When activate the new symbol placement, the mouse cursor is outside the canvas.
Therefore a autopan was started and not so easy to stop.
Now the mouse cursor (and the graphic cursor) are moved to a better location inside the canvas.
Fixes#8156https://gitlab.com/kicad/code/kicad/issues/8156
1) Don't reset value when name changes
2) Don't fire events when initialising dialog
3) Make sure when symbol is saved back to schematic that only current
instance has its ref updated, but that all instances have their other
fields updated.
4) When saving symbol back to board always use the fields from the
editor and not the (alias-specific) ones from the library.
Fixes https://gitlab.com/kicad/code/kicad/issues/8159
We've been doing this for some time to wires that are attached to
the moving block (and therefore have the other end anchored). However
we also need to apply it when dragging a single end of a wire.
Fixes https://gitlab.com/kicad/code/kicad/issues/7807
This change is a bit more invasive than the description above would
suggest. UUIDs have been added to all schematics. For now, it's only
useful to the root schematic so that the UUID in the project file does
not change every time the project file is save. In the future, it may
be useful to store and check the schematic UUIDs against the one's saved
in the project file.
Fixes https://gitlab.com/kicad/code/kicad/issues/7763
The native cursor must be set on the GAL canvas wx object,
not its frame (otherwise on GTK the cursor is only set
when we get a request for it from the WM and not immediately).
Fixes https://gitlab.com/kicad/code/kicad/issues/6421
This is under the supposition that we can't set the column widths
on some Mac instances because the host controls haven't yet been
created. This is primarily conjecture based on looking at things
that have the *possibility* of going wrong. Why this only happens
in some installs is beyond me.
Fixes https://gitlab.com/kicad/code/kicad/issues/5479
If a field name is already in use, try to rename the new field name
(adding the suffix "_1" or "_2" or ... )
This is especially critical when a non mandatory field has the same name as
a mandatory field (was crashing before)
Fixes#8081https://gitlab.com/kicad/code/kicad/issues/8081
After commit 9535153f9e there were no more IDs inside the legacy ID
system. Therefore the entire system for dispatching and looking up
the legacy ideas and handling those events can now be removed and
the tool dispatcher simplified (it no longer needs to know about
the ACTIONS class).
The new s-expression format embeds the library within the file
so there should be no connectivity issues (unless they were present
in the original design).
This fixes a potential issue with EAGLE imported schematics.
The previous assumption was that a part definition would always hold
the information about the symbol. However some designs have symbol
instances that refer to a different symbol definition than that
specified in the part.
Fixes https://gitlab.com/kicad/code/kicad/-/issues/7808