The client now listens for changes to lastN, selectedEndpoints and maxReceiverVideoQuality in redux to trigger sending bridge message in the new format. This fixes an issue where the stage view <-> tile view changes prompt two receiver constraints messages to be sent, first with the maxHeight update and then with the selected endpoints update.
Change the preferredVideoQuality and maxReceiverVideoQuality values to Ultra HD resolutions. The requested resolution can be as high as 4K to facilitate VPaaS customers to request 4K. The sender video resolution will always max out at the value specified in the video constraints from config.js settings.
Allows to adjust thresholds which control the video quality level
in the thumbnail view.
Changes the default behaviour to request the SD (360p) resolution only
when the thumbnails are at least 360 pixels tall and the height of
720 is required for the high quality level.
The thresholds can be configured with the 'videoQuality.minHeightForQualityLvl'
config property. Check the description in the config.js for more details.
Add a config option with the default value of 2, which will cap the max recv video quality to SD if there's more than 2 participants in the conference while in the tile view mode.