When an attempt to resolve a library symbol link having a library
nickname that was no longer found in the symbol library table, the
symbol resolution was not falling back to the cache library due to
a silently handled exception. Add check for valid symbol library
table nickname before attempting to resolve symbol link to prevent
exception bypassing falling back to the cache library.
Fixes lp:1740609
https://bugs.launchpad.net/kicad/+bug/1740609
A new legacy symbol library plugin deletes all of the aliases from each
LIB_PART object that it owns cause an assertion in the dtor which calls
GetName() which checks for an empty alias list to prevent a segfault.
Remove the call to GetName() from the dtor trace message.
Fixes lp:1740597
https://bugs.launchpad.net/kicad/+bug/1740597
Store the currently-edited item in the base screen class
instead of the libedit_frame. This allows us to access it
for double-click disambiguation and harmonizes the library
editor with the schematic editor code that already does this.
Fixes: lp:1738694
* https://bugs.launchpad.net/kicad/+bug/1738694
The GetName() method attempts to access the first LIB_ALIAS pointer in
the m_aliases member without checking if m_aliases is empty. This
should never happen because a new LIB_PART creates a LIB_ALIAS object
in the ctor. Some how, this is getting bypassed and causing Eeschema
to crash in the LIB_PART dtor on debug builds. GetName() now checks
for an empty alias list to prevent a null pointer segfault.
Fixes lp:1739614
https://bugs.launchpad.net/kicad/+bug/1739614
Move the OSX dialog fix ups later so they come after some wxWindow
deferred processing.
Also provides a facility for doing a selectAll in each text field
so that tabbing between text fields behaves correctly.
Fixes: lp:1599157
* https://bugs.launchpad.net/kicad/+bug/1599157
This patch adds functionality to the Pcbnew draw tool to show the dx and
dy of the current segment being drawn if the relative origin (pressing
spacebar) is not already set (i.e. if those coordinates are ( 0, 0 ) ).
You can set the relative origin while using the draw tool by pressing
spacebar. The relative origin is reset on exit of the tool.
fixes: lp:1736133
* https://bugs.launchpad.net/kicad/+bug/1736133
Passing an empty path to the 3D model select dialog results in the file
select control displaying the root path which requires the user to drill
down to get to the 3D models. Use the KISYS3DMOD path as the default
and fall back to the project path as required for the initial file
select control path.
Clean up some coding policy violations.
Fixes lp:1737094
https://bugs.launchpad.net/kicad/+bug/1737094
Improve dialog layout and fix UI policy issues with all of the dialog
boxes in the Gerbview and Pcbnew code paths.
Updated the use of component to footprint where appropriate.
Improve dialog layout and fix UI policy issues with all of the dialog
boxes in the common, 3D viewer, CvPcb, and Eeschema code paths.
Updated the use of component to symbol.
Replace all instances of "component" and "part" with "symbol" when
referring to schematic and library symbols.
Replace all instances of "component" with "footprint" when referring to
board and library footprints.
Minor dialog layout fixes to some of the dialogs impacted by the UI
string changes.
Remove redundant sizers from environment variable dialog.
Improve sizers and layout spacing of environment variable and environ-
ment variable edit dialogs.
Remove path from dialog box titles since environment variables are not
limited to file paths.
Improved help messages for both environment variable and environment
variable edit dialogs.
Restore highlighting of externally defined environment variables.
Refresh is used in the python domain to refresh the display with the current
design. If something has changed, board connectivity likely needs rebuilding.
If using GAL canvas, update its display db.
The remapping utility would create a new project specific library when a
symbolic link pointed to a library already defined in the symbol library
table. Now the comparison checks to see if the library path and file
name are actually a symbolic link if the file names are not the same when
the symbol library table entry is a file name rather than a URL. URLs
are simple string comparisons.
Disable the remap button after the remapping completed.
Remove some commented out code from the edit symbol in schematic dialog.
Fixes lp:1738634
https://bugs.launchpad.net/kicad/+bug/1738634
Allows buses to acquire junctions based on their connections. Buses
can only have junctions with other buses. Also allows buses to be
draggable junctions for collections
Improved the selection heuristics to keep footprints in the
disambiguation menu when they contain pads with high pad-to-footprint
area ratio.
In other words: make it possible to select a footprint when
most of its area is taken by a pad. Previously pads were given the
priority, so it was very tricky to select the parent footprint.
Fixes: lp:1739425
* https://bugs.launchpad.net/kicad/+bug/1739425