In order to avoid confusion when loading legacy schematics, updating time
stamp UUIDs is no longer performed. If users where not experiencing issues
with time stamp clashes with shared schematics then this was probably a
case of me being overly cautious.
The original conversion code has be moved to
SCH_EDIT_FRAME::ConvertTimeStampUuids() so the working functionality is
not lost. This function should not be used until a way is found to update
the board from the schematics with the appropriate settings.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.
The new file formats are now the default in both the schematic and symbol
library editors. Existing symbol libraries will be saved in their current
format until new features are added to library symbols. Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted. Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.
When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier. The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.
The next save after loading a legacy schematic file will be converted to
the s-expression file format. Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.
Appending schematics requires that the schematic to append has already been
converted to the new file format. This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.
The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol. This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed. It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.
When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded. Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.
Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically. No external manipulation of this library cache should ever
occur.
ADDED: S-expression schematic and symbol library file formats.
* Push all sizing operations into EDA_BASE_FRAME
* Save the unmaximized window size when maximizing
so that we can then save it in the config if the
window is maximized. Otherwise the config ends up
with the maximized size saved, and weird behavior
occurs when unmaximizing on the next opening.
Now only reposition a window if it is completely on a
disconnected display or if only one corner is on screen
and it is within a region close to the screen border.
CHANGED: Window position on startup should be preserved more
Please note that the symbol cache is not embedded in the schematic file
to allow for round robin testing with the existing file format. Once
the parser round robin testing is complete, the symbol cache will be
embedded in the schematic file.
Keeping a pointer to the actual file history inside a special
file history menu led to many cases of use after free crashes,
so instead rework the actual file history to add the menu
items.
Fixes https://gitlab.com/kicad/code/kicad/issues/3741
CHANGED: Settings are now stored in versioned sub-directories
ADDED: First-run dialog for migrating settings from a previous version
CHANGED: Settings are now stored as JSON files instead of wxConfig-style INI files
CHANGED: Color settings are now all stored in a separate settings file
CHANGED: The symbol editor and footprint editor now have their own settings files
CHANGED: Color settings are no longer exposed through BOARD object
CHANGED: Page layout editor now uses Eeschema's color scheme
Settings are now managed through a central SETTINGS_MANAGER held by PGM_BASE.
Existing settings will be migrated from the wxConfig format on first run of each application.
Per-application settings are now stored in one class for each application.
If the point editor is active and a change is made, the tool was shut down after
deleting the board data, in the frame Dtor.
Therefore a crash happened because a call to GetScreen()->SetModify(); using a null pointer,
and after the test for modifications was done.
Now tools are stopped when closing the window, before any test for modifications.
This moves EESchema DLIST structures to rtree. These changes are more
fundamental than the pcbnew changes from 9163ac543888c01d11d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
and switch to the paren sheet from the context menu.
Mainly, change the way the dialog is managed from the sch_edit_frame:
the pointer to find the created dialog is replaced by a call to wxWidows::FindWindowByName().
Using a pointer set and cleared by events is a recipe for crashes.
ADD: User can now decide to keep the hierarchy navigator open while working
on a schematic.
This behavior can be configured in eeschema->preferences->eeschema->Editing options.
Create an IsContentModified() function in each frame
that provides if the content has been modified, and
use that instead of always copying the checks.
ADDED: a config option to select (when clicking on a pin) the parent symbol
or only the pin.
Previously, when cliking on a pin, the parent symbol was selected.
Allowing the pin selection is mandatory in cross probing, and to display the pin
characteristics in some cases, for instance if a pin is flagged by the ERC tooL.
Add missing check for root sheet when searching sheet hierarchies for
already loaded schematics. This prevents the root sheet from being
omitted when adding new sheets using the root sheet file name.
CHANGED: Make file name tests case sensitive so that schematic sheet
file names on non-Windows systems can be uses as expected.
Warn users when attempting to use schematic file names that only vary
by case sensitivity that doing so will result in a project that is not
portable to Windows.
Fixes lp:1843415
https://bugs.launchpad.net/kicad/+bug/1843415
CHANGED: No longer call schematics noname.sch in standalone mode,
instead don't given them any name so the user can choose on save.
Fixes: lp:1852607
* https://bugs.launchpad.net/kicad/+bug/1852607
We have different requirements than sheet paths for netlists,
so going through that code and then doing a lot of conversions
just ends up with a mess.
We now generate the path directly from the SCH_SHEET_PATH.
Fixes: lp:1852353
* https://bugs.launchpad.net/kicad/+bug/1852353
The new connectivity algorithm had a tendency to cleanup
globally, but that could insert undo records from other sheets
into the current screen's undo stack. Needless to say, this
was a recipie for segfaults.
Fixes: lp:1846247
* https://bugs.launchpad.net/kicad/+bug/1846247
While it's tempting to look at the changed flag that TestDanglingEnds
returns, it's insuficient as the connectivity algorithm might have
already updated it (and ignored the changed flag).
Fixes: lp:1835107
* https://bugs.launchpad.net/kicad/+bug/1835107
Check for symbol libraries that somehow ended up in the project file
after remapping occurred and remove all of them to prevent potentially
broken symbol library links.
Add nagware dialog to warn the user and a checkbox to never show the
dialog again.
Fixes lp:1838185
https://bugs.launchpad.net/kicad/+bug/1838185
Also rewrites the PCBNew Find dialog to make use of the above, including:
1) searching in user-defined footprint fields
2) searching in pcb text
3) a history list in the search popup
4) case sensitive searching
5) word sensitive searching
6) the ability to turn wildcard searching on/off
7) better placement of the result when the dialog obscures part of the
window
Fixes: lp:1838006
* https://bugs.launchpad.net/kicad/+bug/1838006
Previously, for instance after modifying preferences or language,
they were rebuilt but the tools state was not set due to a missing call to SyncToolbars() after rebuilding.