* Move schematic wire and bus break code into schematic screen object.
* Move schematic test for dangling ends into schematic screen object.
* Remove left over debugging output in schematic screen object.
* Remove unused file eeschema/cleanup.cpp.
* Fix bug in schematic line object hit test algorithm.
* Fix a string concatenation compile error added in r2752.
* Rename class WinEDA_BasicFrame to EDA_BASE_FRAME.
* Rename class WinEDA_DrawFrame to EDA_DRAW_FRAME.
* Rename class WinEDA_DrawPanel to EDA_DRAW_PANEL.
inches and mm, the industry is crazy enough to force us with mixed
design. For example I routinely use imperial units for track size and
clearance, but drilling is strictly a metric issue...
So I added a little parser to recognize a suffix specification in the
unit text boxes... so you can put in things like:
1in (1 inch)
1" (idem)
25th (25 thou)
25mi (25 mils, the same)
6mm (6 mm, obviously)
The rules are: spaces between the number and the unit are accepted, only
the first two letters are significant.
As a bonus, it also recognize the period (.) as a decimal point
substituting it with the correct locale character (there was a wishlist
for it, IIRC). Most useful for number pad fans :D
* Moved ReturnLayerName() to static BOARD::GetDefaultLayerName() and migrated
to a Specctra DSN compatible default layer naming scheme:
Component becomes Front, Copper becomes Back.
* set_color.h: Cmp becomes Front, Cu becomes Back.
* D_PAD::DisplayInfo() changed to use actual copper layer names.
* more layer setup dialog work, moved all programmatic wxControl instantiation
into the wxFormbuilder environment, but this is fraught with danger:
wxFlexGridSizer used the tallest control to establish the row heights, so
be careful about changing control borders in the scroll panel. The vertical
size can explode since just a couple of pixels times the number of rows
is substantial. Currently I am setting a 5 pixel border only left, top, and right
but not bottom.
* Set copper layer count is back in place as a hack until I can get the enabled
layer bit map fully operational.
* Create single event handler for grid size events.
* Fix all frame windows to use new grid size event handler.
* Use offset relative to ID instead of ComboBox index to save last grid size.
* Move last grid size load/save setting into WinEDA_DrawFrame.
* Add equality and assignment operators the GRID_TYPE.
* Add current grid helper methods to BASE_SCREEN.
* Add GetPins helper to LIB_COMPONENT to replace GetNextPin where applicable.
* Add AppendMsgPanel helper to WinEDA_DrawFrame.
* Improve rounding for display of coordinates when millimeter units are selected.
* Split out application specific command IDs to prevent unnecessary rebuilding.
* Eliminate duplicate menu and tool bar command IDs.
* Split component library editor and viewer definitions to separate header files.
* More component library and document file merge code.
* A bunch of minor string readability and consistency fixes.
* Add methods to read and write project file parameters using dynamically defined list.
* Remove all global variables defined in CVPcb code.
* Dynamically define project file settings so class member variables can be used.
* Separate reading and writing application settings from project file settings.
* Make application UI objects and dialogs respect system UI font.
* Remove non-standard widget colors from CVPcb dialogs.
* Changed CVPcb object link list implementation to use wxList.
* Changed project library and path dialog to make OK button save project file instead of confusing "Save Cfg" button.
* Eliminate some duplicate file wildcard and extension definitions.
* The usual code reformatting, commenting, and spelling fixes.
caused by prematurely deleting the module editor's m_Pcb pointer, which has the same value (points to the same structure) as
g_ModuleEditor_Pcb hence should not be
deleted.
================================================================================
+eeschema
* commiting my changes to allow multiple instances of a given schematic file within
a hierarchy:
** internally, m_currentScreen has been replaced with m_currentSheet,
which is a list or 'path' of screens. The path of screens is used to
generate
a series of timestamps, which is converted to flat component reference via
a look-up
table in the schematic files.
** this means that m_currentScreen is no longer used -- use GetScreen().
** GetScreen is virtual, as some of the dialogs keep around a WinEDA_BaseScreen
pointer.
** all sub-sheets in a given schematic must have different names to generate a
meaningful netlist.