The new behavior is to only expand to the first child of the root sheet
level. On very complex hierarchies, this makes the navigator far more
useful.
Do not update schematic hierarchy navigator on every edit. Now only
sheet changes will trigger a rebuild of the tree.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/16371
The IO_RELEASER is a thin-wrapper around a std::unique_ptr, but done
this way to allow easier addition of a custom deleter in the future if
something needs to call back into the IO_MGR.
Pasting from the clipboard when copying from another project can leave
sheet instance information that is not valid for the current project.
This change prunes all sheet instance information that is not relevant
to the current project. It also prunes invalid paths created by pasting
sheets from different paths in the same project.
produces a crash when the library links are updated, and a power symbol is not found
in any loaded library.
Add also an option to export all symbols or all not pwer symbols
Fixes#16229https://gitlab.com/kicad/code/kicad/-/issues/
The paste code creates invalid KIID_PATH objects with a zero length. All
paths must include the root KIID at a minimum. Code was added to prune
the invalid paths and some defensive code was adding to the formatter to
prevent the crash in case there are other paths where someone generates
a zero length path.
Pruning orphaned instance data does not work when loading schematics prior
to version 7 because the paths did not include the root sheet UUID. Once
the file is saved to V7 or later, the next load will prune any orphaned or
invalid instance data for the current project.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/16245
It appears that in our zeal to prevent file changes when saving shared
schematics, we (I) clobbered saving relative symbol instance data paths
to the clipboard. This has be restored along with setting the correct
symbol unit for relative clipboard paths.
Fixed a serious issue with KIID_PATH::MakeRelativeTo() where the original
path was not restored when the incremental KIID object test fails. This
also included a minor optimization using the actual KIID object for
comparison instead of converting it to a string and then comparing the
string.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/15981
[CHANGED] Bus highlight tool now supports toggling between highlighting
only the bus objects and highlighting the bus and all of the
bus member objects.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/15388
This is required to keep selected and brightened state across undo.
It's also probably required for things like IS_SHOWN_AS_BITMAP and
possibly ENTERED. FWIW, most BOARD_ITEMs do a straight swap, including
the temp and edit flags. But that seems like a risky change....
Also removes SyncView() call from Undo/Redo as that does a MODEL_RELOAD
which clears the selection.
Note that "immediate" doesn't mean quite the same thing: while it will
enter the tool immediately, it won't necessarily finish the tool during
the call if the tool has an event loop. So for something like Rotate
"immediate" and "synchronous" have the same behaviour, but for something
like Move they do not.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/15085
Using a boolean argument just leads to a lot of trailing booleans in the
function calls and is not user friendly. Instead, introduce PostAction()
to send an action that runs after the coroutine (equivalent to passing
false or the default argument), and leave RunAction as the immediate
execution function.
Note: This changes the net highlight tool behavior. When clicking on an
already highlighted net, the net highlighting is no longer toggled
off. This prevents the net navigator panel from being cleared.
- Expand tree and highlight object selected with net highlight tool.
- Expand tree and highlight object that are currently highlighted with the
selection tool.
- Use more descriptive object text rather than menu entry text for tree
strings.
- Rebuild tree on unit changes.
[ADDED]: A panel to the schematic editor that allows quick access to all
of the items connected to the currently highlighted net.
This is an initial swag at implementing a full net navigator feature. For
now it only shows the currently highlighted net nodes. The incremental
net list advanced setting must be enabled in order to use this feature due
to performance reasons. There are still some issues with saving the panel
position which will be addressed in the future.
Initial code for serializing wxAuiPaneInfo settings to and from JSON have
be implemented.
SCH_CONNECTION objects are temporary and can become stale any time the
connectivity is updated. Keeping them around to reference later is a
bad idea. Even if the object pointer is still valid in an SCH_ITEM in
the undo/redo buffers, comparing the pointer against another pointer as
a test to see if they are the same connection is not valid. Saving the
connection name is safe and ensures the connection is the same even if
the pointers differ.
The undo command has accreted a number of things over the years. This
prunes back the changes to the minimum required number and correctly
orders the actions
Fixes https://gitlab.com/kicad/code/kicad/issues/14661