@ -801,6 +801,31 @@ bool SCH_EDIT_FRAME::importFile( const wxString& aFileName, int aFileType )
// Ensure the schematic is fully segmented on first display
BreakSegmentsOnJunctions();
SchematicCleanUp( true );
// Add junctions dots where necessary to get the connectivity right
SCH_TYPE_COLLECTOR components;
auto& schLibTable = *Kiway().Prj().SchSymbolLibTable();
components.Collect( GetScreen()->GetDrawItems(), SCH_COLLECTOR::ComponentsOnly );
for( int cmpIdx = 0; cmpIdx < components.GetCount(); ++cmpIdx )
{
std::vector<wxPoint> pts;
SCH_COMPONENT* cmp = static_cast<SCH_COMPONENT*>( components[cmpIdx] );
cmp->Resolve( schLibTable );
cmp->UpdatePinCache();
cmp->GetConnectionPoints( pts );
for( auto i = pts.begin(); i != pts.end(); ++i )
{
for( auto j = i + 1; j != pts.end(); ++j )
TrimWire( *i, *j, true );
if( GetScreen()->IsJunctionNeeded( *i, true ) )
AddJunction( *i, true );
}
}
GetScreen()->ClearUndoORRedoList( GetScreen()->m_UndoList, 1 );
// Only perform the dangling end test on root sheet.
GetScreen()->TestDanglingEnds();