Commit Graph

100 Commits

Author SHA1 Message Date
Jeff Young f50de028fb Make plotting of PDF property popups optional. 2023-10-21 21:52:51 +01:00
Jeff Young 0310973e3f Push TEXT_SPIN_STYLE from SCH_TEXT out to SCH_LABEL_BASE.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/15444
2023-09-07 17:42:51 +01:00
Seth Hillbrand f7f67c6d53 Sort the bus alias set by name
If we place pointers in a set, they are sorted by the pointer value in
memory, not the data, so we need a custom comparator

Fixes https://gitlab.com/kicad/code/kicad/-/issues/11890
2023-07-21 09:03:35 -07:00
Jeff Young 96073402ce Don't accidentally add NULL ptrs to the LibSymbols cache.
Operator[] will add a blank element if it isn't found in the map.

Probably Sentry KICAD-23Y.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/14927
2023-06-11 15:50:24 +01:00
Mike Williams 959a19a461 Power Symbols: automatically fix mismatched legacy symbols, add tests
Has netlist generation test for legacy power symbols, and test for
fixing legacy mismatched power symbol text fields and invisible pin names.
2023-02-22 18:01:47 +00:00
Wayne Stambaugh c88c4e1200 Fix schematic update library symbols issues.
Rather than update library symbols one at a time, queue them up by
schematic symbol to prevent multiple updates to the same symbol in
complex hierarchies.  This also removes all of the library symbols
first which will clear out all of the library symbol variants that
were created by modifying library symbols in place and/or changes to
the symbol in the library.

Don't add new variant library symbol if an equivalent variant already
exists in the schematic local cache.  This prevents duplicate library
symbols from being added to the local cache when the first variant in
the cache does not match that of the symbol being added.
2023-02-02 15:54:24 -05:00
Roberto Fernandez Bautista c7f33e21f8 Extract SCH_SCREEN::GetNeededJunctions from AddJunctionsIfNeeded 2023-01-15 19:17:39 +01:00
Roberto Fernandez Bautista 7332c0c54d Move SCH_EDIT_FRAME::GetSchematicConnections into SCH_SCREEN::GetConnections 2023-01-15 19:17:38 +01:00
Roberto Fernandez Bautista 64105dcf84 Extract GetBusesAndWires function out of SCH_EDIT_FRAME::BreakSegments
This function is called by SCH_EDIT_FRAME::AddJunction
2023-01-15 19:17:38 +01:00
Jeff Young d65cf1b457 Check parameters before assuming we can handle the model.
Fixes https://gitlab.com/kicad/code/kicad/issues/13444
2023-01-08 18:00:22 +00:00
Wayne Stambaugh d99e09014b Rename SYMBOL_INSTANCE_REFERENCE to SCH_SYMBOL_INSTANCE. 2023-01-04 15:39:50 -05:00
Jeff Young 38906397d2 Move V6->V7 sim model migration from sheets to screens.
Also moves passive RLC inference out from migration to just-in-time
creation for the simulator or netlisting.

Also fixes a version guard mismatch because the spice migration was
done inside UpdateSymbolInstances (which has its own version guard).

Also changed UpdateSymbolInstances to UpdateSymbolInstanceData so
someone else in the future doesn't think it's a general-purpose symbol
instance updater.
2022-12-06 16:01:18 +00:00
Wayne Stambaugh 349de90bb0 Fix Altium schematic importer bug(s).
Fixes https://gitlab.com/kicad/code/kicad/-/issues/11412
2022-10-31 10:03:35 -04:00
Wayne Stambaugh a11c40197f Expunge default symbol instance from schematic file format.
Now that importing hierarchical sheets "properly" imports instance data,
the default symbol instance setting doesn't have any meaning.
2022-10-04 15:42:41 -04:00
Wayne Stambaugh 2b387ae9c3 Move schematic symbol instance data back into symbol definition.
This change reverts the storage of all symbol instance data in the root
schematic.  This was done because it's not possible to reuse instance
data when importing from sub-sheets.

There has been a fundamental change in how sheet paths are store in the
instance data.  The root schematic UUID is always used when saving the
instance data.  To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project.  This provides a way
to determine the project that stored the instance data.  All uses of paths
without root sheet have been expunged from the code.

The sheet instance data is still saved only in the root sheet for the
time being.  New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number.  Sheet page
numbers will not be imported.

Added project name to instance data to improve the readability of the
schematic file format.  It also creates an opportunity to remove orphaned
instance data by project name rather than cryptic UUIDs.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
2022-10-02 15:06:42 -04:00
Wayne Stambaugh 979b4a4eb7 Revert "Move schematic symbol instance data back into symbol definition."
This reverts commit 7984e114db.
2022-09-29 15:33:23 -04:00
Wayne Stambaugh 7984e114db Move schematic symbol instance data back into symbol definition.
This change reverts the storage of all symbol instance data in the root
schematic.  This was done because it's not possible to reuse instance
data when importing from sub-sheets.

There has been a fundamental change in how sheet paths are store in the
instance data.  The root schematic UUID is always used when saving the
instance data.  To prevent file churn, the virtual root sheet UUID is set
to the root schematic UUID when loading the project.  This provides a way
to determine the project that stored the instance data.  All uses of paths
without root sheet have been expunged from the code.

The sheet instance data is still saved only in the root sheet for the
time being.  New sheet instances will be automatically assigned an page
number based on the incremental virtual sheet page number.  Sheet page
numbers will not be imported.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/12472
2022-09-29 17:47:57 +00:00
Jeff Young 536561f7b3 Move bus aliases to std::set.
This is mostly to output the aliases sorted (for ease of VCS integration),
but also because a btree will be faster than hashing on a small dataset.

Fixes https://gitlab.com/kicad/code/kicad/issues/11890
2022-09-11 19:48:08 +01:00
Wayne Stambaugh 10123d164f Fix schematic symbol initial default instance data bug.
The commit bumps the schematic file format version in order to fix the
initial symbol default instance data to the first instance of each symbol.
It also sets the initial instance data to undefined in the SCH_SYMBOL
ctor so on the first schematic save, the default instance will be set
to the first instance of the symbol.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/12190
2022-08-21 08:03:28 -04:00
Wayne Stambaugh 797827b833 Fix missing legacy value and footprint field instance data.
The legacy and s-expression (prior to version 20200828) file formats only
supported symbol unit and reference fields so the newly added value and
footprint fields must be updated from the original symbol fields.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/12226
2022-08-17 11:32:04 -04:00
Miklos Marton d30af7c164 eeschema: Add automatic rotate feature for placing global and
hierarchial labels
2022-07-05 17:02:45 +00:00
Jeff Young 2c280e83c3 Handle junctions in MarkConnections.
Fixes https://gitlab.com/kicad/code/kicad/issues/8579
2022-06-15 16:28:33 +01:00
Mike Williams 857990a883 Hierarchy: turn into a left side pane
Drop auto-closing option as well.
2022-06-02 21:56:17 +00:00
Jeff Young d5d8d36d86 Implement expanding Select Connection.
Fixes https://gitlab.com/kicad/code/kicad/issues/8579
2022-05-29 22:51:33 +01:00
Jeff Young 034b57d9c0 When reannotating keep existing prefix in most cases.
(Execption is reannotating entire schematic, in which case we reset
all of them.)

Fixes https://gitlab.com/kicad/code/kicad/issues/11379
2022-04-13 23:38:45 +01:00
Jeff Young c6a8100d46 Schematic and symbol text boxes.
Also fixes some plot bugs with arcs.

Also moves polygonization of arcs (when required) in plotting code
from 5 degrees to calculated based on ARC_HIGH_DEF.

Fixes https://gitlab.com/kicad/code/kicad/issues/5017
2022-01-28 21:38:15 +00:00
Marek Roszko c91d3e3cf9 Remove some more wxPoint 2022-01-01 14:12:20 -05:00
Marek Roszko c4c56de708 Neurotically update position wxPoint usages 2022-01-01 11:55:51 -05:00
Marek Roszko 347e03363a Convert wxPoint/wxSize starting from EDA_RECT usages 2022-01-01 11:30:33 -05:00
Jeff Young 7fc04c3cf2 Fixes for realtime connectivity being off.
Fixes https://gitlab.com/kicad/code/kicad/issues/9628
2021-11-24 13:20:44 +00:00
Jeff Young 996a5b85a6 Overhaul IsJunctionNeeded logic to support all the different cases.
Several clients were using this with different needs.  The API is
now more explicit (and there are more options under the hood).

Fixes https://gitlab.com/kicad/code/kicad/issues/9518
2021-11-04 12:57:16 +00:00
Wayne Stambaugh c61af21da8 Eeschema: don't stat files when updating title bar text.
The tests for file existence and write status perform two file stats
which cause performance issues on slow network shares.  Now the file
state is determined at load time and stored in the SCH_SCREEN object
so file access is no longer required.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/9343
2021-10-14 10:52:58 -04:00
Seth Hillbrand 6470be11c3 Add clarifying comments to EE_RTREE ordering 2021-08-20 08:49:43 -07:00
Wayne Stambaugh 04c6b79350 Eeschema: remove unused and unnecessary code.
When swapping SCH_SYMBOL objects during undo, no special processing is
required.  The SCH_PIN objects are updated when the LIB_SYMBOL objects
are swapped and the call to SCH_SCREEN::SwapSymbolLinks() didn't do
anything.
2021-08-11 14:30:29 -04:00
Jeff Young f221220fe2 Rename layer ids file.
It hasn't had anything to do with colors or visibility for some time
now.
2021-07-29 16:03:25 +01:00
Jeff Young 5a57f6ba98 Clear NEW flags after import.
Fixes https://gitlab.com/kicad/code/kicad/issues/8750
2021-07-07 20:05:50 +01:00
Wayne Stambaugh ee3eac325d Expunge the use of the word part from Eeschema code. 2021-06-15 08:32:11 -04:00
Wayne Stambaugh 71c183d7bb Rename LIB_PART to LIB_SYMBOL. 2021-06-14 07:11:17 -04:00
Wayne Stambaugh fbc135e69f Rename SCH_COMPONENT to SCH_SYMBOL. 2021-06-10 10:34:49 -04:00
luz paz f968fc8719 Fix source comment / documentation typos 2021-06-09 19:32:58 +00:00
Marek Roszko fcb21038cb Reduce some eda_item.h usage in headers 2021-06-06 11:09:06 -04:00
Wayne Stambaugh 9fcd847238 Eeschema: allow sheet file paths outside the project to be relative. 2021-05-27 14:48:22 -04:00
Jeff Young 45ba067642 Update SCH_SCREENs RTree after placing new symbol.
Fixes https://gitlab.com/kicad/code/kicad/issues/8451
2021-05-25 15:10:10 +01:00
Wayne Stambaugh df186a2049 Eeschema: fix root sheet UUID changing in project file.
This change is a bit more invasive than the description above would
suggest. UUIDs have been added to all schematics.  For now, it's only
useful to the root schematic so that the UUID in the project file does
not change every time the project file is save.  In the future, it may
be useful to store and check the schematic UUIDs against the one's saved
in the project file.

Fixes https://gitlab.com/kicad/code/kicad/issues/7763
2021-04-06 14:28:01 -04:00
Wayne Stambaugh 925b6d9387 Eeschema header housekeeping round 2. 2021-03-25 17:55:16 -04:00
Dominik Wernberger e2aa7be4b3 Added a lot of consts and refactored a few lines 2021-03-08 12:49:48 -08:00
Wayne Stambaugh 7a00e01b3e Eeschema: fix false positive library symbol changed ERC errors.
This fix required sorting all of the LIB_PART draw items to ensure
accurate comparison between the symbols stored in the schematic and the
original library symbols.  This has a noticeable impact on symbol library
load performance.  It may also cause significant changes the next time
the library is saved due to changes in the draw item sorting.  Hashing
may be a better solution here but this addressed the immediate problem.

A skeleton method SCH_SCREEN::SwapSymbolLinks() was added because there
is most likely an issue with orphaned symbols in the schematic library
symbol cache during undo/redo operations.  More testing is required to
verify this.

Fixes https://gitlab.com/kicad/code/kicad/-/issues/7263
2021-03-04 17:59:24 -05:00
Wayne Stambaugh 1786ae8773 Eeschema: use symbol nomenclature for object file naming. 2021-02-24 08:48:02 -05:00
Jeff Young d70cebcd62 Allow clicking on terminal point to finish a bus unfold.
Fixes https://gitlab.com/kicad/code/kicad/issues/7413
2021-02-07 00:31:00 +00:00
Jeff Young dfc6070178 Unify schematic file version checking with PCBNew.
This also makes sure that the user gets a warning before saving over
an older s-expr format.  While that won't always be wanted, it's now
in the infobar (like in PCBNew), so it's not too onerous.§

Fixes https://gitlab.com/kicad/code/kicad/issues/7347
2021-01-31 17:28:14 +00:00