1) Add highlighting to simProbe and simTune tools.
2) Probe tool should accept wires and pins, not wires and components.
3) Give simulator window a flat look to match rest of Kicad.
4) Collapse whitespace out of simulator window.
5) Add some error messages.
6) Add some whitespace to simulation setting dialog.
When removing a junction, we need to keep the next pointer for deleted
item, marking them with a flag until committed.
Fixes: lp:1837398
* https://bugs.launchpad.net/kicad/+bug/1837398
(cherry picked from commit 4363e6a213)
When selecting items where the reference point is off-screen, GTK
would default the cursor to jump to the bottom of the screen.
Fixes: lp:1838843
* https://bugs.launchpad.net/kicad/+bug/1838843
While we do not generate these arcs internally, some external tools
generate arcs that are technically valid but display correctly only
because of an oddity in the degeneracy mapping.
Fixes: lp:1838557
* https://bugs.launchpad.net/kicad/+bug/1838557
(cherry picked from commit cf949609b2)
Check for symbol libraries that somehow ended up in the project file
after remapping occurred and remove all of them to prevent potentially
broken symbol library links.
Add nagware dialog to warn the user and a checkbox to never show the
dialog again.
Fixes lp:1838185
https://bugs.launchpad.net/kicad/+bug/1838185
Images have a scale factor and this factor was taken in account twice
For image having a scale factor not equal to 1.0, the bounding box was too big (or too small)
Remove an existing sheet from the current page that requires a schematic
load from file to prevent a corrupt screen list from causing a segfault.
Merge the edit sheet file loading with the append schematic code since
they are functionally the same. This allows the sheet edit code to
take advantage of all of the added broken symbol library links added in
the recent append schematic fixes.
Fixes lp:1835841
https://bugs.launchpad.net/kicad/+bug/1835841
Also rewrites the PCBNew Find dialog to make use of the above, including:
1) searching in user-defined footprint fields
2) searching in pcb text
3) a history list in the search popup
4) case sensitive searching
5) word sensitive searching
6) the ability to turn wildcard searching on/off
7) better placement of the result when the dialog obscures part of the
window
Fixes: lp:1838006
* https://bugs.launchpad.net/kicad/+bug/1838006
The problem is that wxEVT_CHAR_HOOK doesn’t do the key translation
properly. wxEVT_CHAR does, but we only get to that if we skip the
event at the end of the tool’s event processing loop, which most tools
don’t do. (Selection tools, point editors, pickers, and a couple of
others do skip, which is probably why this didn’t get reported earlier.)
I played around with a couple of ways to fix wxEVT_CHAR_HOOK. Most of
them don’t work, and the few egregious hacks I tried weren't cross-
platform.
So I’m changing it so that most tools now skip at the end of their
event loops. I left out a couple that I felt were high risk (length
tuning, for instance). But there’s still enough risk that I’m 100%
sure it will break something, I just haven’t a clue what.
Fixes: lp:1836903
* https://bugs.launchpad.net/kicad/+bug/1836903
The point editor expects rectangles with a height and width > 0.
Previously, this constraint did not exist,
so some LIB_RECTANGLE graphic items can create issues when trying to move a corner.
Now, the LIB_RECTANGLE graphic item is normalized before trying to move a corner.
This fixes the last suffix that was missed by 168fa09f5. The schematic
backup files should have the suffix .sch-bak to distinguish from
.kicad_pcb-bak or other backups.
(cherry picked from commit b6fe4ff637)
Previously, for instance after modifying preferences or language,
they were rebuilt but the tools state was not set due to a missing call to SyncToolbars() after rebuilding.
Do not add cache library from another project to old library list. This
is wrong and can cause all kinds of symbol library linking issues. It's
better to force the user to fix broken symbol library links than the false
security of using multiple cache libraries.
Use correct paths when appending schematic outside of the current project
path when hierarchical sheets are appended. If the path can be relative,
give the user the option to use either relative or absolute paths.
Do not change symbol library names in schematics appended from a source
outside the current project. This will almost ensure the symbol library
links will be broken in the source project.
When the appended schematic is from another project, attempt to check all
of the possible combinations of symbol library table importing that could
cause broken symbol library links and give the user the option of canceling
the append operation or live with the possibility that there may be broken
symbol library links.
When the append schematic is in the current project path but not part of
the schematic, check to see if there are any library nicknames that do
no exist in the project symbol library table and give the user a chance
to cancel the append process.
This reverts commit eadf6d93bc.
because the issue with net names containing '/' is not actually inside the netlist.
This commit eadf creates issues with ngspice 2.8 and older, and do not fix anything in ngspice