SCH_SCREEN::UpdateSymbolLinks() should only be called when working with
the legacy schematic file format. Add schematic symbol library symbol
links should be set using SCH_COMPONENT::SetLibSymbol() which updates
the symbol link and pin map accordingly.
Change the schematic symbol LIB_ID edit dialog to properly use the new
SCH_COMPONENT::SetLibSymbol() function.
Use flattened (root) library symbols to prevent broken library symbols
in schematic files.
Remove the edited symbol from screen before making changes to the symbol
to prevent potential orphaned symbol libraries being saved in schematic
file.
Add some defensive programming to let developers know that an invalid
library symbol link was used when calling SCH_COMPONENT::SetLibSymbol().
There has been a long standing (since the beginning of the project?)
issue with sharing schematics between projects. It has been somewhat
supported for complex hierarchies (a sheet shared multiple times in a
single design) but it has not been well supported for simple hierarchies
(the symbol references cannot be changed in the shared schematic). This
issue has been resolved by moving all of the symbol instance sheet paths
from the symbol definitions in the all of the project files and save all
symbol path instances in the root sheet. This ensures that orphaned
symbol instance paths do not accumulate in shared schematic files and
that designs that reuse schematic in simple hierarchies can how have
different references. It also allows the root schematic from one project
to be uses as a sub-sheet in another project.
When legacy schematics are loaded, all sheet and symbol UUIDs are
converted from time stamps to true UUIDs. This is done to ensure there
are no sheet path instance clashes between projects. That being said,
there are no checks for this. It is assumed that the probability of
UUID clashes is so low that it doesn't make sense to test for them.
This is a very large and potentially disruptive change so this will be an
unusually long and detailed commit message.
The new file formats are now the default in both the schematic and symbol
library editors. Existing symbol libraries will be saved in their current
format until new features are added to library symbols. Once this happens,
both the legacy schematic and symbol file formats will be no longer be
savable and existing libraries will have to be converted. Saving to the
legacy file formats is still available for round robin testing and should
not be used for normal editing.
When loading the legacy schematic file, it is imperative that the schematic
library symbols are rescued and/or remapped to valid library identifiers.
Otherwise, there will be no way to link to the original library symbol and
the user will be required manually set the library identifier. The cached
symbol will be saved in the schematic file so the last library symbol in
the cache will still be used but there will be no way to update it from the
original library.
The next save after loading a legacy schematic file will be converted to
the s-expression file format. Schematics with hierarchical sheets will
automatically have all sheet file name extensions changed to .kicad_sym
and saved to the new format as well.
Appending schematics requires that the schematic to append has already been
converted to the new file format. This is required to ensure that library
symbols are guaranteed to be valid for the appended schematic.
The schematic symbol library symbol link resolution has been moved out of
the SCH_COMPONENT object and move into the SCH_SCREEN object that owns the
symbol. This was done to ensure that there is a single place where the
library symbol links get resolved rather than the dozen or so different
code paths that previously existed. It also removes the necessity of the
SCH_COMPONENT object of requiring any knowledge of the symbol library table
and/or the cache library.
When opening an s-expression schematic, the legacy cache library is not
loaded so any library symbols not rescued cannot be loaded. Broken library
symbol links will have to be manually resolved by adding the cache library
to the symbol library table and changing the links in the schematic symbol.
Now that the library symbols are embedded in the schematic file, the
SCH_SCREEN object maintains the list of library symbols for the schematic
automatically. No external manipulation of this library cache should ever
occur.
ADDED: S-expression schematic and symbol library file formats.
Some items (tracks and footprint graphic items) when reading were added in reverse order
of the initial file, creating useless differences and breaking source comparisons.
Also fixes a bug where a bunch of eeschema settings weren't getting
loaded because it looked like they were larger than the max value
(which wasn't being scaled from mils to internal units).
Fixes https://gitlab.com/kicad/code/kicad/issues/2089
In Eeschema, texts are expected to have the same size X and size Y.
So we cannot set 2 different values for X and Y pin size:
- only size X is saved in file
- 2 different values for X and Y create bad look for pin + associated graphic symbol
Allowing separte values need a file format change *and* a code change.
These panels must have the wxTreeBook as parent to receive mouse and key events.
They previously have the dialog itself, but it does not work on any OS.
(the dialog was reactivated by calling Raise(), but this is not enough: Show()
must be called also, at least on Windows).
Fix also a minor wxWidgets alert in ERC dialog.
Fixes#4171https://gitlab.com/kicad/code/kicad/issues/4171
When editing a sheet properties, the dialog always thinks the sheet filename is changed.
It creates serious issues, like duplicating all items in sheet, because the code try to
again import the existing sheet file content.
The temporary fix does not import the existing sheet file content if the
filename is not modified.
This is a very partial fix, because there are many other issues in this dialog
The code that checked for pin conflicts to determine if a symbol needed
rescued did not check either the pin convert setting so it was possible
for a pin from the other convert on symbols that do not have identical
units to appear to not have a pin conflict. Add tests for pin unit and
convert setting to prevent that from breaking the comparison. This must
have always been broken.
Fix the symbol preview widget to prevent drawing all symbols on top of
each other (if we need to do this the code will have to be revised) and
also show the convert if valid.
Fix broken symbol cache library when saving alias symbols.
Fixes https://gitlab.com/kicad/code/kicad/issues/3879
It looks good, but non-mandatory fields have an ID of -1, so it
doesn't actually work. Some places got around this by converting
the ID to unsigned, but this just hides the real issue from
unsuspecting coders.
Fixes https://gitlab.com/kicad/code/kicad/issues/4140
Please note that the symbol cache is not embedded in the schematic file
to allow for round robin testing with the existing file format. Once
the parser round robin testing is complete, the symbol cache will be
embedded in the schematic file.
Includes improvements to Update PCB from Schematic dialog and
corresponding changes to Symbol Properties, Sheet Properties and
Footprint Properties.
Fixes https://gitlab.com/kicad/code/kicad/issues/4012
Replace SEVERITY_ERROR by RPT_SEVERITY_ERROR to avoid collision with a system definition.
Replace other SEVERITY_XXX by RPT_SEVERITY_XX for consistency.
Fix compil warnings and some other compil issues.
This implements all existing symbol library object support and the ability
to save and load symbol library files between file formats for round robin
testing.
CHANGED: Settings are now stored in versioned sub-directories
ADDED: First-run dialog for migrating settings from a previous version
CHANGED: Settings are now stored as JSON files instead of wxConfig-style INI files
CHANGED: Color settings are now all stored in a separate settings file
CHANGED: The symbol editor and footprint editor now have their own settings files
CHANGED: Color settings are no longer exposed through BOARD object
CHANGED: Page layout editor now uses Eeschema's color scheme
Settings are now managed through a central SETTINGS_MANAGER held by PGM_BASE.
Existing settings will be migrated from the wxConfig format on first run of each application.
Per-application settings are now stored in one class for each application.
When searching for fields, the code was sometimes comparing translated and not translated names.
This is an issue for mandatory fields, in non English languages.
Translated field names should be used only in messages.
When adding a .pretty library, if the actual .pretty folder were
selected then no folder would be added to the list of libraries.
This led to an assert when normalizing paths, and the library
not being added.
Add also a comment in common.cpp about using wxLocale instead of setlocale.
DIALOG_UPDATE_FIELDS has issues in non English languages, due to its design.
The fix for mandatory fields is only a partial fix that avoid major issues.
Previously, OnModify() was called for a lot of items, even when not modified.
For large schematics, the calculation time was unreasonable ( several minutes)
It is now called only a few times.
Shared sheets can create issues in a complex hierarchy.
This is not related to sharing sheets between projects.
(Sharing sheets between projects is not supported by Kicad)
These help files are created from the .md source files and contain I18n strings,
but do not exist if kicad is not built from sources.
However they are needed by translators.
ADDED: Back annotation algorithm,
eeschema back annotation dialog
CHANGED: added some minor helper methods to SCH_REFERENCE_LIST and SCH_REFERENCE,
split SCH_REFERENCE_LIST::CheckAnnotation on 2 parts to reuse code
When opening the symbol editor without loading the schematic editor the
default text size setting is not loaded and was defaulting to the old mils
setting. Convert the default text size to internal units in case the
symbol editor is launched first.
Set default line, bus, and selection highlight width to internal units.
Change new symbol dialog pin position offset control from a spin control
to a text control so the unit binder object can handle converting to and
from internal units.
Fixes#3802https://gitlab.com/kicad/code/kicad/issues/3802
Scope: NETLIST_ITEM, CONNECTION_TYPE, ELECTRICAL_PINTYPE,
NET_CONNECTION, NETLIST_ITEM, GRAPHIC_PINSHAPE
Note, the pin type enum had PT_ added to the front to prevent
shadowing of the INPUT symbol on msys2 (see discussion at
c17c9960d8)
This also removes vector cover types which do nothing except obfuscate
the underlying implementation.
Mainly changes SCH_SHEET_PINS and CONFIG_PARAM_ARRAY (which will soon
be replaced by Jon's new stuff).
This moves EESchema DLIST structures to rtree. These changes are more
fundamental than the pcbnew changes from 9163ac543888c01d11d1877d7c1
and 961b22d60 as eeschema operations were more dependent on passing
drawing list references around with SCH_ITEM* objects.
For legacy reasons, it stored left and right "spin" as flipped integers in the file format.
But the code handled the flip in multiple locations rather than just doing it on file io.
This change unifies the internal code and does the mapping in the file I/O.
* Split up the thirdparty code into the thirdparty folder (#3637)
* Create a new kimath static library containing all the math functions
This is part of cleaning the build system for #1906.
ADD: User can now decide to keep the hierarchy navigator open while working
on a schematic.
This behavior can be configured in eeschema->preferences->eeschema->Editing options.
Change default text size and anchor positions back to mils. Internal
units need to be converted at the source, otherwise the size will get
converted twice in the schematic editor configuration code which will
result in the default text size being off by the conversion factor.
Fixes#3730https://gitlab.com/kicad/code/kicad/issues/3730#
Derived symbols were causing the symbol properties grid to assume that
the reference could not be edited because derived symbols inherit the
reference from the parent symbol. The flattened symbols in the schematic
still have the parent set which cause the issue. Clearing the parent of
the flattened symbol resolves the issue.
Fix a minor bug in the symbol information of derived symbols show in the
symbol chooser dialog.
Fixes#3723https://gitlab.com/kicad/code/kicad/issues/3723
ADDED: a config option to select (when clicking on a pin) the parent symbol
or only the pin.
Previously, when cliking on a pin, the parent symbol was selected.
Allowing the pin selection is mandatory in cross probing, and to display the pin
characteristics in some cases, for instance if a pin is flagged by the ERC tooL.
There is no need to create a new root symbol and re-parent all derived
symbols when renaming a root symbol. Just rename the buffered root
symbol.
Test for duplicate symbol names when validating the properties dialog
information to prevent broken symbol pointers.
Fix a field drawing bug when editing derived symbols.
Fix bug to insure duplicate symbol names cannot exist in a library.
Fixes kicad/code/kicad#3654
Fixes kicad/code/kicad#3672
The library manager update part function was orphaning the root symbol
of derived symbols when the root symbol was edited. Re-parent the
inherited symbols when updating a root symbol.
Update the mandatory field attributes whenever the parent is set for
derived parts. This will show the fields with the correct attributes
in the symbol editor and viewer.
Using std::unique_ptr to hold the current symbols was deleting the
pointer on symbol selection changes causing the pointer in the library
manager buffer to be stale in some cases. Revert back to using a
simple pointer and manual clean up as required.
Prevent derived symbols from being saved to a different library to
prevent orphaned symbols.
Fixes kicad/code/kicad#3649
ADDED new option to set selection highlight thickness.
Also change selection shadow width constants to
make the selection thickness change less drastically
with the zoom level.
This change completely removes the LIB_ALIAS design pattern an replaces
it by allowing LIB_PART objects to inherit from other LIB_PART objects.
The initial implementation only allows for single inheritance and only
supports the mandatory fields in the derived part because that is all
that the current symbol library file format will support. Once the new
file format is implemented and saving to the old file format is deprecated,
more complex inheritance will be added. The LIB_ALIAS information saved
in the document files was move into the LIB_PART object. This change
impacts virtually every part of the schematic and symbol library editor
code so this commit message is woefully incomplete.
REMOVE: Removed the symbol aliases concept from the schematic and symbol
editors and the symbol viewer.
NEW: Replace the symbol alias concept with simple inheritance that allows
a library symbol to be derived from another library symbol.
It happens when the spice library model shown in dialog is a large file.
Looks like the wxTextCtrl used to displays the library content
creates the crash ( GKT bug?) for large texts.
The fix is to replace this wxTextCtrlt by a wxStyledTextCtrl.
It has advantages (does not crash... and much faster display) and
inconvenients (cannot disable editing).
Fixes: lp:1853161
https://bugs.launchpad.net/kicad/+bug/1853161
The sort routine requires the value to be true with a is strictly lower
than b. But just inverting the '<' doesn't yield strictly lower, it
includes '>='. This causes items to jump in the list.
NEW: A text entry allows adding signals by name. This includes vectors
not in the signal list, which is useful for plotting calculated vectors
like `let AB=V(a)*V(b)`. It's also a faster way to add a signal if you
know its name already.
Fixes: lp:1851373
* https://bugs.launchpad.net/kicad/+bug/1851373
The new connectivity algorithm had a tendency to cleanup
globally, but that could insert undo records from other sheets
into the current screen's undo stack. Needless to say, this
was a recipie for segfaults.
Fixes: lp:1846247
* https://bugs.launchpad.net/kicad/+bug/1846247
Note that since the markup might exist for other reasons, it has
to be turned on with a preference setting. (It goes through a set
of bitflags so the same architecture can be used for other markup
structures that we might want to support in the future.)
Note also that this is more about engineering nomenclature than
visual formatting. In that respect it's more similar to overbar
than italic or bold.
When placing a new component in the schematic, this allows the user to
iterate through all units in the selected component without re-opening
the choose part dialog. It also allows the optional addition of
multiple copies of the same component to be placed in the schematic.
Fixes: lp:1806217
* https://bugs.launchpad.net/kicad/+bug/1806217
This makes the pcbnew multiline text editor natively accept tabs in the
same manner as eeschema and extracts key handling routines to the shim
to allow undo/redo.
Also allows Ctrl-Y under Linux in addition to other platforms. While
not as popular as Ctrl-Shift-Z, it is utilized for Redo in some contexts
When editing symbol library reference, this ensures that all units are
modified by the same action and the component is not represented by its
subunits.
Fixes: lp:1834509
* https://bugs.launchpad.net/kicad/+bug/1834509
(cherry picked from commit 80e0d848f2)
They're now used for bus definition control characters.
Also fixes the sheet pin edit dialog to correctly escape/unescape
netnames.
Fixes: lp:1840834
* https://bugs.launchpad.net/kicad/+bug/1840834
Control ordering is critical to make dialog mnemonics work correct. The
static text with the mnemonic must immediately proceed the control and
no additional controls can be added between static text/control pair.
Fixing this required adding the units static text controls after all of
the mnemonic static text controls and their associated edit controls.
Mnemonics do not work for read only controls so all of the combobox
controls were moved after the text controls.
Fixes lp:1818930
https://bugs.launchpad.net/kicad/+bug/1818930
1) Add highlighting to simProbe and simTune tools.
2) Probe tool should accept wires and pins, not wires and components.
3) Give simulator window a flat look to match rest of Kicad.
4) Collapse whitespace out of simulator window.
5) Add some error messages.
6) Add some whitespace to simulation setting dialog.
Also rewrites the PCBNew Find dialog to make use of the above, including:
1) searching in user-defined footprint fields
2) searching in pcb text
3) a history list in the search popup
4) case sensitive searching
5) word sensitive searching
6) the ability to turn wildcard searching on/off
7) better placement of the result when the dialog obscures part of the
window
Fixes: lp:1838006
* https://bugs.launchpad.net/kicad/+bug/1838006
This changes make_lexer() so that it no longer generates a custom target
but instead attaches the generated files to an existing one (so the first
argument now is the name of an existing library or executable, and it needs
to come after the add_library/add_executable call).
The generated source is no longer listed in the project sources, as it is
added by the function. The files are generated in the build tree rather
than the source tree, and the directory is added to the include path for
the respective project as well as exported to projects linking against it.
Generated files in subdirectories are somewhat supported, but need to be
referenced with the same name as they were generated (i.e. including the
subdirectory name).
Fixes: lp:1831643
* https://bugs.launchpad.net/kicad/+bug/1831643
Fixes: lp:1832357
* https://bugs.launchpad.net/kicad/+bug/1832357
Fixes: lp:1833851
* https://bugs.launchpad.net/kicad/+bug/1833851
Prevent the symbol and footprint library table editors from substituting
the current project path (${KIPRJMOD}) when adding libraries to the global
library table. This will almost assuredly fail when opening a different
project. We still allow users to manually use ${KIPRJMOD} in global table
paths under the assumption that if they are typing this in then they most
likely understand environment variable substitution.
Fixes lp:1830694
https://bugs.launchpad.net/kicad/+bug/1830694
This adds the functionality to add multiple labels to your schematic at
once by using spaces in the original label name.
Fixes: lp:1095113
* https://bugs.launchpad.net/kicad/+bug/1095113
The grid apply code was always preventing empty fields. Change this the
broken behavior to allow any field to be empty except the reference and
value fields.
Fixes lp:1832722
https://bugs.launchpad.net/kicad/+bug/1832722
DIALOG_EXIT was not being laid out correctly after setting the dialog
message. Rather than fix our custom DIALOG_EXIT, wxMessageDialog and
wxRichMessageDialog were substituted as direct replacements for all
of the variants of DIALOG_EXIT. This make message dialogs appear more
consistent because wxMessageDialog uses the default platform message
dialog and wxRichMessageDialog uses the default platform rich message
dialog on windows.
Remove DIALOG_EXIT_BASE as it is no longer required.
Fixes lp:1832899
https://bugs.launchpad.net/kicad/+bug/1832899
A bug in LIB_MANAGER::LibraryExists() prevented a library removed from
the symbol library table from being removed from the tree view. Add the
proper check to SYMBOL_TREE_SYNCHRONIZING_ADAPTER::Sync().
This exposed another issue with synchronization between the library
table editor and the tree view which could lead to orphaned library
modifications and/or a segfault when the currently selected library was
removed from the symbol library table. Give the user a chance to save
or revert any changes before allowing changes to the symbol library
table.
Fixes lp:1821691
https://bugs.launchpad.net/kicad/+bug/1821691
These options were used to support the legacy canvas when drawing on
MacOS and GTK3. With the move to 100% GAL, they are extraneous. This
moves all DC over to "COPY" as we only use this for printing support in
Eeschema at the moment, so there is a single draw command (no erasing)
for the canvas.
Net names in eeschema that include '/' are escaped ('/' replaced by "{slash}")
Escaped netnames are only for internal use, and must be unescaped in spice netlist and dialogs.
It was escaped (replaced by "{slash}") in dialog.
This is right for labels, not for texts.
A consequence was the directives in spice simul can be broken.
Now the graphic text is not escaped.
This only applies to the root symbol when the datasheet field is not
empty and the datasheet for root symbol alias in the document file is
empty. Use the root symbol datasheet field value when adding a new
symbol that meets this criteria.
The root symbol datasheet field gets copied to the root symbol alias
datasheet member variable so if the symbol is modified and saved, the
datasheet information is saved in the .dcm file.
https://bugs.launchpad.net/kicad/+bug/1830078
Fixes lp:1830078
Prevent user from pasting text with carriage return and/or line feed
characters in field value edit control in the schematic symbol and symbol
library properties dialogs.
Make all objects derived from GRID_CELL_TEXT_BUTTON use validators
correctly.
Add validators to FIELDS_GRID_TABLE object for field values other than
the mandatory fields.
Create a validator to check that a string is a valid LIB_ID.
Fixes lp:1828214
https://bugs.launchpad.net/kicad/+bug/1828214
Force the symbol library links whenever the symbol library table has been
modified. This will use the cache as a fallback when a library has been
removed that contains links in the schematic rather than display.
Fix the SCH_COMPONENT symbol resolver when falling back to the cache. The
resolver was using the LIB_ID ':' notation which was failing. Replacing
':' with '_' fixed this issue. This was also an issue when generating the
symbol message panel information.
Convert wxLogDebug to wxLogTrace in symbol resolver code path. Add new
trace type KICAD_SYM_RESOLVE.
Fixes lp:1821606
https://bugs.launchpad.net/kicad/+bug/1821606
These dialogs had logic to avoid a table re-adjustment unless
the width changed. This was done to avoid spurious resizing
calls under GTK+3. This was commit
13249b723b, fixing bug lp:1817810.
However, by only calling event.Skip() when the width changed,
redraws were inhibited when only the height changed.
Placing the Skip() outside the width-change check fixes this,
and does not re-introduce the lp:1817810 bug (it is the column
adjust call that causes that).
Fixes: lp:1826615
* https://bugs.launchpad.net/kicad/+bug/1826615
In the component, an m_unit/m_convert element is 1-indexed as opposed to
the library where they are 0-indexed. The 0-index in the library is
reserved for those elements that are shared across all conversion/unit
whereas it is invalid for the component.
Fixes: lp:1824764
* https://bugs.launchpad.net/kicad/+bug/1824764
(cherry picked from commit c4be74a9d0)
When displaying a sheet from this path, it's possible the sheet will
not have been initialized yet. Call DisplayCurrentSheet() to make sure
it is initialized, and then call RedrawScreen to update the zoom level.
Fixes: lp:1824362
* https://bugs.launchpad.net/kicad/+bug/1824362
(cherry picked from commit 1c235a5c89)
Adjust the sizer proportions slightly to eliminate the reported bug.
This may not be the ideal way to do this and there could be some issues
on other platforms but it does resolve the issue on gtk3.
Fixes lp:1820084
https://bugs.launchpad.net/kicad/+bug/1820084
Bus upgrades: core new connectivity code
Bus upgrades: eeschema integration and modifications
Bus upgrades: eeschema dialogs
Bus upgrades: netlist export
Bus upgrades: file format changes
Make a few things const (specficially the reference into
m_fieldStore - we should commit to not modifying that in this
function.
Also avoid a couple of needless string copies.
Also explicitly dereference the into a (non-const) reference at the outset.
For the whole if this function, comp is the same object and may not
be null (as it is used unchecked).
Make the "Define as power symbol" checkbox tooltip more descriptive so
the user has a better understanding of enabling this option.
Fixes lp:1804932
https://bugs.launchpad.net/kicad/+bug/1804932
Call base object TransferDataFromWindow() to prevent Validate() from
being called twice. Validation is handled completely under the hood
so there is no need to call Validate() directly.
Fixes lp:1820301
https://bugs.launchpad.net/kicad/+bug/1820301
wxWidgets has several bugs that result in cell editors being closed
right after they're opened. There are two wxWidgets hacks to
partially address this: the SetInSetFocus() hack, and a slow-click
hack. We used to try and work-around these bugs ourselves for
single-click access, but this changelist moves those over to
wxWidget's slow-click hack.
Fixes: lp:1817965
* https://bugs.launchpad.net/kicad/+bug/1817965
The folder button handler works will for footprint libraries but we
needed a specific class for the schematic libraries as well.
Fixes: lp:1818346
* https://bugs.launchpad.net/kicad/+bug/1818346
For unknown reasons, GTK3 may send resize events when editing grid
fields. This can cause the grid editor to exit, losing the focus and
overwritting the characters at the next input.
We avoid this by filtering the size events when the size doesn't change.
Fixes: lp:1817810
* https://bugs.launchpad.net/kicad/+bug/1817810
Introduce a shortcut method to set tab ordering and use it in
the dialogs that override the tab traversal orders:
* Eeschema sheet properties
* Pcbnew Move exact
* Pcbnew Move relative
Also set some initial focus fields in the same dialogs.
Tidy a few includes.
Fixes: lp:1816009
* https://bugs.launchpad.net/kicad/+bug/1816009
Move the class DIALOG_EDIT_COMPONENT_IN_SCHEMATIC to its own
header, and move the SCH_EDIT_FRAME::EditComponent out of the
dialog implementation file. Thus, users of the dialog are
coupled only by the dialog header, as usual.
Also tidy some includes and comments.
In DIALOG_EDIT_COMPONENT_IN_SCHEMATIC, the Cancel button is
connected to a dedicated handler to deal with the footprint
browser widget. DIALOG_EDIT_COMPONENT_IN_LIBRARY should have
the same logic.
Fixes: lp:1816636
* https://bugs.launchpad.net/kicad/+bug/1816636
Click to add/edit footprint filters under MSW requires handling the
listbox double click first before the item is handled.
Fixes: lp:1816182
* https://bugs.launchpad.net/kicad/+bug/1816182