Use only a physical connection to determine flashing of pads.
Checking for proper nets just confuses things when the nets are set wrongly for some reason. This way we generate clearer DRC errors. Fixes https://gitlab.com/kicad/code/kicad/issues/10645
This commit is contained in:
parent
d56e488f2d
commit
f8d15a641a
|
@ -378,7 +378,7 @@ void CONNECTIVITY_DATA::PropagateNets( BOARD_COMMIT* aCommit, PROPAGATE_MODE aMo
|
|||
|
||||
|
||||
bool CONNECTIVITY_DATA::IsConnectedOnLayer( const BOARD_CONNECTED_ITEM *aItem, int aLayer,
|
||||
std::vector<KICAD_T> aTypes ) const
|
||||
std::vector<KICAD_T> aTypes, bool aIgnoreNets ) const
|
||||
{
|
||||
CN_CONNECTIVITY_ALGO::ITEM_MAP_ENTRY &entry = m_connAlgo->ItemEntry( aItem );
|
||||
|
||||
|
@ -397,7 +397,7 @@ bool CONNECTIVITY_DATA::IsConnectedOnLayer( const BOARD_CONNECTED_ITEM *aItem, i
|
|||
{
|
||||
if( connected->Valid()
|
||||
&& connected->Layers().Overlaps( aLayer )
|
||||
&& connected->Net() == aItem->GetNetCode()
|
||||
&& ( connected->Net() == aItem->GetNetCode() || aIgnoreNets )
|
||||
&& matchType( connected->Parent()->Type() ) )
|
||||
{
|
||||
return true;
|
||||
|
|
|
@ -201,7 +201,8 @@ public:
|
|||
unsigned int GetUnconnectedCount() const;
|
||||
|
||||
bool IsConnectedOnLayer( const BOARD_CONNECTED_ITEM* aItem,
|
||||
int aLayer, std::vector<KICAD_T> aTypes = {} ) const;
|
||||
int aLayer, std::vector<KICAD_T> aTypes = {},
|
||||
bool aIgnoreNets = false ) const;
|
||||
|
||||
unsigned int GetNodeCount( int aNet = -1 ) const;
|
||||
|
||||
|
|
|
@ -237,7 +237,7 @@ bool PAD::FlashLayer( int aLayer ) const
|
|||
|
||||
return board && board->GetConnectivity()->IsConnectedOnLayer( this,
|
||||
static_cast<int>( aLayer ),
|
||||
types );
|
||||
types, true );
|
||||
|
||||
case PAD_ATTRIB::NPTH:
|
||||
if( GetShape() == PAD_SHAPE::CIRCLE && GetDrillShape() == PAD_DRILL_SHAPE_CIRCLE )
|
||||
|
|
Loading…