RS274X Gerber files using only regions (polygons) can be valid, and are not old RS274D files
Now a warning is raised only if there are some missing D codes definitions
(RS274D file or broken RS274X file)
Remove unused var and add comments
Fixes: lp:1850821
https://bugs.launchpad.net/kicad/+bug/1850821
Previously, the M and G00, G01, G02 and G03 commands were read, but nothing was actually done.
The current support is a bit rough, but it allows reading some drill files with routing commands.
The main issue is the fact Excellon files have no coordinate fine format definition.
Only the units are defined.
Units are floating point numbers or integer numbers.
Integer numbers can be defined as 3.3 or 2.4 numbers (mm/inches)
However some files (altium drill files for instance) use an other notation.
This fix is a workaround to accept 2.x (inch) or 3.x (mm) notations.
Fixes: lp:1754121
https://bugs.launchpad.net/kicad/+bug/1754121
Fixes: lp:1782053
https://bugs.launchpad.net/kicad/+bug/1782053
A structured comment is a comment line starting by "G04 #@! " and in fact containing
a X2 attribute. It is used to create Gerber files contianing X2 metadata, but compatible
with X1 file format