_new && !( aCtl & KICTL_CREATE ) ) { // notify user that fullFileName does not exist, ask if user wants to create it. wxString ask = wxString::Format( _( "Schematic \"%s\" does not exist. Do you wish to create it?" ), fullFileName ); if( !IsOK( this, ask ) ) return false; } // unload current project file before loading new { delete g_RootSheet; g_RootSheet = NULL; CreateScreens(); } GetScreen()->SetFileName( fullFileName ); g_RootSheet->SetFileName( fullFileName ); SetStatusText( wxEmptyString ); ClearMsgPanel(); // PROJECT::SetProjectFullName() is an impactful function. It should only be // called under carefully considered circumstances. // The calling code should know not to ask me here to change projects unless // it knows what consequences that will have on other KIFACEs running and using // this same PROJECT. It can be very harmful if that calling code is stupid. // Don't reload the symbol libraries if we are just launching Eeschema from KiCad again. // They are already saved in the kiface project object. if( pro.GetFullPath() != Prj().GetProjectFullName() || !Prj().GetElem( PROJECT::ELEM_SCH_PART_LIBS ) ) { Prj().SetProjectFullName( pro.GetFullPath() ); // load the libraries here, not in SCH_SCREEN::Draw() which is a context // that will not tolerate DisplayError() dialog since we're already in an // event handler in there. // And when a schematic file is loaded, we need these libs to initialize // some parameters (links to PART LIB, dangling ends ...) Prj().SetElem( PROJECT::ELEM_SCH_PART_LIBS, NULL ); Prj().SchLibs(); } LoadProjectFile(); // Load the symbol library table, this will be used forever more. Prj().SetElem( PROJECT::ELEM_SYMBOL_LIB_TABLE, NULL ); Prj().SchSymbolLibTable(); if( is_new ) { // mark new, unsaved file as modified. GetScreen()->SetModify(); } else { delete g_RootSheet; // Delete the current project. g_RootSheet = NULL; // Force CreateScreens() to build new empty project on load failure. SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( SCH_IO_MGR::SCH_LEGACY ) ); try { g_RootSheet = pi->Load( fullFileName, &Kiway() ); m_CurrentSheet->clear(); m_CurrentSheet->push_back( g_RootSheet ); if( !pi->GetError().IsEmpty() ) { DisplayErrorMessage( this, _( "The entire schematic could not be loaded. Errors " "occurred attempting to load \nhierarchical sheet " "schematics." ), pi->GetError() ); } } catch( const IO_ERROR& ioe ) { // Do not leave g_RootSheet == NULL because it is expected to be // a valid sheet. Therefore create a dummy empty root sheet and screen. CreateScreens(); Zoom_Automatique( false ); wxString msg; msg.Printf( _( "Error loading schematic file \"%s\".\n%s" ), GetChars( fullFileName ), GetChars( ioe.What() ) ); DisplayError( this, msg ); msg.Printf( _( "Failed to load \"%s\"" ), GetChars( fullFileName ) ); AppendMsgPanel( wxEmptyString, msg, CYAN ); return false; } SetScreen( m_CurrentSheet->LastScreen() ); // It's possible the schematic parser fixed errors due to bugs so warn the user // that the schematic has been fixed (modified). SCH_SHEET_LIST sheetList( g_RootSheet ); if( sheetList.IsModified() ) { DisplayInfoMessage( this, _( "An error was found when loading the schematic that has " "been automatically fixed. Please save the schematic to " "repair the broken file or it may not be usable with other " "versions of KiCad." ) ); } UpdateFileHistory( fullFileName ); SCH_SCREENS schematic; // Convert old projects over to use symbol library table. if( schematic.HasNoFullyDefinedLibIds() ) { DIALOG_SYMBOL_REMAP dlgRemap( this ); dlgRemap.ShowQuasiModal(); } else { // Check to see whether some old library parts need to be rescued // Only do this if RescueNeverShow was not set. wxConfigBase *config = Kiface().KifaceSettings(); bool rescueNeverShow = false; config->Read( RescueNeverShowEntry, &rescueNeverShow, false ); if( !rescueNeverShow ) RescueSymbolLibTableProject( false ); } schematic.UpdateSymbolLinks(); // Update all symbol library links for all sheets. // Ensure the schematic is fully segmented on first display BreakSegmentsOnJunctions(); SchematicCleanUp( true ); GetScreen()->ClearUndoORRedoList( GetScreen()->m_UndoList, 1 ); GetScreen()->TestDanglingEnds(); // Only perform the dangling end test on root sheet. } GetScreen()->SetGrid( ID_POPUP_GRID_LEVEL_1000 + m_LastGridSizeId ); Zoom_Automatique( false ); SetSheetNumberAndCount(); m_canvas->Refresh( true ); GetScreen()->ClearDrawingState(); return true; } bool SCH_EDIT_FRAME::AppendSchematic() { wxString msg; wxString fullFileName; SCH_SCREEN* screen = GetScreen(); if( !screen ) { wxLogError( wxT( "Document not ready, cannot import" ) ); return false; } // open file chooser dialog wxString path = wxPathOnly( Prj().GetProjectFullName() ); wxFileDialog dlg( this, _( "Append Schematic" ), path, wxEmptyString, SchematicFileWildcard(), wxFD_OPEN | wxFD_FILE_MUST_EXIST ); if( dlg.ShowModal() == wxID_CANCEL ) return false; fullFileName = dlg.GetPath(); wxFileName fn = fullFileName; if( fn.IsRelative() ) { fn.MakeAbsolute(); fullFileName = fn.GetFullPath(); } wxString cache_name = PART_LIBS::CacheName( fullFileName ); if( !!cache_name ) { PART_LIBS* libs = Prj().SchLibs(); try { if( PART_LIB* lib = libs->AddLibrary( cache_name ) ) lib->SetCache(); } catch( const IO_ERROR& ioe ) { DisplayError( this, ioe.What() ); } } wxLogDebug( wxT( "Importing schematic " ) + fullFileName ); // Load the schematic into a temporary sheet. SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( SCH_IO_MGR::SCH_LEGACY ) ); std::unique_ptr< SCH_SHEET> newSheet( new SCH_SHEET ); newSheet->SetFileName( fullFileName ); try { pi->Load( fullFileName, &Kiway(), newSheet.get() ); if( !pi->GetError().IsEmpty() ) { DisplayErrorMessage( this, _( "The entire schematic could not be load. Errors " "occurred attempting to load hierarchical sheet " "schematics." ), pi->GetError() ); } } catch( const IO_ERROR& ioe ) { msg.Printf( _( "Error occurred loading schematic file \"%s\"." ), fullFileName ); DisplayErrorMessage( this, msg, ioe.What() ); msg.Printf( _( "Failed to load schematic \"%s\"" ), fullFileName ); AppendMsgPanel( wxEmptyString, msg, CYAN ); return false; } // Make sure any new sheet changes do not cause any recursion issues. SCH_SHEET_LIST hierarchy( g_RootSheet ); // This is the schematic sheet hierarchy. SCH_SHEET_LIST sheetHierarchy( newSheet.get() ); // This is the hierarchy of the import. wxFileName destFile = screen->GetFileName(); if( destFile.IsRelative() ) destFile.MakeAbsolute( Prj().GetProjectPath() ); if( hierarchy.TestForRecursion( sheetHierarchy, destFile.GetFullPath( wxPATH_UNIX ) ) ) { msg.Printf( _( "The sheet changes cannot be made because the destination sheet already " "has the sheet \"%s\" or one of it's subsheets as a parent somewhere in " "the schematic hierarchy." ), destFile.GetFullPath() ); DisplayError( this, msg ); return false; } wxArrayString names; // Make sure the imported schematic has been remapped to the symbol library table. SCH_SCREENS newScreens( newSheet.get() ); // All screens associated with the import. if( newScreens.HasNoFullyDefinedLibIds() ) { if( !IsOK( this, "This schematic has not been remapped to the symbol library table. " "Therefore, all of the library symbol links will be broken. Do you " "want to continue?" ) ) return false; } else { // If there are symbol libraries in the imported schematic that are not in the // symbol library table of this project, there could be a lot of broken symbol // library links. Attempt to add the missing libraries to the project symbol // library table. newScreens.GetLibNicknames( names ); wxArrayString newLibNames; for( const auto& name : names ) { if( !Prj().SchSymbolLibTable()->HasLibrary( name ) ) newLibNames.Add( name ); } wxFileName symLibTableFn( fn.GetPath(), SYMBOL_LIB_TABLE::GetSymbolLibTableFileName() ); if( !newLibNames.IsEmpty() && symLibTableFn.Exists() && symLibTableFn.IsFileReadable() ) { SYMBOL_LIB_TABLE table; try { table.Load( symLibTableFn.GetFullPath() ); } catch( const IO_ERROR& ioe ) { msg.Printf( _( "An error occurred loading the symbol library table \"%s\"." ), symLibTableFn.GetFullPath() ); DisplayErrorMessage( NULL, msg, ioe.What() ); } if( !table.IsEmpty() ) { for( const auto& libName : newLibNames ) { if( !table.HasLibrary( libName ) ) continue; // Don't expand environment variable because KIPRJMOD will not be correct // for a different project. wxString uri = table.GetFullURI( libName, false ); wxFileName newLib; if( uri.Contains( "${KIPRJMOD}" ) ) { newLib.SetPath( fn.GetPath() ); newLib.SetFullName( uri.AfterLast( '}' ) ); uri = newLib.GetFullPath(); } else if( uri.Contains( "$(KIPRJMOD)" ) ) { newLib.SetPath( fn.GetPath() ); newLib.SetFullName( uri.AfterLast( ')' ) ); uri = newLib.GetFullPath(); } else { uri = table.GetFullURI( libName ); } // Add the library from the imported project to the current project // symbol library table. const SYMBOL_LIB_TABLE_ROW* row = table.FindRow( libName ); wxCHECK2_MSG( row, continue, "Library '" + libName + "' missing from symbol library table '" + symLibTableFn.GetFullPath() + "'." ); wxString newLibName = libName; int libNameCnt = 1; // Rename the imported symbol library if it already exists. while( Prj().SchSymbolLibTable()->HasLibrary( newLibName ) ) newLibName = wxString::Format( "%s%d", libName, libNameCnt ); auto newRow = new SYMBOL_LIB_TABLE_ROW( newLibName, uri, row->GetType(), row->GetOptions(), row->GetDescr() ); Prj().SchSymbolLibTable()->InsertRow( newRow ); if( libName != newLibName ) newScreens.ChangeSymbolLibNickname( libName, newLibName ); } } } } // Check for duplicate sheet names in the current page. wxArrayString duplicateSheetNames; SCH_TYPE_COLLECTOR sheets; sheets.Collect( screen->GetDrawItems(), SCH_COLLECTOR::SheetsOnly ); for( int i = 0; i < sheets.GetCount(); ++i ) { if( newSheet->GetScreen()->GetSheet( ( ( SCH_SHEET* ) sheets[i] )->GetName() ) ) duplicateSheetNames.Add( ( ( SCH_SHEET* ) sheets[i] )->GetName() ); } if( !duplicateSheetNames.IsEmpty() ) { msg.Printf( "Duplicate sheet names exist on the current page. Do you want to " "automatically rename the duplicate sheet names?" ); if( !IsOK( this, msg ) ) return false; } SCH_SCREEN* newScreen = newSheet->GetScreen(); wxCHECK_MSG( newScreen, false, "No screen defined for imported sheet." ); for( const auto& duplicateName : duplicateSheetNames ) { SCH_SHEET* renamedSheet = newScreen->GetSheet( duplicateName ); wxCHECK2_MSG( renamedSheet, continue, "Sheet " + duplicateName + " not found in imported schematic." ); timestamp_t newtimestamp = GetNewTimeStamp(); renamedSheet->SetTimeStamp( newtimestamp ); renamedSheet->SetName( wxString::Format( "Sheet%8.8lX", (unsigned long) newtimestamp ) ); } // It is finally safe to add the imported schematic. screen->Append( newScreen ); SCH_SCREENS allScreens; allScreens.ReplaceDuplicateTimeStamps(); OnModify(); SCH_SCREENS screens( GetCurrentSheet().Last() ); screens.UpdateSymbolLinks( true ); // Clear all annotation in the imported schematic to prevent clashes with existing annotation. // Must be done after updating the symbol links as we need to know about multi-unit parts. screens.ClearAnnotation(); GetScreen()->SetGrid( ID_POPUP_GRID_LEVEL_1000 + m_LastGridSizeId ); Zoom_Automatique( false ); SetSheetNumberAndCount(); m_canvas->Refresh( true ); return true; } void SCH_EDIT_FRAME::OnAppendProject( wxCommandEvent& event ) { if( GetScreen() && GetScreen()->IsModified() ) { wxString msg = _( "This operation cannot be undone.\n\n" "Do you want to save the current document before proceeding?" ); if( IsOK( this, msg ) ) SaveProject(); } AppendSchematic(); } void SCH_EDIT_FRAME::OnImportProject( wxCommandEvent& aEvent ) { if( !AskToSaveChanges() ) return; // Set the project location if none is set bool setProject = Prj().GetProjectFullName().IsEmpty(); wxString path = wxPathOnly( Prj().GetProjectFullName() ); wxFileDialog dlg( this, _( "Import Schematic" ), path, wxEmptyString, EagleSchematicFileWildcard(), wxFD_OPEN | wxFD_FILE_MUST_EXIST ); if( dlg.ShowModal() == wxID_CANCEL ) return; if( setProject ) { wxFileName projectFn( dlg.GetPath() ); projectFn.SetExt( ProjectFileExtension ); Prj().SetProjectFullName( projectFn.GetFullPath() ); } // For now there is only one import plugin importFile( dlg.GetPath(), SCH_IO_MGR::SCH_EAGLE ); } void SCH_EDIT_FRAME::OnSaveProject( wxCommandEvent& aEvent ) { SaveProject(); } bool SCH_EDIT_FRAME::SaveProject() { SCH_SCREEN* screen; SCH_SCREENS screenList; bool success = true; // I want to see it in the debugger, show me the string! Can't do that with wxFileName. wxString fileName = Prj().AbsolutePath( g_RootSheet->GetFileName() ); wxFileName fn = fileName; if( !fn.IsDirWritable() ) { wxString msg = wxString::Format( _( "Directory \"%s\" is not writable." ), fn.GetPath() ); DisplayError( this, msg ); return false; } for( screen = screenList.GetFirst(); screen; screen = screenList.GetNext() ) success &= SaveEEFile( screen ); CreateArchiveLibraryCacheFile(); UpdateTitle(); return success; } bool SCH_EDIT_FRAME::doAutoSave() { wxFileName tmpFileName = g_RootSheet->GetFileName(); wxFileName fn = tmpFileName; wxFileName tmp; SCH_SCREENS screens; bool autoSaveOk = true; tmp.AssignDir( fn.GetPath() ); if( !tmp.IsOk() ) return false; if( !IsWritable( tmp ) ) return false; for( SCH_SCREEN* screen = screens.GetFirst(); screen; screen = screens.GetNext() ) { // Only create auto save files for the schematics that have been modified. if( !screen->IsSave() ) continue; tmpFileName = fn = screen->GetFileName(); // Auto save file name is the normal file name prefixed with AUTOSAVE_PREFIX_FILENAME. fn.SetName( AUTOSAVE_PREFIX_FILENAME + fn.GetName() ); screen->SetFileName( fn.GetFullPath() ); if( SaveEEFile( screen, false, NO_BACKUP_FILE ) ) screen->SetModify(); else autoSaveOk = false; screen->SetFileName( tmpFileName.GetFullPath() ); } if( autoSaveOk ) m_autoSaveState = false; return autoSaveOk; } bool SCH_EDIT_FRAME::importFile( const wxString& aFileName, int aFileType ) { wxString projectpath; wxFileName newfilename; SCH_SHEET_LIST sheetList( g_RootSheet ); switch( (SCH_IO_MGR::SCH_FILE_T) aFileType ) { case SCH_IO_MGR::SCH_EAGLE: // We insist on caller sending us an absolute path, if it does not, we say it's a bug. wxASSERT_MSG( wxFileName( aFileName ).IsAbsolute(), wxT( "Import eagle schematic caller didn't send full filename" ) ); if( !LockFile( aFileName ) ) { wxString msg = wxString::Format( _( "Schematic file \"%s\" is already open." ), aFileName ); DisplayError( this, msg ); return false; } try { delete g_RootSheet; g_RootSheet = nullptr; SCH_PLUGIN::SCH_PLUGIN_RELEASER pi( SCH_IO_MGR::FindPlugin( SCH_IO_MGR::SCH_EAGLE ) ); g_RootSheet = pi->Load( aFileName, &Kiway() ); // Eagle sheets do not use a worksheet frame by default, so set it to an empty one WORKSHEET_LAYOUT& pglayout = WORKSHEET_LAYOUT::GetTheInstance(); pglayout.SetEmptyLayout(); BASE_SCREEN::m_PageLayoutDescrFileName = "empty.kicad_wks"; wxFileName layoutfn( Kiway().Prj().GetProjectPath(), BASE_SCREEN::m_PageLayoutDescrFileName ); wxFile layoutfile; if( layoutfile.Create( layoutfn.GetFullPath() ) ) { layoutfile.Write( WORKSHEET_LAYOUT::EmptyLayout() ); layoutfile.Close(); } projectpath = Kiway().Prj().GetProjectPath(); newfilename.SetPath( Prj().GetProjectPath() ); newfilename.SetName( Prj().GetProjectName() ); newfilename.SetExt( SchematicFileExtension ); m_CurrentSheet->clear(); m_CurrentSheet->push_back( g_RootSheet ); SetScreen( m_CurrentSheet->LastScreen() ); g_RootSheet->SetFileName( newfilename.GetFullPath() ); GetScreen()->SetFileName( newfilename.GetFullPath() ); GetScreen()->SetModify(); SaveProjectSettings( false ); UpdateFileHistory( aFileName ); SCH_SCREENS schematic; schematic.UpdateSymbolLinks(); // Update all symbol library links for all sheets. // Ensure the schematic is fully segmented on first display BreakSegmentsOnJunctions(); SchematicCleanUp( true ); SCH_TYPE_COLLECTOR components; SCH_SCREENS allScreens; for( SCH_SCREEN* screen = allScreens.GetFirst(); screen; screen = allScreens.GetNext() ) { components.Collect( screen->GetDrawItems(), SCH_COLLECTOR::ComponentsOnly ); for( int cmpIdx = 0; cmpIdx < components.GetCount(); ++cmpIdx ) { std::vector pts; SCH_COMPONENT* cmp = static_cast( components[cmpIdx] ); // Update footprint LIB_ID to point to the imported Eagle library auto fpField = cmp->GetField( FOOTPRINT ); if( !fpField->GetText().IsEmpty() ) { LIB_ID fpId; fpId.Parse( fpField->GetText(), LIB_ID::ID_SCH, true ); fpId.SetLibNickname( newfilename.GetName() ); fpField->SetText( fpId.Format() ); } // Add junction dots where necessary cmp->GetConnectionPoints( pts ); for( auto i = pts.begin(); i != pts.end(); ++i ) { if( GetScreen()->IsJunctionNeeded( *i, true ) ) AddJunction( *i, true ); } } } GetScreen()->ClearUndoORRedoList( GetScreen()->m_UndoList, 1 ); // Only perform the dangling end test on root sheet. GetScreen()->TestDanglingEnds(); GetScreen()->SetGrid( ID_POPUP_GRID_LEVEL_1000 + m_LastGridSizeId ); Zoom_Automatique( false ); SetSheetNumberAndCount(); m_canvas->Refresh( true ); UpdateTitle(); } catch( const IO_ERROR& ioe ) { // Do not leave g_RootSheet == NULL because it is expected to be // a valid sheet. Therefore create a dummy empty root sheet and screen. CreateScreens(); Zoom_Automatique( false ); wxString msg; msg.Printf( _( "Error loading schematic \"%s\".\n%s" ), aFileName, ioe.What() ); DisplayError( this, msg ); msg.Printf( _( "Failed to load \"%s\"" ), aFileName ); AppendMsgPanel( wxEmptyString, msg, CYAN ); return false; } return true; default: return false; } } bool SCH_EDIT_FRAME::AskToSaveChanges() { SCH_SCREENS screenList; // Save any currently open and modified project files. for( SCH_SCREEN* screen = screenList.GetFirst(); screen; screen = screenList.GetNext() ) { if( screen->IsModify() ) { wxString msg = _( "The current schematic has been modified. Save changes?" ); switch( UnsavedChangesDialog( this, msg ) ) { default: case wxID_CANCEL: return false; case wxID_NO: return true; case wxID_YES: return SaveProject(); } } } return true; }