@ -1573,11 +1573,22 @@ int CONNECTION_GRAPH::RunERC( const ERC_SETTINGS& aSettings, bool aCreateMarkers
{
int error_count = 0;
std::map< wxString, std::vector< std::pair< SCH_ITEM*, CONNECTION_SUBGRAPH* > > > globals;
for( auto subgraph : m_subgraphs )
{
// Graph is supposed to be up-to-date before calling RunERC()
wxASSERT( !subgraph->m_dirty );
for( const auto& item : subgraph->m_items )
{
if( item->Type() == SCH_GLOBAL_LABEL_T )
{
wxString key = static_cast<SCH_TEXT*>( item )->GetText();
globals[ key ].emplace_back( std::make_pair( item, subgraph ) );
}
}
/**
* NOTE:
*
@ -1615,10 +1626,51 @@ int CONNECTION_GRAPH::RunERC( const ERC_SETTINGS& aSettings, bool aCreateMarkers
error_count++;
}
// Some checks are now run after processing every subgraph
// Check for lonely global labels
if( aSettings.check_unique_global_labels )
{
for( auto &it : globals )
{
if( it.second.size() == 1 )
{
ercReportIsolatedGlobalLabel( it.second.at( 0 ).second, it.second.at( 0 ).first );
error_count++;
}
}
}
return error_count;
}
void CONNECTION_GRAPH::ercReportIsolatedGlobalLabel( CONNECTION_SUBGRAPH* aSubgraph,
SCH_ITEM* aLabel )
{
wxString msg;
auto label = dynamic_cast<SCH_TEXT*>( aLabel );
if( !label )
return;
msg.Printf( _( "Global label %s is not connected to any other global label." ),
label->GetShownText() );
auto marker = new SCH_MARKER();
marker->SetTimeStamp( GetNewTimeStamp() );
marker->SetMarkerType( MARKER_BASE::MARKER_ERC );
marker->SetErrorLevel( MARKER_BASE::MARKER_SEVERITY_WARNING );
marker->SetData( ERCE_GLOBLABEL,
label->GetPosition(),
msg,
label->GetPosition() );
SCH_SCREEN* screen = aSubgraph->m_sheet.LastScreen();
screen->Append( marker );
}
bool CONNECTION_GRAPH::ercCheckBusToNetConflicts( CONNECTION_SUBGRAPH* aSubgraph,
bool aCreateMarkers )
{
@ -1860,11 +1912,12 @@ bool CONNECTION_GRAPH::ercCheckNoConnects( CONNECTION_SUBGRAPH* aSubgraph,
if( aSubgraph->m_no_connect != nullptr )
{
bool has_invalid_items = false;
bool has_other_items = false;
SCH_PIN* pin = nullptr;
std::vector<SCH_ITEM*> invalid_items;
// Any subgraph that contains both a pin and a no-connect should not
// contain any other connectable items.
// contain any other driving items.
for( auto item : aSubgraph->m_items )
{
@ -1872,13 +1925,17 @@ bool CONNECTION_GRAPH::ercCheckNoConnects( CONNECTION_SUBGRAPH* aSubgraph,
{
case SCH_PIN_T:
pin = static_cast<SCH_PIN*>( item );
has_other_items = true;
break;
case SCH_LINE_T:
case SCH_JUNCTION_T:
case SCH_NO_CONNECT_T:
break;
default:
has_invalid_items = true;
has_other_items = true;
invalid_items.push_back( item );
}
}
@ -1887,9 +1944,7 @@ bool CONNECTION_GRAPH::ercCheckNoConnects( CONNECTION_SUBGRAPH* aSubgraph,
// (JEY) Yes, I think it should
if( pin && has_invalid_items )
{
SCH_COMPONENT* comp = pin->GetParentComponent();
wxPoint pos = comp->GetTransform().TransformCoordinate( pin->GetPosition() )
+ comp->GetPosition();
wxPoint pos = pin->GetTransformedPosition();
msg.Printf( _( "Pin %s of component %s has a no-connect marker but is connected" ),
GetChars( pin->GetName() ),
@ -1905,6 +1960,23 @@ bool CONNECTION_GRAPH::ercCheckNoConnects( CONNECTION_SUBGRAPH* aSubgraph,
return false;
}
if( !has_other_items )
{
wxPoint pos = aSubgraph->m_no_connect->GetPosition();
msg.Printf( _( "No-connect marker is not connected to anything" ) );
auto marker = new SCH_MARKER();
marker->SetTimeStamp( GetNewTimeStamp() );
marker->SetMarkerType( MARKER_BASE::MARKER_ERC );
marker->SetErrorLevel( MARKER_BASE::MARKER_SEVERITY_WARNING );
marker->SetData( ERCE_NOCONNECT_NOT_CONNECTED, pos, msg, pos );
screen->Append( marker );
return false;
}
}
else
{
@ -1941,22 +2013,18 @@ bool CONNECTION_GRAPH::ercCheckNoConnects( CONNECTION_SUBGRAPH* aSubgraph,
pin->IsPowerConnection() && !pin->IsVisible() )
{
wxString name = pin->Connection( sheet )->Name();
wxString local_name = pin->Connection( sheet )->Name( true );
if( int code = m_net_name_to_code_map.count( name ) )
if( m_global_label_cache.count( name ) ||
( m_local_label_cache.count( std::make_pair( sheet, local_name ) ) ) )
{
if( m_net_code_to_subgraphs_map.count( code ) )
{
if( m_net_code_to_subgraphs_map.at( code ).size() > 1 )
has_other_connections = true;
}
has_other_connections = true;
}
}
if( pin && !has_other_connections && pin->GetType() != PIN_NC )
{
SCH_COMPONENT* comp = pin->GetParentComponent();
wxPoint pos = comp->GetTransform().TransformCoordinate( pin->GetPosition() )
+ comp->GetPosition();
wxPoint pos = pin->GetTransformedPosition();
msg.Printf( _( "Pin %s of component %s is unconnected." ),
GetChars( pin->GetName() ),

View File

@ -345,6 +345,8 @@ private:
* @return true for no errors, false for errors
*/
bool ercCheckLabels( CONNECTION_SUBGRAPH* aSubgraph, bool aCreateMarkers );
void ercReportIsolatedGlobalLabel( CONNECTION_SUBGRAPH* aSubgraph, SCH_ITEM* aLabel );
};
#endif

View File

@ -49,17 +49,19 @@ wxString DRC_ITEM::GetErrorText() const
case ERCE_PIN_TO_PIN_ERROR:
return wxString( _("Conflict problem between pins. Severity: error") );
case ERCE_HIERACHICAL_LABEL:
return wxString( _("Mismatch between hierarchical labels and pins sheets"));
return wxString( _("Mismatch between hierarchical labels and pins sheets") );
case ERCE_NOCONNECT_CONNECTED:
return wxString( _("A pin with a \"no connection\" flag is connected"));
return wxString( _("A pin with a \"no connection\" flag is connected") );
case ERCE_NOCONNECT_NOT_CONNECTED:
return wxString( _("A \"no connection\" flag is not connected to anything") );
case ERCE_LABEL_NOT_CONNECTED:
return wxString( _("A label not connected to any other item") );
case ERCE_SIMILAR_LABELS:
return wxString( _("Labels are similar (lower/upper case difference only)") );
return wxString( _("Labels are similar (lower/upper case difference only)" ) );
case ERCE_SIMILAR_GLBL_LABELS:
return wxString( _("Global labels are similar (lower/upper case difference only)") );
return wxString( _("Global labels are similar (lower/upper case difference only)" ) );
case ERCE_DIFFERENT_UNIT_FP:
return wxString( _("Different footprint assigned in another unit of the same component") );
return wxString( _("Different footprint assigned in another unit of the same component" ) );
case ERCE_DIFFERENT_UNIT_NET:
return wxString( _("Different net assigned to a shared pin in another unit of the same component" ) );
case ERCE_BUS_ALIAS_CONFLICT:
@ -74,6 +76,8 @@ wxString DRC_ITEM::GetErrorText() const
return wxString( _( "No nets are shared between two bus items" ) );
case ERCE_BUS_TO_NET_CONFLICT:
return wxString( _( "Invalid connection between bus and net items" ) );
case ERCE_GLOBLABEL:
return wxString( _( "Invalid connection between bus and net items" ) );
default:
wxFAIL_MSG( "Missing ERC error description" );
return wxString( wxT("Unknown.") );

View File

@ -369,7 +369,7 @@ void Diagnose( NETLIST_OBJECT* aNetItemRef, NETLIST_OBJECT* aNetItemTst,
SCH_SCREEN* screen;
ELECTRICAL_PINTYPE ii, jj;
if( aDiag == OK )
if( aDiag == OK || aMinConn < 1 )
return;
/* Create new marker for ERC error. */
@ -383,40 +383,6 @@ void Diagnose( NETLIST_OBJECT* aNetItemRef, NETLIST_OBJECT* aNetItemTst,
wxString msg;
if( aMinConn < 0 )
{
#if 0
if( aNetItemRef->m_Type == NET_HIERLABEL || aNetItemRef->m_Type == NET_HIERBUSLABELMEMBER )
{
msg.Printf( _( "Hierarchical label %s is not connected to a sheet label." ),
GetChars( aNetItemRef->m_Label ) );
marker->SetData( ERCE_HIERACHICAL_LABEL,
aNetItemRef->m_Start,
msg,
aNetItemRef->m_Start );
}
else if( aNetItemRef->m_Type == NET_GLOBLABEL )
{
msg.Printf( _( "Global label %s is not connected to any other global label." ),
GetChars( aNetItemRef->m_Label ) );
marker->SetData( ERCE_GLOBLABEL,
aNetItemRef->m_Start,
msg,
aNetItemRef->m_Start );
}
else
{
msg.Printf( _( "Sheet label %s is not connected to a hierarchical label." ),
GetChars( aNetItemRef->m_Label ) );
marker->SetData( ERCE_HIERACHICAL_LABEL,
aNetItemRef->m_Start,
msg,
aNetItemRef->m_Start );
}
#endif
return;
}
ii = aNetItemRef->m_ElectricalPinType;
wxString cmp_ref( "?" );
@ -426,19 +392,6 @@ void Diagnose( NETLIST_OBJECT* aNetItemRef, NETLIST_OBJECT* aNetItemTst,
if( aNetItemTst == NULL )
{
if( aMinConn == NOC ) /* Only 1 element in the net. */
{
msg.Printf( _( "Pin %s (%s) of component %s is unconnected." ),
aNetItemRef->m_PinNum,
GetChars( GetText( ii ) ),
GetChars( cmp_ref ) );
marker->SetData( ERCE_PIN_NOT_CONNECTED,
aNetItemRef->m_Start,
msg,
aNetItemRef->m_Start );
return;
}
if( aMinConn == NOD ) /* Nothing driving the net. */
{
if( aNetItemRef->m_Type == NET_PIN && aNetItemRef->m_Link )
@ -456,16 +409,6 @@ void Diagnose( NETLIST_OBJECT* aNetItemRef, NETLIST_OBJECT* aNetItemTst,
aNetItemRef->m_Start );
return;
}
if( aDiag == UNC )
{
msg.Printf( _( "More than 1 pin connected to an UnConnect symbol." ) );
marker->SetData( ERCE_NOCONNECT_CONNECTED,
aNetItemRef->m_Start,
msg,
aNetItemRef->m_Start );
return;
}
}
if( aNetItemTst ) /* Error between 2 pins */

View File

@ -59,6 +59,7 @@ enum ERCE_T
ERCE_PIN_TO_PIN_ERROR, // pin connected to an other pin: error level
ERCE_HIERACHICAL_LABEL, // mismatch between hierarchical labels and pins sheets
ERCE_NOCONNECT_CONNECTED, // a no connect symbol is connected to more than 1 pin
ERCE_NOCONNECT_NOT_CONNECTED, // a no connect symbol is not connected to anything
ERCE_LABEL_NOT_CONNECTED, // label not connected to anything
ERCE_SIMILAR_LABELS, // 2 labels are equal fir case insensitive comparisons
ERCE_SIMILAR_GLBL_LABELS, // 2 labels are equal fir case insensitive comparisons
@ -70,6 +71,7 @@ enum ERCE_T
ERCE_BUS_LABEL_ERROR, // a label attached to a bus isn't in bus format
ERCE_BUS_TO_BUS_CONFLICT, // a connection between bus objects doesn't share at least one net
ERCE_BUS_TO_NET_CONFLICT, // a bus wire is graphically connected to a net port/pin (or vice versa)
ERCE_GLOBLABEL, // a global label is unique
};
/* Minimal connection table */