/* * This program source code file is part of KiCad, a free EDA CAD application. * * Copyright (C) 2015 Jean-Pierre Charras, jp.charras wanadoo.fr * Copyright (C) 2008 Wayne Stambaugh * Copyright (C) 2004-2020 KiCad Developers, see AUTHORS.txt for contributors. * * This program is free software; you can redistribute it and/or * modify it under the terms of the GNU General Public License * as published by the Free Software Foundation; either version 2 * of the License, or (at your option) any later version. * * This program is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the * GNU General Public License for more details. * * You should have received a copy of the GNU General Public License * along with this program; if not, you may find one here: * http://www.gnu.org/licenses/old-licenses/gpl-2.0.html * or you may search the http://www.gnu.org website for the version 2 license, * or you may write to the Free Software Foundation, Inc., * 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA */ #ifndef SCH_EDIT_FRAME_H #define SCH_EDIT_FRAME_H #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include // enum PINSHEETLABEL_SHAPE #include #include class STATUS_TEXT_POPUP; class SCH_ITEM; class EDA_ITEM; class SCH_LINE; class SCH_TEXT; class SCH_BITMAP; class SCH_SHEET; class SCH_SHEET_PATH; class SCH_SHEET_PIN; class SCH_COMPONENT; class SCH_FIELD; class SCH_JUNCTION; class SCHEMATIC; class DIALOG_SCH_FIND; class wxFindReplaceData; class RESCUER; class HIERARCHY_NAVIG_DLG; // @todo Move this to transform alone with all of the transform manipulation code. /// enum used in RotationMiroir() enum COMPONENT_ORIENTATION_T { CMP_NORMAL, // Normal orientation, no rotation or mirror CMP_ROTATE_CLOCKWISE, // Rotate -90 CMP_ROTATE_COUNTERCLOCKWISE, // Rotate +90 CMP_ORIENT_0, // No rotation and no mirror id CMP_NORMAL CMP_ORIENT_90, // Rotate 90, no mirror CMP_ORIENT_180, // Rotate 180, no mirror CMP_ORIENT_270, // Rotate -90, no mirror CMP_MIRROR_X = 0x100, // Mirror around X axis CMP_MIRROR_Y = 0x200 // Mirror around Y axis }; /** Schematic annotation order options. */ enum ANNOTATE_ORDER_T { SORT_BY_X_POSITION, ///< Annotate by X position from left to right. SORT_BY_Y_POSITION, ///< Annotate by Y position from top to bottom. UNSORTED, ///< Annotate by position of component in the schematic sheet ///< object list. }; /** Schematic annotation type options. */ enum ANNOTATE_OPTION_T { INCREMENTAL_BY_REF, ///< Annotate incrementally using the first free reference number. SHEET_NUMBER_X_100, ///< Annotate using the first free reference number starting at ///< the sheet number * 100. SHEET_NUMBER_X_1000, ///< Annotate using the first free reference number starting at ///< the sheet number * 1000. }; /// Schematic search type used by the socket link with Pcbnew enum SCH_SEARCH_T { HIGHLIGHT_PIN, HIGHLIGHT_COMPONENT }; enum SCH_CLEANUP_FLAGS { NO_CLEANUP, LOCAL_CLEANUP, GLOBAL_CLEANUP }; /** * Schematic editor (Eeschema) main window. */ class SCH_EDIT_FRAME : public SCH_BASE_FRAME { // The schematic editor control class should be able to access some internal // functions of the editor frame. friend class SCH_EDITOR_CONTROL; private: SCHEMATIC* m_schematic; ///< The currently loaded schematic const SCH_CONNECTION* m_highlightedConn; ///< The highlighted net or bus, or nullptr std::vector m_projectFileParams; std::vector m_configSettings; wxPageSetupDialogData m_pageSetupData; SCH_ITEM* m_item_to_repeat; ///< Last item to insert by the repeat command. wxString m_netListerCommand; ///< Command line to call a custom net list ///< generator. int m_exec_flags; ///< Flags of the wxExecute() function ///< to call a custom net list generator. DIALOG_SCH_FIND* m_findReplaceDialog; wxString m_plotDirectoryName; wxString m_netListFormat; /// Use netcodes (net number) as net names when generating spice net lists. bool m_spiceAjustPassiveValues; /* these are PROJECT specific, not schematic editor specific wxString m_userLibraryPath; wxArrayString m_componentLibFiles; */ static PINSHEETLABEL_SHAPE m_lastSheetPinType; ///< Last sheet pin type. protected: /** * Save the schematic files that have been modified and not yet saved. * * @return true if the auto save was successful otherwise false. */ bool doAutoSave() override; /** * Returns true if the schematic has been modified. */ bool isAutoSaveRequired() const override; /** * Send the kicad netlist over to CVPCB. */ void sendNetlistToCvpcb(); public: SCH_EDIT_FRAME( KIWAY* aKiway, wxWindow* aParent ); ~SCH_EDIT_FRAME() override; SCH_SCREEN* GetScreen() const override; SCHEMATIC& Schematic() const; void OnCloseWindow( wxCloseEvent& Event ); /** * Allow edit frame to show/hide hidden pins. */ bool GetShowAllPins() const override; const wxString& GetNetListFormatName() const { return m_netListFormat; } void SetNetListFormatName( const wxString& aFormat ) { m_netListFormat = aFormat; } bool GetSpiceAjustPassiveValues() const { return m_spiceAjustPassiveValues; } void SetSpiceAdjustPassiveValues( bool aEnable ) { m_spiceAjustPassiveValues = aEnable; } /// accessor to the destination directory to use when generating plot files. const wxString& GetPlotDirectoryName() const { return m_plotDirectoryName; } void SetPlotDirectoryName( const wxString& aDirName ) { m_plotDirectoryName = aDirName; } void AddFormattingParameters( std::vector& params ); /** * Return the project file parameter list for Eeschema. * * Populate the project file parameter array specific to Eeschema if it hasn't * already been populated and return a reference to the array to the caller. */ std::vector& GetProjectFileParameters(); /** * Save changes to the project settings to the project (.pro) file. */ void SaveProjectSettings() override; /** * Loads the KiCad project file (*.pro) settings specific to Eeschema. * * @return True if the project file was loaded correctly. */ bool LoadProjectFile(); void DoShowSchematicSetupDialog( const wxString& aInitialPage = wxEmptyString, const wxString& aInitialParentPage = wxEmptyString ); /** * Insert or append a wanted symbol field name into the field names template. * * Should be used for any symbol property editor. If the name already exists, it * overwrites the same name. * * @param aFieldName is a full description of the wanted field, and it must not match * any of the default field names. * @param aGlobal indicates whether to add to the global or project table */ void AddTemplateFieldName( const TEMPLATE_FIELDNAME& aFieldName, bool aGlobal ) { m_templateFieldNames.AddTemplateFieldName( aFieldName, aGlobal ); } /** * Remove all global or project fieldname templates. */ void DeleteAllTemplateFieldNames( bool aGlobal ) { m_templateFieldNames.DeleteAllFieldNameTemplates( aGlobal ); } void LoadSettings( APP_SETTINGS_BASE* aCfg ) override; void SaveSettings( APP_SETTINGS_BASE* aCfg ) override; void CreateScreens(); void ReCreateHToolbar() override; void ReCreateVToolbar() override; void ReCreateOptToolbar() override; void ReCreateMenuBar() override; /** * Get if the current schematic has been modified but not saved. * * @return true if the any changes have not been saved */ bool IsContentModified() override; /** * Must be called after a schematic change in order to set the "modify" flag of the * current screen and update the date in frame reference. */ void OnModify() override; /** * Return a human-readable description of the current screen. */ wxString GetScreenDesc() const override; /** * Execute a remote command send by Pcbnew via a socket, * port KICAD_SCH_PORT_SERVICE_NUMBER (currently 4243) * this is a virtual function called by EDA_DRAW_FRAME::OnSockRequest(). * @param cmdline = received command from socket */ void ExecuteRemoteCommand( const char* cmdline ) override; void KiwayMailIn( KIWAY_EXPRESS& aEvent ) override; /** * Add an item to the schematic and adds the changes to the undo/redo container. * @param aUndoAppend True if the action should be appended to the current undo record. */ void AddItemToScreenAndUndoList( SCH_ITEM* aItem, bool aUndoAppend = false ); /** * Run the Find or Find & Replace dialog. */ void ShowFindReplaceDialog( bool aReplace ); /** * Run the Hierarchy Navigator dialog. * @param aForceUpdate: When true, creates a new dialog. And if a dialog * already exist, it destroys it first. */ void UpdateHierarchyNavigator( bool aForceUpdate = false ); /** * @return a reference to the Hierarchy Navigator dialog if exists, or nullptr. */ HIERARCHY_NAVIG_DLG* FindHierarchyNavigator(); void ShowFindReplaceStatus( const wxString& aMsg, int aStatusTime ); void ClearFindReplaceStatus(); /** * Get the find criteria (as set by the dialog). */ wxFindReplaceData* GetFindReplaceData(); /** * Notification that the Find dialog has closed. */ void OnFindDialogClose(); /** * Breaks a single segment into two at the specified point. * * NOTE: always appends to the existing undo state. * * @param aSegment Line segment to break * @param aPoint Point at which to break the segment * @param aNewSegment Pointer to the newly created segment (if given and created) * @param aScreen is the screen to examine, or nullptr to examine the current screen * @return True if any wires or buses were broken. */ bool BreakSegment( SCH_LINE* aSegment, const wxPoint& aPoint, SCH_LINE** aNewSegment = NULL, SCH_SCREEN* aScreen = nullptr ); /** * Checks every wire and bus for a intersection at \a aPoint and break into two segments * at \a aPoint if an intersection is found. * * NOTE: always appends to the existing undo state. * * @param aPoint Test this point for an intersection. * @param aScreen is the screen to examine, or nullptr to examine the current screen * @return True if any wires or buses were broken. */ bool BreakSegments( const wxPoint& aPoint, SCH_SCREEN* aScreen = nullptr ); /** * Tests all junctions and bus entries in the schematic for intersections with wires and * buses and breaks any intersections into multiple segments. * * NOTE: always appends to the existing undo state. * * @param aScreen is the screen to examine, or nullptr to examine the current screen * @return True if any wires or buses were broken. */ bool BreakSegmentsOnJunctions( SCH_SCREEN* aScreen = nullptr ); /** * Test all of the connectable objects in the schematic for unused connection points. * @return True if any connection state changes were made. */ bool TestDanglingEnds(); /** * Send a message to Pcbnew via a socket connection. * * Commands are: * - $PART: reference put cursor on footprint anchor * - $PIN: number $PART: reference put cursor on the footprint pad * - $SHEET: time_stamp select all footprints of components is the schematic sheet path * * @param aObjectToSync = item to be located on board * (footprint, pad, text or schematic sheet) * @param aPart = component if objectToSync is a sub item of a symbol (like a pin) */ void SendMessageToPCBNEW( EDA_ITEM* aObjectToSync, SCH_COMPONENT* aPart ); /** * Sends a net name to pcbnew for highlighting * * @param aNetName is the name of a net, or empty string to clear highlight */ void SendCrossProbeNetName( const wxString& aNetName ); /** * Sends a connection (net or bus) to pcbnew for highlighting * @param aConnection is the connection to highlight */ void SetCrossProbeConnection( const SCH_CONNECTION* aConnection ); /** * Tells PcbNew to clear the existing highlighted net, if one exists */ void SendCrossProbeClearHighlight(); const SCH_CONNECTION* GetHighlightedConnection() const { return m_highlightedConn; } void SetHighlightedConnection( const SCH_CONNECTION* aConnection ) { m_highlightedConn = aConnection; } /** * Create a flat list which stores all connected objects. * TODO(JE) Remove this once ERC is moved off of it * * @param updateStatusText decides if window StatusText should be modified. * @return NETLIST_OBJECT_LIST* - caller owns the object. */ NETLIST_OBJECT_LIST* BuildNetListBase( bool updateStatusText = true ); /** * Checks if we are ready to write a netlist file for the current schematic * * - Test for some issues (missing or duplicate references and sheet names) * * @param aSilent is true if annotation error dialog should be skipped * @param aSilentAnnotate is true if components should be reannotated silently * @returns true if all is well (i.e. you can call WriteNetListFile next) */ bool ReadyToNetlist( bool aSilent = false, bool aSilentAnnotate = false ); /** * Create a netlist file. * * @param aFormat = netlist format (NET_TYPE_PCBNEW ...) * @param aFullFileName = full netlist file name * @param aNetlistOptions = netlist options using OR'ed bits. *

* For SPICE netlist only: * if NET_USE_NETNAMES is set, use net names from labels in schematic * else use net numbers (net codes) * if NET_USE_X_PREFIX is set : change "U" and "IC" reference prefix to "X" *

* @param aReporter = a REPORTER to report error messages, * mainly if a command line must be run (can be NULL * @return true if success. */ bool WriteNetListFile( int aFormat, const wxString& aFullFileName, unsigned aNetlistOptions, REPORTER* aReporter = NULL ); /** * Clear the current component annotation. * * @param aCurrentSheetOnly Clear only the annotation for the current sheet if true. * Otherwise clear the entire schematic annotation. */ void DeleteAnnotation( bool aCurrentSheetOnly ); /** * Annotate the components in the schematic that are not currently annotated. * * @param aAnnotateSchematic Annotate the entire schematic if true. Otherwise annotate * the current sheet only. * @param aSortOption Define the annotation order. See #ANNOTATE_ORDER_T. * @param aAlgoOption Define the annotation style. See #ANNOTATE_OPTION_T. * @param aStartNumber The start number for non-sheet-based annotation styles. * @param aResetAnnotation Clear any previous annotation if true. Otherwise, keep the * existing component annotation. * @param aRepairTimestamps Test for and repair any duplicate time stamps if true. * Otherwise, keep the existing time stamps. This option * could change previous annotation because time stamps are * used to handle annotation in complex hierarchies. * @param aLockUnits When both aLockUnits and aResetAnnotation are true, all unit * associations should be kept when reannotating. That is, if * two components were R8A and R8B, they may become R3A and R3B, * but not R3A and R3C or R3C and R4D. * When aResetAnnotation is true but aLockUnits is false, the * usual behavior of annotating each part individually is * performed. * When aResetAnnotation is false, this option has no effect. * @param aReporter A sink for error messages. Use NULL_REPORTER if you don't need errors. * * When the sheet number is used in annotation, each sheet annotation starts from sheet * number * 100. In other words the first sheet uses 100 to 199, the second sheet uses * 200 to 299, and so on. */ void AnnotateComponents( bool aAnnotateSchematic, ANNOTATE_ORDER_T aSortOption, ANNOTATE_OPTION_T aAlgoOption, int aStartNumber, bool aResetAnnotation, bool aRepairTimestamps, bool aLockUnits, REPORTER& aReporter ); /** * Check for annotation errors. * * The following list of items are checked: * - Components that are not annotated. * - Duplicate component references. * - Multiple part per package components where the part number is greater number of parts * in the package. * - Multiple part per package components where the reference designator is different * between parts. * * @return Number of annotation errors found. * @param aReporter A sink for error messages. Use NULL_REPORTER if you don't need errors. * @param aOneSheetOnly Check the current sheet only if true. Otherwise check * the entire schematic. */ int CheckAnnotate( REPORTER& aReporter, bool aOneSheetOnly ); /** * Run a modal version of the Annotate dialog for a specific purpose. * @param aMessage A user message indicating the purpose. * @return the result of ShowModal() */ int ModalAnnotate( const wxString& aMessage ); // Functions used for hierarchy handling SCH_SHEET_PATH& GetCurrentSheet() const; void SetCurrentSheet( const SCH_SHEET_PATH& aSheet ); /** * Rebuild the GAL and redraw the screen. Call when something went wrong. */ void HardRedraw() override; /** * Draw the current sheet on the display. */ void DisplayCurrentSheet(); /** * Use the wxWidgets print code to draw an image of the current sheet onto * the clipboard. */ void DrawCurrentSheetToClipboard(); /** * Called when modifying the page settings. * In derived classes it can be used to modify parameters like draw area size, * and any other local parameter related to the page settings. */ void OnPageSettingsChange() override; /** * @return a filename that can be used in plot and print functions * for the current screen and sheet path. * This filename is unique and must be used instead of the screen filename * (or screen filename) when one must creates file for each sheet in the * hierarchy. because in complex hierarchies a sheet and a SCH_SCREEN is * used more than once * Name is <root sheet filename>-<sheet path> and has no extension. * However if filename is too long name is <sheet filename>-<sheet number> */ wxString GetUniqueFilenameForCurrentSheet(); /** * Set the m_ScreenNumber and m_NumberOfScreens members for screens. * * @note This must be called after deleting or adding a sheet and when entering a sheet. */ void SetSheetNumberAndCount(); wxPageSetupDialogData& GetPageSetupData() { return m_pageSetupData; } void NewProject(); void LoadProject(); void Save_File( bool doSaveAs = false ); bool SaveProject(); bool OpenProjectFiles( const std::vector& aFileSet, int aCtl = 0 ) override; wxString GetCurrentFileName() const override; /** * Import a KiCad schematic into the current sheet. * * @return True if the schematic was imported properly. */ bool AppendSchematic(); /** * Save \a aSheet to a schematic file. * * @param aSheet A pointer to the #SCH_SHEET object to save. A NULL pointer saves * the current screen only. * @param aSaveUnderNewName Controls how the file is to be saved;: using previous name * or under a new name . * @param aCreateBackupFile Creates a back of the file associated with \a aScreen * if true. * Helper definitions #CREATE_BACKUP_FILE and * #NO_BACKUP_FILE are defined for improved code readability. * @return True if the file has been saved. */ bool SaveEEFile( SCH_SHEET* aSheet, bool aSaveUnderNewName = false, bool aCreateBackupFile = CREATE_BACKUP_FILE ); /** * Checks if any of the screens has unsaved changes and asks the user whether to save or * drop them. * * @return True if user decided to save or drop changes, false if the operation should be * canceled. */ bool AskToSaveChanges(); SCH_JUNCTION* AddJunction( const wxPoint& aPos, bool aAppendToUndo = false, bool aFinal = true ); /** * Performs routine schematic cleaning including breaking wire and buses and deleting * identical objects superimposed on top of each other. * * NOTE: always appends to the existing undo state. * * @param aScreen is the screen to examine, or nullptr to examine the current screen * @return True if any schematic clean up was performed. */ bool SchematicCleanUp( SCH_SCREEN* aScreen = nullptr ); /** * If any single wire passes through _both points_, remove the portion between the two points, * potentially splitting the wire into two. * * NOTE: always appends to the existing undo state. * * @param aStart The starting point for trimmming * @param aEnd The ending point for trimming * @return True if any wires were changed by this operation */ bool TrimWire( const wxPoint& aStart, const wxPoint& aEnd ); /** * Collects a unique list of all possible connection points in the schematic. * * @param aConnections vector of connections */ void GetSchematicConnections( std::vector< wxPoint >& aConnections ); void OnOpenPcbnew( wxCommandEvent& event ); void OnOpenCvpcb( wxCommandEvent& event ); void OnUpdatePCB( wxCommandEvent& event ); void OnAnnotate( wxCommandEvent& event ); private: // Sets up the tool framework void setupTools(); void OnExit( wxCommandEvent& event ); void OnLoadFile( wxCommandEvent& event ); void OnAppendProject( wxCommandEvent& event ); void OnImportProject( wxCommandEvent& event ); void OnClearFileHistory( wxCommandEvent& aEvent ); /** * Set the main window title bar text. * * If file name defined by SCH_SCREEN::m_FileName is not set, the title is set to the * application name appended with no file. * Otherwise, the title is set to the hierarchical sheet path and the full file name, and * read only is appended to the title if the user does not have write access to the file. */ void UpdateTitle(); /** * Verify that the symbol library links \a aSheet and all of it's child sheets have * been remapped to the symbol library table. * * @param aSheet is the #SCH_SHEET object to test. * * @return true if \a aSheet and it's child sheets have not been remapped. */ bool checkForNoFullyDefinedLibIds( SCH_SHEET* aSheet ); /** * Load the given filename but sets the path to the current project path. * * @param full filepath of file to be imported. * @param aFileType SCH_FILE_T value for file type */ bool importFile( const wxString& aFileName, int aFileType ); /** * Fills a map of uuid -> reference from the currently loaded schematic * @param aMap is a map to fill */ void mapExistingAnnotation( std::map& aMap ); public: /** * Verify that \a aSheet will not cause a recursion error in \a aHierarchy. * * @param aSheet is the #SCH_SHEET object to test. * @param aHierarchy is the #SCH_SHEET_PATH where \a aSheet is going to reside. * * @return true if \a aSheet will cause a resursion error in \a aHierarchy. */ bool CheckSheetForRecursion( SCH_SHEET* aSheet, SCH_SHEET_PATH* aHierarchy ); /** * Check \a aSchematicFileName for a potential file name case sensitivity clashes. * * On platforms where file names are case sensitive, it is possible to schematic sheet * file names that would cause issues on platforms where file name are case insensitive. * File names foo.sch and Foo.sch are unique files on Linux and MacOS but on Windows * this would result in a broken schematic. * * @param aSchematicFileName is the absolute path and file name of the file to test. * @return true if the user accepts the potential file name clase risk. */ bool AllowCaseSensitiveFileNameClashes( const wxString& aSchematicFileName ); /** * Change a text type to another one. * * The new text, label, hierarchical label, or global label is created from the old text * and the old text object is deleted. * * A tricky case is when the 'old" text is being edited (i.e. moving) because we must * create a new text, and prepare the undo/redo command data for this change and the * current move/edit command */ void ConvertTextType( SCH_TEXT* aText, KICAD_T aNewType ); /** * Edit an existing sheet or add a new sheet to the schematic. * * When \a aSheet is a new sheet: * - and the file name already exists in the schematic hierarchy, the screen associated * with the sheet found in the hierarchy is associated with \a aSheet. * - and the file name already exists on the system, then \a aSheet is loaded with the * existing file. * - and the file name does not exist in the schematic hierarchy or on the file system, * then a new screen is created and associated with \a aSheet. * * When \a aSheet is an existing sheet: * - and the file name already exists in the schematic hierarchy, the current associated * screen is replace by the one found in the hierarchy. * - and the file name already exists on the system, the current associated screen file * name is changed and the file is loaded. * - and the file name does not exist in the schematic hierarchy or on the file system, * the current associated screen file name is changed and saved to disk. * * Note: the screen is not refresh. The caller is responsible to do that * * @param aSheet is the sheet to edit * @param aHierarchy is the current hierarchy containing aSheet * @param aClearAnnotationNewItems is a reference to a bool to know if the items managed by * this sheet need to have their annotation cleared i.e. when an existing item list is used. * it can happens when the edited sheet used an existying file, or becomes a new instance * of a already existing sheet. */ bool EditSheetProperties( SCH_SHEET* aSheet, SCH_SHEET_PATH* aHierarchy, bool* aClearAnnotationNewItems ); void InitSheet( SCH_SHEET* aSheet, const wxString& aNewFilename ); /** * Load a the KiCad schematic file \a aFileName into the sheet \a aSheet. * * If \a aSheet does not have a valid #SCH_SCREEN object, the schematic is loaded into * \a Sheet. Otherwise, it is appended to the current #SCH_SCREEN object. * * In order to import a schematic a lot of things have to happen to before the contents * of the imported schematic can be appended to the current page. The following list * describes this process: * * - Load the schematic into a temporary #SCH_SHEET object. * - Make sure the imported schematic does not cause any hierarchy recursion issues. * - Verify the imported schematic uses fully qualified #LIB_ID objects (symbol library table). * - Check all of the possible combinations that could cause broken symbol library links * and give the user the option to cancel the append process. The following conditions * are check but they still do not guarantee that there will not be any broken symbol * library links: * - The source schematic is in the current project path and contains symbol library * nicknames not found in the project symbol library table. This can happen if the * schematic is copied to the current project path from another project. * - The source schematic is in a different path and there are symbol library link nicknames * that do not exist in either the current symbol library table or the source project * symbol library table if it exists in the source path. * - The source schematic is in a different path and contains duplicate symbol library * nicknames that point to different libraries. * - Check to see if any symbol libraries need to be added to the current project's symbol * library table. This includes: * - Check if the symbol library already exists in the project or global symbol library * table. * - Convert symbol library URLS that use the ${KIPRJMOD} environment variable to absolute * paths. ${KIPRJMOD} will not be the same for this project. * - Clear all of the annotation in the imported schematic to prevent clashes. * - Append the objects from the temporary sheet to the current page. * - Replace any duplicate time stamps. * - Refresh the symbol library links. * * @param aSheet is the sheet to either append or load the schematic. * @param aHierarchy is the current position in the schematic hierarchy used to test for * possible file recursion issues. * @param aFileName is the file name to load. The file name is expected to have an absolute * path. * * @return True if the schematic was imported properly. */ bool LoadSheetFromFile( SCH_SHEET* aSheet, SCH_SHEET_PATH* aHierarchy, const wxString& aFileName ); /** * Create a new SCH_SHEET_PIN object and add it to \a aSheet at the current cursor position. * * @param aSheet The sheet to add the new sheet pin to. * @return The new sheet pin object created or NULL if the task was aborted by the user. */ SCH_SHEET_PIN* CreateSheetPin( SCH_SHEET* aSheet, SCH_HIERLABEL* aLabel ); /** * Import a hierarchical label with no attached sheet pin. * * @param aSheet The sheet to import the new sheet pin to. */ SCH_HIERLABEL* ImportHierLabel( SCH_SHEET* aSheet ); /** * Removes a given junction and heals any wire segments under the junction * * @param aItem The junction to delete * @param aAppend True if we are updating an ongoing commit */ void DeleteJunction( SCH_ITEM* aItem, bool aAppend = false ); void ConvertPart( SCH_COMPONENT* aComponent ); void SelectUnit( SCH_COMPONENT* aComponent, int aUnit ); /* Undo - redo */ /** * Create a copy of the current schematic item, and put it in the undo list. * * flag_type_command = * UR_CHANGED * UR_NEW * UR_DELETED * UR_WIRE_IMAGE * UR_MOVED * * If it is a delete command, items are put on list with the .Flags member * set to UR_DELETED. * * @note * Edit wires and buses is a bit complex. * because when a new wire is added, a lot of modifications in wire list is made * (wire concatenation): modified items, deleted items and new items * so flag_type_command is UR_WIRE_IMAGE: the struct ItemToCopy is a list of * wires saved in Undo List (for Undo or Redo commands, saved wires will be * exchanged with current wire list * * @param aItemToCopy = the schematic item modified by the command to undo * @param aTypeCommand = command type (see enum UNDO_REDO_T) * @param aAppend = add the item to the previous undo list * @param aTransformPoint = the reference point of the transformation, * for commands like move */ void SaveCopyInUndoList( SCH_ITEM* aItemToCopy, UNDO_REDO_T aTypeCommand, bool aAppend = false, const wxPoint& aTransformPoint = wxPoint( 0, 0 ) ); /** * Create a new entry in undo list of commands. * * @param aItemsList = the list of items modified by the command to undo * @param aTypeCommand = command type (see enum UNDO_REDO_T) * @param aAppend = add the item to the previous undo list * @param aTransformPoint = the reference point of the transformation, * for commands like move */ void SaveCopyInUndoList( const PICKED_ITEMS_LIST& aItemsList, UNDO_REDO_T aTypeCommand, bool aAppend = false, const wxPoint& aTransformPoint = wxPoint( 0, 0 ) ); /** * Restore an undo or redo command to put data pointed by \a aList in the previous state. * * @param aList a PICKED_ITEMS_LIST pointer to the list of items to undo/redo * @param aRedoCommand a bool: true for redo, false for undo */ void PutDataInPreviousState( PICKED_ITEMS_LIST* aList, bool aRedoCommand ); /** * Clone \a aItem and owns that clone in this container. */ void SaveCopyForRepeatItem( SCH_ITEM* aItem ); /** * Return the item which is to be repeated with the insert key. * * Such object is owned by this container, and must be cloned. */ SCH_ITEM* GetRepeatItem() const { return m_item_to_repeat; } EDA_ITEM* GetItem( const KIID& aId ) override; /** * Performs an undo of the last edit WITHOUT logging a corresponding redo. Used to cancel * an in-progress operation. */ void RollbackSchematicFromUndo(); /** * Create a symbol library file with the name of the root document plus the '-cache' suffix, * * This file will contain all components used in the current schematic. * * @param aUseCurrentSheetFilename = false to use the root sheet filename * (default) or true to use the currently opened sheet. * @return true if the file was written successfully. */ bool CreateArchiveLibraryCacheFile( bool aUseCurrentSheetFilename = false ); /** * Create a library \a aFileName that contains all components used in the current schematic. * * @param aFileName The full path and file name of the archive library. * @return True if \a aFileName was written successfully. */ bool CreateArchiveLibrary( const wxString& aFileName ); /** * Plot or print the current sheet to the clipboard. * * @param aDC = wxDC given by the calling print function */ virtual void PrintPage( RENDER_SETTINGS* aSettings ) override; void SetNetListerCommand( const wxString& aCommand ) { m_netListerCommand = aCommand; } /** * Reset the execution flags to defaults for external netlist and bom generators. */ void DefaultExecFlags() { m_exec_flags = wxEXEC_SYNC; } /** * Set (adds) specified flags for next execution of external generator of the netlist or bom. * * @param aFlags = wxEXEC_* flags, see wxExecute docs. */ void SetExecFlags( const int aFlags ) { m_exec_flags |= aFlags; } /** * Clear (removes) specified flags that not needed for next execution of external generator * of the netlist or bom. * * @param aFlags = wxEXEC_* flags, see wxExecute docs. */ void ClearExecFlags( const int aFlags ) { m_exec_flags &= ~( aFlags ); } wxString GetNetListerCommand() const { return m_netListerCommand; } /** * Generates the connection data for the entire schematic hierarchy. */ void RecalculateConnections( SCH_CLEANUP_FLAGS aCleanupFlags ); /** * Allows Eeschema to install its preferences panels into the preferences dialog. */ void InstallPreferences( PAGED_DIALOG* aParent, PANEL_HOTKEYS_EDITOR* aHotkeysPanel ) override; /** * Called after the preferences dialog is run. */ void CommonSettingsChanged( bool aEnvVarsChanged ) override; void ShowChangedLanguage() override; void SyncToolbars() override; void SetScreen( BASE_SCREEN* aScreen ) override; const BOX2I GetDocumentExtents() const override; void FixupJunctions(); void FocusOnItem( SCH_ITEM* aItem ); /** * Convert sheet and symbol legacy time stamp UUIDs to full UUIDs. * * @warning This is a work in progress. It only contains the original code that automatically * updated the UUIDs when loading legacy schematics. This is an incomplete solution * because a way to force a PCB update from schematic with the update symbol links * from references setting must be executed to ensure proper synchronization between * the schematic and board. */ void ConvertTimeStampUuids(); DECLARE_EVENT_TABLE() }; #endif // SCH_EDIT_FRAME_H