Don't open-code knockout text shape generation in several different
places.
Make sure triangulated knockout text gets clearance added when
specified.
Collapse duplicated footprint text item plot routine (they're no
longer any different from plotting pcb text items).
(cherry picked from commit c71cf21e2f)
CHANGED: The text variable ${SHEETNAME} now always represents the name of the
sheet when used anywhere in the schematic editor, including the title block
ADDED: A new text variable ${SHEETPATH} which is replaced with the path to the
current sheet - e.g. "/Sheet 1/Sheet 2".
To ensure backward compatibility, the default drawing sheet now uses
${SHEETPATH}. Custom drawing sheets will need to be manually edited.
We only need one bottom to top layer sequence definition.
Plot a sequence of layer IDs (LSEQ) in the order of the sequence.
Add helper method to layer set (LSET) to create a sequence of layer IDs
using another sequence for ordering.
1) Don't plot all footprint texts for each footprint graphic item.
2) Enforce min web thickness around board shapes and board text.
3) Enforce min web thickness around footprint shapes
4) Correctly handle multi-layer zones.
(1) and (4) will get cherry-picked back to 6.0, so after rebasing
won't actually appear in this changelist anymore....
CHANGED: Settings are now stored in versioned sub-directories
ADDED: First-run dialog for migrating settings from a previous version
CHANGED: Settings are now stored as JSON files instead of wxConfig-style INI files
CHANGED: Color settings are now all stored in a separate settings file
CHANGED: The symbol editor and footprint editor now have their own settings files
CHANGED: Color settings are no longer exposed through BOARD object
CHANGED: Page layout editor now uses Eeschema's color scheme
Settings are now managed through a central SETTINGS_MANAGER held by PGM_BASE.
Existing settings will be migrated from the wxConfig format on first run of each application.
Per-application settings are now stored in one class for each application.
* Split up the thirdparty code into the thirdparty folder (#3637)
* Create a new kimath static library containing all the math functions
This is part of cleaning the build system for #1906.
eeschema now supports arbitrary colors for all object types, and
pcbnew does in GAL canvas. When switching from GAL to legacy canvas,
pcbnew will convert colors to the nearest legacy color.
This option is not yet activated because the net attributes are not yet fully fixed by Ucamco, in Gerber file format specifications.
(To activate it, see dialog_plot.cpp, line 43)
Pcbnew: Plot files: for copper layers, create suffix from user copper layer names instead of default copper layer names, like in last stable Kicad version (bzr 4022), to build the plot files filenames.
Better test of illegal chars in plot filename, both in plot dialog and functions aclled by Python scripts.
Fix a Plotcontroller issue to make SetUseGerberExtensions() work as expected from Python scripts ( from Henner Zeller'patch with a fix to be sure it works properly from a Python script)
Note also using Protel Gerber Extensions is now a bad practice, because the official Gerber extension is .gbr since X2 Gerber version. But some users still use them)