For some kinds of issues, we want a way to point them out but
we don't need to keep the user from being able to close the
dialog. A separate Validate button lets the user check for
issues if desired, but these issues are not "fatal" and can
be ignored if the user wishes.
Also don't load the footprints up front. The whole purpose of the
footprint-info stuff is to have enough info about the footprints to
filter them *without* loading. After that just load individual
footprints as we need them.
Fixes https://gitlab.com/kicad/code/kicad/issues/6177
So the new steals-focus protection stuff works well when there's a
focused control, but not as well when there's a modal dialog up which
happens not to have a focused control (or worse, a focusable control).
This adds a second mechanism for also checking to see if a modal dialog
is up (something that wxWidgets, true to form, makes very difficult).
Fixes https://gitlab.com/kicad/code/kicad/issues/6520
The infobar changes the size of the visible screen, so adding/removing
it will shift the screen center, causing the position of onscreen
objects to move up/down. This changes the sizing to pin the bottom
corner position when showing/hiding the infobar
Fixes https://gitlab.com/kicad/code/kicad/issues/5776
You can now enable and disable snap to grid when drawing/editing across
all apps. You can also tie snap to grid to the visibility of the grid
to allow rapid enable/disable via grid display.
This commit modifies the UNIT_BINDER class to invoke the ORIGIN_TRANSFORMS
methods to support Display Origin Transforms.
The EDA_DRAW_FRAME class is modified to instantiate an ORIGIN_TRANSFORMS
object providing null transforms. A function is provided to allow the
UNIT_BINDER to find the ORIGIN_TRANSFORMS object in an overrideable manner.
Display warning infobar in the board/schematic setup when no project
is loaded, since most of the settings in those dialogs are saved in
the project and not in the board/schematic file.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/4868
Short net names are not unique; full names with paths must be used.
Added a grid cell renderer that does the escaping, to make it easier
to display net names in grid cells.
Once you unescape a net name, you can't go back to the escaped form
because you can't assume which `/` should be {slash} and which `/`
Because of this, we cannot use Unescape/Escape on the data model in
the netclass setup panel, and instead do the Unescape in the view.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/5331