/* * This program source code file is part of KiCad, a free EDA CAD application. * * Copyright (C) 1992-2018 jp.charras at wanadoo.fr * Copyright (C) 2013 SoftPLC Corporation, Dick Hollenbeck * Copyright (C) 1992-2021 KiCad Developers, see change_log.txt for contributors. * * This program is free software; you can redistribute it and/or * modify it under the terms of the GNU General Public License * as published by the Free Software Foundation; either version 2 * of the License, or (at your option) any later version. * * This program is distributed in the hope that it will be useful, * but WITHOUT ANY WARRANTY; without even the implied warranty of * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the * GNU General Public License for more details. * * You should have received a copy of the GNU General Public License * along with this program; if not, you may find one here: * http://www.gnu.org/licenses/old-licenses/gpl-2.0.html * or you may search the http://www.gnu.org website for the version 2 license, * or you may write to the Free Software Foundation, Inc., * 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301, USA */ #include #include // for ProcessExecute #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include #include bool SCH_EDIT_FRAME::WriteNetListFile( int aFormat, const wxString& aFullFileName, unsigned aNetlistOptions, REPORTER* aReporter ) { // Ensure all power symbols have a valid reference Schematic().GetSheets().AnnotatePowerSymbols(); if( !ReadyToNetlist( _( "Exporting netlist requires a fully annotated schematic." ) ) ) return false; // If we are using the new connectivity, make sure that we do a full-rebuild if( ADVANCED_CFG::GetCfg().m_IncrementalConnectivity ) RecalculateConnections( nullptr, GLOBAL_CLEANUP ); bool res = true; bool executeCommandLine = false; wxString fileName = aFullFileName; NETLIST_EXPORTER_BASE *helper = nullptr; SCHEMATIC* sch = &Schematic(); switch( aFormat ) { case NET_TYPE_PCBNEW: helper = new NETLIST_EXPORTER_KICAD( sch ); break; case NET_TYPE_ORCADPCB2: helper = new NETLIST_EXPORTER_ORCADPCB2( sch ); break; case NET_TYPE_CADSTAR: helper = new NETLIST_EXPORTER_CADSTAR( sch ); break; case NET_TYPE_SPICE: helper = new NETLIST_EXPORTER_SPICE( sch ); break; case NET_TYPE_SPICE_MODEL: helper = new NETLIST_EXPORTER_SPICE_MODEL( sch ); break; case NET_TYPE_BOM: // When generating the BOM, we have a bare filename so don't strip // the extension or you might string a '.' from the middle of the filename fileName += wxT( "." GENERIC_INTERMEDIATE_NETLIST_EXT ); helper = new NETLIST_EXPORTER_XML( sch ); executeCommandLine = true; break; default: { wxFileName tmpFile = fileName; tmpFile.SetExt( GENERIC_INTERMEDIATE_NETLIST_EXT ); fileName = tmpFile.GetFullPath(); helper = new NETLIST_EXPORTER_XML( sch ); executeCommandLine = true; } break; } NULL_REPORTER devnull; if( aReporter ) res = helper->WriteNetlist( fileName, aNetlistOptions, *aReporter ); else res = helper->WriteNetlist( fileName, aNetlistOptions, devnull ); delete helper; // If user provided a plugin command line, execute it. if( executeCommandLine && res && !m_netListerCommand.IsEmpty() ) { wxString prj_dir = Prj().GetProjectPath(); // strip trailing '/' prj_dir = prj_dir.SubString( 0, prj_dir.Len() - 2 ); // build full command line from user's format string. // For instance, "xsltproc -o %O /usr/local/lib/kicad/plugins/netlist_form_pads-pcb.xsl %I" // becomes, after the user selects /tmp/s1.net as the output file from the file dialog: // "xsltproc -o /tmp/s1.net /usr/local/lib/kicad/plugins/netlist_form_pads-pcb.xsl /tmp/s1.xml" wxString commandLine = NETLIST_EXPORTER_BASE::MakeCommandLine( m_netListerCommand, fileName, aFullFileName, prj_dir ); if( aReporter ) { wxArrayString output, errors; int diag = wxExecute( commandLine, output, errors, m_exec_flags ); wxString msg; aReporter->ReportHead( commandLine, RPT_SEVERITY_ACTION ); if( diag != 0 ) { msg.Printf( _( "Command error. Return code %d." ), diag ); aReporter->ReportTail( msg, RPT_SEVERITY_ERROR ); } else { aReporter->ReportTail( _( "Success." ), RPT_SEVERITY_INFO ); } if( output.GetCount() ) { for( unsigned ii = 0; ii < output.GetCount(); ii++ ) aReporter->Report( output[ii], RPT_SEVERITY_INFO ); } if( errors.GetCount() ) { for( unsigned ii = 0; ii < errors.GetCount(); ii++ ) aReporter->Report( errors[ii], RPT_SEVERITY_ERROR ); } } else { wxExecute( commandLine, m_exec_flags ); } DefaultExecFlags(); // Reset flags to default after executing } return res; } bool SCH_EDIT_FRAME::ReadyToNetlist( const wxString& aAnnotateMessage ) { // Ensure all power symbols have a valid reference Schematic().GetSheets().AnnotatePowerSymbols(); // Symbols must be annotated if( CheckAnnotate( []( ERCE_T, const wxString&, SCH_REFERENCE*, SCH_REFERENCE* ) {} ) ) { // Schematic must be annotated: call Annotate dialog and tell the user why. ModalAnnotate( aAnnotateMessage ); if( CheckAnnotate( []( ERCE_T, const wxString&, SCH_REFERENCE*, SCH_REFERENCE* ) {} ) ) return false; } // Test duplicate sheet names: ERC_TESTER erc( &Schematic() ); if( erc.TestDuplicateSheetNames( false ) > 0 ) { if( !IsOK( this, _( "Error: duplicate sheet names. Continue?" ) ) ) return false; } return true; } void SCH_EDIT_FRAME::sendNetlistToCvpcb() { std::string packet; { NETLIST_EXPORTER_KICAD exporter( &Schematic() ); STRING_FORMATTER formatter; // @todo : trim GNL_ALL down to minimum for CVPCB exporter.Format( &formatter, GNL_ALL | GNL_OPT_KICAD ); packet = formatter.GetString(); // an abbreviated "kicad" (s-expr) netlist // NETLIST_EXPORTER_KICAD must go out of scope so it can clean up things like the // current sheet setting before sending expressmail } Kiway().ExpressMail( FRAME_CVPCB, MAIL_EESCHEMA_NETLIST, packet, this ); }