Commit Graph

11 Commits

Author SHA1 Message Date
Oliver Walters 0f6ec7632b Enable multi-layer for keepout zones
- Load / save from PCB file correctly
- Doesn't display properly yet
- Keepout only actually applies to one layer (for now)
2017-09-27 10:34:59 +02:00
Jon Evans 3ec28e2acf Refactor layer enumerations to all live in the same place 2017-03-30 16:01:48 -04:00
jean-pierre charras 77249d9b2d Minor fixes: remove a few useless includes and move a few others to the right file. Remove a few coverity warnings about not initialized members.
Minor bug fix: Zone duplicate zone in legacy mode: duplicate a zone to the same layer (and therefore  the same location) is no more allowed.
2015-05-15 14:49:11 +02:00
Wayne Stambaugh f12953855e More missing source license fixes. 2014-10-23 13:53:38 -04:00
Dick Hollenbeck 4578ea8b9e 1) Add 32 Cu Layers.
2) Change from legacy Cu stack to counting down from top=(F_Cu or 0).
   The old Cu stack required knowing the count of Cu layers to make
   sense of the layer number when converting to many exported file types.
   The new Cu stack is more commonly used, although ours still gives
   B_Cu a fixed number.
3) Introduce class LSET and enum LAYER_ID.
4) Change *.kicad_pcb file format version to 4 from 3.
5) Change fixed names Inner1_Cu-Inner14_Cu to In1_Cu-In30_Cu and their
   meanings are typically flipped.
6) Moved the #define LAYER_N_* stuff into legacy_plugin.cpp where they
   can die a quiet death, and switch to enum LAYER_ID symbols throughout.
7) Removed the LEGACY_PLUGIN::Save() and FootprintSave() functions.
   You will need to convert to the format immediately, *.kicad_pcb and
   *.kicad_mod (=pretty) since legacy format was never going to know
   about 32 Cu layers and additional technical layers and the reversed Cu
   stack.
2014-06-24 11:17:18 -05:00
Lorenzo Marcantonio 9fd79dfa91 Implemented the LAYER_NUM typedef (LAYER was already taken as a class name...) to represent a layer number. 2013-03-31 15:27:46 +02:00
jean-pierre charras f20bf0d217 Pcbnew: more about keepout areas: remove keepout for pads option and add keepout for copper zones option.
Export keepout to Specctra DSN file.
2012-07-14 18:27:25 +02:00
jean-pierre charras 018b080001 Pcbnew: Add keepout areas (Copper zones without tracks or/and vias).
This is *a work in progress*, so some features are missing, and/or could be modified.
Mainly keepout zones are not yet exported to autorouters, and pads are not taken in account.
Some code cleanup in polygon.*
2012-07-13 20:55:29 +02:00
jean-pierre charras 1f50b2c767 Pcbnew: Fix an other compatibility issue in kicad nanometers. 2012-06-17 20:29:11 +02:00
Marco Mattila b536b1cf82 Add module and pad local parameters for pad-zone connections (thermal, solid etc.) in pcbnew. 2012-02-25 01:23:46 +02:00
Dick Hollenbeck 6c04e60587 see CHANGELOG.txt 2012-02-05 23:44:19 -06:00