- Previously a warning was generated even for not connectable pads
(pads not on copper layers or without pad name).
- The test is now optional and is disabled by default.
(pads without corresponding pin is schematics are a frequent case)
Fixes: lp:1852444
https://bugs.launchpad.net/kicad/+bug/1852444
It was a regression from 5.02 version.
The block of new footprints to place has now its reference point (the point that is on the graphic cursor) fixed.
This is the first footprint loaded from the list.
Make sure the view is rebuilt before selecting the new footprints
so that they're shown only in the selection overlay.
Don't start the drag until the dialog is closed so we don't have
a bunch of extraneous mouse warping.
Fixes: lp:1775265
* https://bugs.launchpad.net/kicad/+bug/1775265
Shorten and improve informational content of messages, errors and
warnings.
Remove redundant info messages when they shadow an action, warning
or error message.
Improve title of "Update Footprints" to make it clear that it's
recreating footprints which have different assignments rather than
updating footprints from the library.
Don't perform the dryRun twice.
Don't use the old netlist method of loading footprints. We get
better error reporting if we do it ourselves.
Be more careful checking the last pad when checking for single-pad
nets. If the last pad has no net then pad != previouspad at the
end of the loop.
Fixes: lp:1787255
* https://bugs.launchpad.net/kicad/+bug/1787255
Small icons for dialog browse, refresh, and row operations.
Icons in B&W so they don't over-emphasize with respect to other
controls in the dialog.
Layout cleanup for consistency. Removal of the blank space to
left of the fields list in the Global Fields Editor, and addition
of column-sizing-to-list-width.
More even spacing for buttons in html report panel.
Honor platform conventions for action button order and layout.
Move netlist importer to update-pcb-from-schematic algorithm
(display messages and then update instead of "dry run" checkbox)
(cherry picked from commit b21e19d)
It can be useful to have similar class messages grouped together so that
error messages in a larger report don't get lost among the
warning/info/action messages.
This patch allows sorting of messages for dialogs that benefit from
organization. Default behavior of reporter messages remains
unchanged by this patch.
Fixes: lp:1772090
* https://bugs.launchpad.net/kicad/+bug/1772090
BOARD::GetBoundingBox() now directly calls BOARD::ComputeBoundingBox()
and there is a new method BOARD::GetBoardEdgesBoundingBox() used for
call sites that needed to use ComputeBoundingBox( true ) in the past.
This allows COMMON_TOOLS to implement ZoomFitScreen without knowledge
of the BOARD class.
New virtual class ACTIONS is added as a member to EDA_DRAW_FRAME so
that the TOOL_DISPATCHER can have access to the appropriate derived
version of TranslateLegacyId()