Commit Graph

11 Commits

Author SHA1 Message Date
jean-pierre charras 50743cf3ba Initial release of pl_editor, the page layout and title block editor. 2013-07-19 20:27:22 +02:00
Dick Hollenbeck 8ccf0320b4 1) Add "rules" to base of tree for copying into BZR_HOME/rules.
File "rules" has instructional text as comments near top.

2) Convert all text files in repo to LF line ending form.
   Any checkout done with "rules" in play will convert the working
   tree to native line ending, while keeping repo as LF line ending.
2013-05-25 23:36:44 -05:00
jean-pierre charras 7a5386a1a1 Minor fixes and cleanup 2013-02-26 12:25:30 +01:00
jean-pierre charras 96a77d7618 Pcbnew: Add a min width parameter to plot solder mask layers.
* If this param is set to 0, the previous behavior is used.
* Else the solder mask is plotted as polygon, with shapes near than  this min width value are  merged.
Pcbnew in nanometer version: fix a serious rounding issue due to the fact dialogs were using 4 digits for mantissa.
* This is not enough for nanometer coordinates ( 8 are needed to display a value in inches),
*  so sometimes after closing a dialog, some coordinates were modified, although no new value was entered.
Minor other bug fixed.
2012-11-06 18:58:53 +01:00
Miguel Angel Ajo 9259b21ffa Footprint wizard converts from user units to internal units back and forth, so user can type in mm or mils now 2012-07-23 00:23:17 +02:00
jean-pierre charras e96f1aeb3d Remove valeur_param(), that does not work in Kicad Nanometer 2012-04-27 16:15:11 +02:00
jean-pierre charras fa3ebc4043 Define MM_TO_IU_SCALING_FACTOR (scaling factor from mm to internal units) only in convert_to_biu.h
Other scaling factors (MILS_TO_IU_SCALING_FACTOR and DECIMILS_TO_IU_SCALING_FACTOR)
also defined only in convert_to_biu.h.
Allows different scaling value for Gerbview.
Needs more tests.
2012-04-25 21:33:24 +02:00
Wayne Stambaugh bf5802f1f7 Removal of internal units.
* Remove internal units from BASE_SCREEN and it's derivatives.
* Remove internal units from EDA_DRAW_FRAME and it's derivatives.
* Use build time code to replace internal units conversions.
* Fix scaling bug in page layout sample window that I created in my
  last commit.
2012-04-16 19:31:29 -04:00
Wayne Stambaugh 6468805c27 More internal unit improvements.
* Move all convert from user to internal units into base_units.cpp.
* Remove internal units parameters from all moved conversion functions.
* Revise all source code that calls the moved conversion functions.
* Remove internal units from all dialog text control helper classes.
2012-04-16 13:39:32 -04:00
Wayne Stambaugh 8c0dc01fdd Pcbnew nanometer internal unit fixes.
* Scale page reference border and title block, grid sizes, and zoom factors
  correctly for nanometers.
2012-04-15 21:25:26 -04:00
Wayne Stambaugh 57d75a75a8 More internal unit improvements.
* Move all convert from internal to user units functions into separate file.
* Remove internal units parameter from all moved conversion functions.
* Revise all source code that calls the moved conversion functions.
* Compile these conversion routines separately for the appropriate pcb or
  schematic internal units.
* Move internal units specific status bar update code into the appropriate
  application for updating the status bar.
* Move millimeter user units rounding function to common.cpp.
2012-04-13 14:51:24 -04:00