Unit binder: fix hang and DIALOG_WIRE_BUS_PROPERTIES: fix uninitialized variable.

The hang can be Windows specific.
This commit is contained in:
jean-pierre charras 2022-03-19 10:22:41 +01:00
parent 6bf47e44e4
commit 2bba277c5e
2 changed files with 12 additions and 6 deletions

View File

@ -142,10 +142,9 @@ void UNIT_BINDER::onClick( wxMouseEvent& aEvent )
// These are tokens, not strings, so do a select all
textEntry->SelectAll();
}
else
{
aEvent.Skip();
}
// Needed at least on Windows to avoid hanging
aEvent.Skip();
}

View File

@ -64,7 +64,7 @@ bool DIALOG_WIRE_BUS_PROPERTIES::TransferDataToWindow()
{
STROKE_PARAMS stroke;
COLOR4D color;
int dotSize;
int dotSize = -1; // set value to "not found"
for( SCH_ITEM* item : m_items )
{
@ -140,7 +140,14 @@ bool DIALOG_WIRE_BUS_PROPERTIES::TransferDataToWindow()
|| static_cast<const SCH_JUNCTION*>( item )->GetDiameter() == dotSize;
} ) )
{
m_junctionSize.SetValue( dotSize );
if( dotSize >=0 )
m_junctionSize.SetValue( dotSize );
else
{
// No junction found in selected items: disable m_junctionSize
m_junctionSize.Enable( false );
m_junctionSize.SetValue( INDETERMINATE_ACTION );
}
}
else
{