1) Don't wait for UpdateUserInterface to build the (global) list of
layer names.
2) Report clearance resolution between a silk layer and a mask layer.
3) When writing DRC reports, include info about the violating rule.
4) Report "no relevant layers" if we fail to find anything to write
a clearance resolution report about.
Fixes https://gitlab.com/kicad/code/kicad/issues/8963
When pads having a similar name but some were not on a copper layer
(aperture pads) the net info update from old footprint to the new footprint
was incorrectly transferred. Now, only pads on copper layers are considered.
Fixes#8979https://gitlab.com/kicad/code/kicad/issues/8979
6.0 will be in the field for a long time, and the better the debugging
tools we have available the less costly it will be to maintain.
Fixes https://gitlab.com/kicad/code/kicad/issues/8961
1) improve spacing in copper zone properties.
2) improve spacing and naming in dielectric material properties.
3) clearer naming in board setup > constraints.
4) remove over-exuberant stretching in board setup > mask & paste.
They don't define a KiCad string class, so the header file name was
somewhat misleading. But the fact that they didn't match definitely
made coding more difficult.
This adds an icon to the left of the row with an error symbol if the
file can't be found or opened, and shows a tooltip over the icon with
and error string.
Fixes https://gitlab.com/kicad/code/kicad/issues/3815
Note that the dialogs which have mutliple options were not moved over
as it seems perahps not the right choice to have them save state between
sessions.
Fixes https://gitlab.com/kicad/code/kicad/issues/8762
Calling wxDialog::EndModal() directly from inside the dialog is a
potential bug if the dialog is shown in the modeless or window modal
(quasi-modal). Use the internal button events where possible and
check for the appropriate mode before calling the correct end dialog
function.
* Changed the net sorting mechanism make it similar to the 'Net Inspector' window
* Replaced the 'Show All Nets' check box with 'Hide auto-generated nets' check box
* Replace the warning label with wxInfoBar
* Removed unused controls and renamed controls where applicable
* Re-arranged the Copper Zone Properties dialog layout to improve user experience
* Minor code refactoring of DIALOG_COPPER_ZONE class
Fixes https://gitlab.com/kicad/code/kicad/-/issues/8547
The algorithm relied on the assumption that the points were
ordered anti-clockwise. When ordered in a clockwise fashion, the
result was correct but negative.
Refer to https://www.mathopenref.com/coordpolygonarea2.html
for more information.