They don't define a KiCad string class, so the header file name was
somewhat misleading. But the fact that they didn't match definitely
made coding more difficult.
This is because we don't yet support radial dimensions.
Also fixes a bug where we fail to read an Altium circular track. We
now convert it to a pair of 180-degree arcs.
Also fixes a bug where we were failing to import prefixes on linear
dimensions.
Fixes https://gitlab.com/kicad/code/kicad/issues/8789
1) Fix a couple of bugs in case processing
2) Make case processing more explicit to prevent more (1)
3) Move label processing to AltiumSpecialStringsToKiCadVariables
4) Strip double-quotes from special strings (and add test cases)
5) Change PROJECTNAME to just filename, not full path
6) PROJECTREV and REVISION are two different things
7) Add support for Altium's Application_BuildNumber
8) Fix some issues in trimming spaces around special strings
wxString::Format is redundant in a wxLogXXX call.
Error messages should generally be translatable.
Error messages should use generally consistent sentence forms.
This was leaking windows headers and partial wx headers to 1084 compilation units......
This also means math/util.h is leaking to 1084 compilation units which seems a bit high too.
Previous assumption of 100mil grid in CADSTAR schematic designs has
been proven to be incorrect. Let's use the "working grid" in the
original design instead.
- Rename member variable names to use the 'm_' prefix
- Rename a few object types that clashed with KiCad object names, such
as BOARD and SCHEMATIC, to avoid the use of '::' to access the KiCad
objects.
- Remove some unused code.
* Fix multi line text alignment.
* Parse schematic frame objects and convert them to lines.
* Make implicit global labels normal size so they can easily be seen.
* Move sheet fields to a more sensible position.
* Parse schematic symbol instances before wires so that the implicit power
connections can properly be tested. This will be used at a later time.
* Scale label text size down to allow for differences in label offset and
graphical items.
Use terminal pin number (i.e. from the symbol definition) when the pin
number is undefined in the part.
This fixes a bug that resulted in symbols with "0" as the pin numbers.
- Load Fields in the library items as well as schematic instances
- Remove invalid characters (e.g. '\n', '\t', '\r') in fields
- Load footprint field (assume that the footprint library name
is the same as the filename of the schematic)
Architecture of the parser changed to have a shared PARSER_CONTEXT between all the individual parsers.
Parses CADSTAR fields such as <@DESIGN_TITLE@> or <@SHEET_NUMBER@> and replaces with an equivalent KiCad Text Variable.