Commit Graph

21 Commits

Author SHA1 Message Date
Simon Richter 59c81976dc Explicitly mark overriding functions. 2016-09-24 14:53:15 -04:00
Maciej Suminski c4be379b31 Modified properties dialog to take advantage of BOARD_COMMIT class. 2016-09-12 11:50:06 +02:00
Maciej Suminski 1dd43d1d98 Unified undo buffer handling code for PCB & module editor.
Replaced UR_MODEDIT with UR_CHANGED.
2016-09-12 11:50:06 +02:00
Chris Pavlina 36b53a50e9 Fix signedness in a couple comparisons (warning suppression) 2016-04-12 19:18:42 -04:00
Chris Pavlina 9e3fd5b762 Nuke 0.1deg units in DIALOG_GRAPHIC_ITEM_PROPERTIES 2016-04-11 10:27:32 -04:00
Blair Bonnett 07db7c8d29 Prevent Pcbnew edit graphics property dialog from excepting zero length objects. (fixes lp:1392117) 2015-02-06 16:49:40 -05:00
Wayne Stambaugh 86b39ca3c0 More missing source license fixes. 2014-10-27 10:14:39 -04:00
Lorenzo Marcantonio 1247264458 Added layer change to the module text dialog (both user text and reference/value)
Since reference and value are not anymore always on silk changed the label on the corresponding options in the plot dialog
The 'proper Gerber extensions' was renamed in dialog as 'Protel Gerberl extensions': I don't know if it was a typo/misunderstanding or what but the proper extension is gbr; the set of alternative extensions seems to be the one used by Protel/Altium.
2014-09-13 08:15:16 +02:00
Dick Hollenbeck ad750defb6 LAYER_ID work 2014-06-29 08:05:51 -05:00
Dick Hollenbeck 4578ea8b9e 1) Add 32 Cu Layers.
2) Change from legacy Cu stack to counting down from top=(F_Cu or 0).
   The old Cu stack required knowing the count of Cu layers to make
   sense of the layer number when converting to many exported file types.
   The new Cu stack is more commonly used, although ours still gives
   B_Cu a fixed number.
3) Introduce class LSET and enum LAYER_ID.
4) Change *.kicad_pcb file format version to 4 from 3.
5) Change fixed names Inner1_Cu-Inner14_Cu to In1_Cu-In30_Cu and their
   meanings are typically flipped.
6) Moved the #define LAYER_N_* stuff into legacy_plugin.cpp where they
   can die a quiet death, and switch to enum LAYER_ID symbols throughout.
7) Removed the LEGACY_PLUGIN::Save() and FootprintSave() functions.
   You will need to convert to the format immediately, *.kicad_pcb and
   *.kicad_mod (=pretty) since legacy format was never going to know
   about 32 Cu layers and additional technical layers and the reversed Cu
   stack.
2014-06-24 11:17:18 -05:00
Dick Hollenbeck 2c67c3ff80 * KIWAY Milestone A): Make major modules into DLL/DSOs.
!   The initial testing of this commit should be done using a Debug build so that
    all the wxASSERT()s are enabled.  Also, be sure and keep enabled the
    USE_KIWAY_DLLs option.  The tree won't likely build without it.  Turning it
    off is senseless anyways.  If you want stable code, go back to a prior version,
    the one tagged with "stable".

*   Relocate all functionality out of the wxApp derivative into more finely
    targeted purposes:
    a) DLL/DSO specific
    b) PROJECT specific
    c) EXE or process specific
    d) configuration file specific data
    e) configuration file manipulations functions.

    All of this functionality was blended into an extremely large wxApp derivative
    and that was incompatible with the desire to support multiple concurrently
    loaded DLL/DSO's ("KIFACE")s and multiple concurrently open projects.
    An amazing amount of organization come from simply sorting each bit of
    functionality into the proper box.

*   Switch to wxConfigBase from wxConfig everywhere except instantiation.
*   Add classes KIWAY, KIFACE, KIFACE_I, SEARCH_STACK, PGM_BASE, PGM_KICAD,
    PGM_SINGLE_TOP,
*   Remove "Return" prefix on many function names.
*   Remove obvious comments from CMakeLists.txt files, and from else() and endif()s.
*   Fix building boost for use in a DSO on linux.
*   Remove some of the assumptions in the CMakeLists.txt files that windows had
    to be the host platform when building windows binaries.
*   Reduce the number of wxStrings being constructed at program load time via
    static construction.
*   Pass wxConfigBase* to all SaveSettings() and LoadSettings() functions so that
    these functions are useful even when the wxConfigBase comes from another
    source, as is the case in the KICAD_MANAGER_FRAME.
*   Move the setting of the KIPRJMOD environment variable into class PROJECT,
    so that it can be moved into a project variable soon, and out of FP_LIB_TABLE.
*   Add the KIWAY_PLAYER which is associated with a particular PROJECT, and all
    its child wxFrames and wxDialogs now have a Kiway() member function which
    returns a KIWAY& that that window tree branch is in support of.  This is like
    wxWindows DNA in that child windows get this member with proper value at time
    of construction.
*   Anticipate some of the needs for milestones B) and C) and make code
    adjustments now in an effort to reduce work in those milestones.
*   No testing has been done for python scripting, since milestone C) has that
    being largely reworked and re-thought-out.
2014-03-19 19:42:08 -05:00
jean-pierre charras ede208f3cb Pcbnew: use pcb layer box selector in dialog graphic item properties and pcb text properties. 2013-09-03 14:48:38 +02:00
Lorenzo Marcantonio d00c83cde9 Migrated the interfaces accepting angles to the double type
The plan goes like this:
- eeschema still uses int in decidegrees
- all the other things internally use double in decidegrees (or radians
  in temporaries)
- in pcbnew UI the unit is *still* int in decidegrees

The idea is to have better precision everywhere while keeping the user with int i
angles. Hopefully, if a fractional angle doesn't come in from the outside, everything
should *look* like an integer angle (unless I forgot something and it broke)

When the time comes, simply updating the UI for allowing doubles from the user should
be enough to get arbitrary angles in pcbnew.
2013-05-05 09:17:48 +02:00
Lorenzo Marcantonio b525e3be55 Factored out text anchor drawing
More layer classification cleanup
2013-04-09 18:00:46 +02:00
Lorenzo Marcantonio 9fd79dfa91 Implemented the LAYER_NUM typedef (LAYER was already taken as a class name...) to represent a layer number. 2013-03-31 15:27:46 +02:00
Wayne Stambaugh f8a56d446f Base object decoupling improvements.
* Improve MSG_PANEL_ITEM to handle message panel information.
* Create containers for passing message panel items between objects and
  the message panel.
* Rename EDA_ITEM::DisplayInfo to EDA_ITEM::GetMsgPanelInfo.
* Remove all direct manipulation of EDA_DRAW_FRAME from all objects derived
  from EDA_ITEM.
2013-01-12 12:32:24 -05:00
Lorenzo Marcantonio 7d154606be Substituted the few remaining uses of long instead of time_t 2012-09-05 14:13:33 +02:00
Wayne Stambaugh 6468805c27 More internal unit improvements.
* Move all convert from user to internal units into base_units.cpp.
* Remove internal units parameters from all moved conversion functions.
* Revise all source code that calls the moved conversion functions.
* Remove internal units from all dialog text control helper classes.
2012-04-16 13:39:32 -04:00
Wayne Stambaugh 57d75a75a8 More internal unit improvements.
* Move all convert from internal to user units functions into separate file.
* Remove internal units parameter from all moved conversion functions.
* Revise all source code that calls the moved conversion functions.
* Compile these conversion routines separately for the appropriate pcb or
  schematic internal units.
* Move internal units specific status bar update code into the appropriate
  application for updating the status bar.
* Move millimeter user units rounding function to common.cpp.
2012-04-13 14:51:24 -04:00
jean-pierre charras 909c2a6051 Dialog exit: better icon.
Pcbnew:
 * graphic_item_properties_base.fbp * dialog pad edit: make some strings more easier to translate.
 * global pad edition: fix a bug that change pad position instead of pad size (round pas only).
Eeschema:
 * fix a bug: new created wires were not alwaes shows until the screen was redrawn.
2012-03-09 19:58:58 +01:00
jean-pierre charras 197ace9e44 Modedit: add dialog to edit footprint body items. Fix also minor issues about footprint body items edition. 2012-02-12 20:39:37 +01:00