1) if a legacy model references a library then we need to see if said
libraray exists and read model from it if so
2) legacy node ordering is by index, not pin name
3) we can't auto-generate a pin map when we don't know the pin names,
so don't try
Also moves passive RLC inference out from migration to just-in-time
creation for the simulator or netlisting.
Also fixes a version guard mismatch because the spice migration was
done inside UpdateSymbolInstances (which has its own version guard).
Also changed UpdateSymbolInstances to UpdateSymbolInstanceData so
someone else in the future doesn't think it's a general-purpose symbol
instance updater.
Currently this lives behind the advanced config flag `UseClipper2`.
Enabling this flag will route all Clipper-based calls through the
Clipper2 library instead of the older Clipper. The changes should be
mostly transparent.
Of note, Clipper2 does not utilize the `STRICTLY_SIMPLE` flag because
clipper1 did not actually guarantee a strictly simple polygon.
Currently we ignore this flag but we may decide to run strictly-simple
operations through a second NULL union to simplify the results as much
as possible.
Additionally, the inflation options are slightly different. We cannot
choose the fallback miter. The fallback miter is always square. This
only affects the CHAMFER_ACUTE_CORNERS option in inflate, which does not
appear to be used.
Lastly, we currently utilize the 64-bit integer coordinates for
calculations. This appears to still be faster than 32-bit calculations
in Clipper1 on a modern x86 system. This may not be the case for older
systems, particularly 32-bit systems.
pad of a given number.
Also improves other DRC logic to tighten up the net-tie rules now that
we know which pads are allowed to short with which other pads.
Also removes the "Overlapping pads" DRC violation now that we know
whether or not overlapping pads in a net-tie footprint constitute a
short.
Fixes https://gitlab.com/kicad/code/kicad/issues/12506
When the via is first and not second in our ordering, the hole-copper
clearance was not checked as the track did not have a hole.
We also calculated the NPTH-via clearance incorrectly in the inspector
All labels need to be attached to a net that has at least 2 pins in
order for this to be a valid net. To check for the existing pins, we
need to interate over all subgraphs in the net, counting pins